84 resultados para leakage losses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional Newton's method is considered to be inadequate for the computation of the maximum loading point (MLP) of power systems since: (i) it encounters difficulties in the vicinity of the MLP: and (ii) the load flow Jacobian matrix becomes singular at the MLP. It is well known that continuation methods are powerful and useful tools that are able to trace the solution PV curve without experiencing such diffculties. However, continuation methods require a parameterisation so that a modified, well conditioned set of load flow equations is obtained. In particular, the Jacobian matrix associated with this modified set of equations should not be singular at the MLP. The authors propose that the actual power losses in transmission branches (lines and transformers) are used to parameterise the approach. Specific procedures for the automatic determination of the most appropriate parameter (branch) are proposed. Such procedures include the utilisation of fast voltage-stability indices. Simulation results are presented to show that the proposed method is able to trace the whole solution PV curve very efficiently.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BaBi2Ta2O9 thin films having a layered structure were fabricated by metalorganic solution deposition technique. The films exhibited good structural, dielectric, and insulating properties. The room temperature resistivity was found to be in the range of 10(12)-10(14) Omega cm up to 4 V corresponding to a field of 200 kV/cm across the capacitor for films annealed in the temperature range of 500-700 degrees C. The current-voltage (I-V) characteristics as a function of thickness for films annealed at 700 degrees C for 1 h, indicated bulk limited conduction and the log(I) vs V-1/2 characteristics suggested a space-charge-limited conduction mechanism. The capacitance-voltage measurements on films in a metal-insulator-semiconductor configuration indicated good Si/BaBi2Ta2O9 interface characteristics and a SiO2 thickness of similar to 5 nm was measured and calculated. (C) 1999 American Institute of Physics. [S0003-6951(99)00830-X].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on pressure drop were obtained in stainless steel, sanitary fittings and valves during laminar and turbulent flow of aqueous suspensions of sucrose and bentonite. The rheological properties of these suspensions were determined and the Bingham model provided the best fitting with the experimental data. Friction losses were measured in fully- and partially-open butterfly and plug valves, bends and union. Values of loss coefficients (k(f)) were calculated and correlated as functions of the classical Reynolds number and the Reynolds number proposed by Govier and Aziz (1972) for viscoplastic fluids. The two-k method and a new proposed model presented the best adjustments for the Govier and Aziz Reynolds number, and Hedstrom and classical Reynolds numbers, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the performance of six major methods of loss allocation for generators and demands was conducted, based on pro-rata (two), on incremental factors (two), on proportional sharing (PS) (one), and on electric circuit theory (one). Using relatively simple examples which can easily be checked, the advantages and disadvantages of each were ascertained and the results confirmed using a larger sample system (IEEE-118). The discussion considers the location and size of generators and demands, as well as the merits of the location of these agents for each configuration based on an analysis of the effect of various network modifications. Furthermore, an application in the South-Southeastern Brazilian Systems is performed. Conclusions and recommendations are presented. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glasses in PbGeO3-PbF-CdF2 and GeO2-PbO-PbF2-CdF2 systems were studied and the fluorine losses during synthesis were investigated. Samples were characterized by differential scanning calorimetry (DSC), X-ray diffraction, Fourier transform infrared spectroscopy (FTIR) and Raman scattering spectroscopy. The use of stoichiometric germanate glass, PbGeO3, instead of introducing individual oxides (GeO2 + PbO) lead to decreasing fluorine losses, as detected by a fluorine ion selective electrode. The main structural features obtained from vibrational spectroscopy could be described by a metagermanate basic structure permeating fluorine rich regions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes a novel neural model to estimate electrical losses in transformer during the manufacturing phase. The network acts as an identifier of structural features on electrical loss process, so that output parameters can be estimated and generalized from an input parameter set. The model was trained and assessed through experimental data taking into account core losses, copper losses, resistance, current and temperature. The results obtained in the simulations have shown that the developed technique can be used as an alternative tool to make the analysis of electrical losses on distribution transformer more appropriate regarding to manufacturing process. Thus, this research has led to an improvement on the rational use of energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ferroelectric properties and leakage current mechanisms of preferred oriented Bi3.25La0.75Ti3O12 (BLT) thin films deposited on La0.5Sr0.5CoO3 by the polymeric precursor method were investigated. These films showed excellent ferroelectric properties in terms of large remnant polarization (2P(r)) of 47.6 mu C/cm(2) and (2E(c)) of 55 kV/cm, fatigue-free characteristics up to 10(10) switching cycles, and a current density of 0.7 mu A/cm(2) at 10 kV/cm. X-ray diffraction and scanning electron microscope investigations indicate that the deposited films exhibit a dense, well-crystallized microstructure having random orientations and with a rather smooth surface morphology. The improved ferroelectric and leakage current characteristics can be ascribed to the platelike grains of the BLT films, which make the domain walls easier to be switched under external field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the studied region, 35% of the soil collapses are related to leakage from sewage ducts. The paper describes the soils from this part of Brazil and a series of laboratory tests undertaken using water and domestic sewage fluid as the wetting agents. It is considered that the presence of soaps and detergents as recorded by the sodium concentration facilitates the densification of the soils and hence has a major effect on the surface settlement/collapse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To evaluate the reactivity of different endodontic materials and sealers with glucose and to asses the reliability of the glucose leakage model in measuring penetration of glucose through these materials.Methodology Ten uniform discs (radius 5 mm, thickness 2 mm) were made of each of the following materials: Portland cement, MTA (grey and white), sealer 26, calcium sulphate, calcium hydroxide [Ca(OH)(2)], AH26,Epiphany, Resilon, gutta-percha and dentine. After storing the discs for 1 week at 37 degrees C and humid conditions, they were immersed in 0.2 mg mL(-1) glucose solution in a test tube. The concentration of glucose was evaluated using an enzymatic reaction after 1 week. Statistical analysis was performed with the ANOVA and Dunnett tests at a significant level of P < 0.05.Results Portland cement, MTA, Ca(OH)(2) and sealer 26 reduced the concentration in the test tube of glucose significantly after 1 week (P < 0.05). Calcium sulphate reduced the concentration of glucose, but the difference in concentrations was not significant (P = 0.054).Conclusions Portland cement, MTA, Ca(OH)(2) and sealer 26 react with a 0.2 mg mL(-1) glucose solution. Therefore, these materials should not be evaluated for sealing ability with the glucose leakage model.