97 resultados para pharmaceutical supply
Resumo:
We investigate the dynamics of a Duffing oscillator driven by a limited power supply, such that the source of forcing is considered to be another oscillator, coupled to the first one. The resulting dynamics come from the interaction between both systems. Moreover, the Duffing oscillator is subjected to collisions with a rigid wall (amplitude constraint). Newtonian laws of impact are combined with the equations of motion of the two coupled oscillators. Their solutions in phase space display periodic (and chaotic) attractors, whose amplitudes, especially when they are too large, can be controlled by choosing the wall position in suitable ways. Moreover, their basins of attraction are significantly modified, with effects on the final state system sensitivity. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
In this work a switching feedback controller for stick-slip compensation of a 2-DOF mass-spring-belt system which interacts with an energy source of limited power supply (non-ideal case) is developed. The system presents an oscillatory behavior due to the stick-slip friction. As the system equilibrium for a conventional feedback controller is not the origin, a switching control law combining a state feedback term and a discontinuous term is proposed to regulate the position of the mass. The problem of tracking a desired periodic trajectory is also considered. The feedback system is robust with respect to the friction force that is assumed to be within known upper and lower bounds.
Resumo:
Tuned liquid column dampers are U-tubes filled with some liquid, acting as an active vibration damper in structures of engineering interest like buildings and bridges. We study the effect of a tuned liquid column damper in a vibrating system consisting of a cart which vibrates under driving by a source with limited power supply (non-ideal excitation). The effect of a liquid damper is studied in some dynamical regimes characterized by coexistence of both periodic and chaotic motion. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
We proposed a simple feedback control method to suppress chaotic behavior in oscillators with limited power supply. The small-amplitude controlling signal is applied directly to the power supply system, so as to alter the characteristic curve of the driving motor. Numerical results are presented showing the method efficiency for a wide range of control parameters. Moreover, we have found that, for some parameters, this kind of control may introduce coexisting periodic attractors with complex basins of attraction and, therefore, serious problems with predictability of the final state the system will asymptote to. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
We investigate numerically the dynamical behavior of a non-ideal mechanical system consisting of a vibrating cart containing a particle which can oscillate back and forth colliding with walls carved in the cart. This system represents an impact damper for controlling high-amplitude vibrations and chaotic motion. The motion of the cart is induced by an in-board non-ideal motor driving an unbalanced rotor. We study the phase space of the cart and the bouncing particle, in particular the intertwined smooth and fractal basin boundary structure. The control of the chaotic motion of the cart due to the particle impacts is also investigated. Our numerical results suggests that impact dampers of small masses are effective to suppress chaos, but they also increase the final-state sensitivity of the system in its phase space. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
Many water-supply systems in South America utilize the waters of the Guarani aquifer at least as part of their networks. However, there is little present knowledge in Brazil of the factors affecting Rn presence in the water supplied for end-users, despite the economic importance of Guarani aquifer. Rn-222 analyzes of 162 water samples were performed at 8 municipalities in São Paulo State, Brazil, with the aim of investigating the major factors affecting its presence in solution. The Rn-222 activity concentration ranged from 0.04 up to 204.9 Bq/L, with three samples exceeding the World Health Organization maximum limit of 100Bq/L. Aeration was confirmed as the most important factor for Rn release, as expected due to its gaseous nature. Accumulation in pipes and stratification in the water column were other significant factors explaining the data obtained in some circumstances. The Rn daughters Ph-214 and Bi-214 were also determined in a set of selected samples and their presence was directly related to the occurrence of Rn dissolved in water. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes an analytical reflectometric method that has an objective not only the industrial quality control but also to detect possible falsifications and/or adulterations of propranolol in pharmaceutical formulations. The method is based on the diffuse reflectance measurements of the colored product (III) of the spot test reaction between propranolol hydrochloride (I) and 2,6-dichloroquinone-4-chloroimide (II) using filter paper as solid support. Spot test conditions have been investigated using experimental design in order to identify and optimize the critical factors. The factors evaluated were DCQ concentration, propranolol solvent and DCQ solvent. The best reaction conditions were achieved with the addition of 30 mu L, of propranolol solution in ethanol 35% (v/v) and 30 mu L of DCQ solution at 70 mg mL(-1) in acetone, in this order. All reflectance measurements were carried out at 500 nm and the linear range was from 8.45 x 10(-4) to 8.45 x 10(-2) mol L-1 (r= 0.998). The limit of detection was 1.01 x 10(-4) mol L-1. No interference was observed from the assessed excipients and drugs. The method was applied to determine propranolol in commercial brands of pharmaceuticals. The results obtained by the proposed method were favorably compared with those given by the British Pharmacopoeia procedure. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A flow-injection (FI) spectrophotometric procedure exploiting merging zones is proposed for the determination of azithromycin in pharmaceutical formulations. The method is based on the reaction of azithromycin with tetrachloro-phenzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in a methanol medium, producing a purple-red color compound (lambda(max) = 540 nm). The FI system and the experimental conditions were optimized using a multivariate method. Beer's law is obeyed in a concentration range of 50 - 1600 mu g mL(-1) with an excellent correlation coefficient (r = 0.9998). The detection limit and the quantification limit were 6.6 and 22.1 mu g mL(-1), respectively. No interference was observed from the common excipients, and the recoveries were within 98.6 to 100.4%. The procedure was applied to the determination of azithromycin in pharmaceuticals with a high sampling rate (65 samples h(-1)). The results obtained by the proposed method were in good agreement with those obtained by the comparative method at 95% confidence level.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(FF)(2)vertical bar Graphite, where FF stands for flufenamate ion, are described. This electrode responds to FF with sensitivity of (-58.6 +/- 1.2) mV decade(-1) over the range 1.0 x 10(-6) - 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 7.1 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 5 months without any considerable change in its performance characteristics. The proposed electrode displayed good selectivity for flufenamate in the presence of several substances as well as in the presence of some carboxylate and inorganic anions. The electrode was successfully applied to the determination of flufenamic acid in pharmaceuticals and human serum samples.