196 resultados para frequency.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the use of para-orthogonal polynomials in solving the frequency analysis problem. Through a transformation of Delsarte and Genin, we present an approach for the frequency analysis by using the zeros and Christoffel numbers of polynomials orthogonal on the real line. This leads to a simple and fast algorithm for the estimation of frequencies. We also provide a new method, faster than the Levinson algorithm, for the determination of the reflection coefficients of the corresponding real Szego polynomials from the given moments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar a prevalência e frequência de cefaléia em escolares brasileiros. Um estudo transversal foi conduzido entre Março e Novembro de 2004 em São José do Rio Preto, Estado de São Paulo, Brasil. Uma amostra de 5.232 crianças das escolas foi selecionada utilizando método de amostragem estratificada proporcional. Para a coleta dos dados, um questionário foi entregue nas escolas aos estudantes para ser respondida pelos pais e/ou responsáveis. do total de respostas recebidas, 84,2% relataram cefaléia durante o último ano. Houve diferenças significativas na frequência da queixa de cefaléia entre meninos e meninas. As meninas relataram cefaléias mais frequentes do que os meninos, com prevalência de cefaléias diárias duas vezes maior em meninas. Uma maior frequência de cefaléia foi também relatada com o aumento da idade. O estudo demonstrou que a prevalência de cefaléia foi alta, com uma maior frequência (mensais, semanais e diárias) em meninas e no grupo etário mais velho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report results of a study of the B-s(0) oscillation frequency using a large sample of B-s(0) semileptonic decays corresponding to approximately 1 fb(-1) of integrated luminosity collected by the D0 experiment at the Fermilab Tevatron Collider in 2002-2006. The amplitude method gives a lower limit on the B-s(0) oscillation frequency at 14.8 ps(-1) at the 95% C.L. At Delta m(s)=19 ps(-1), the amplitude deviates from the hypothesis A=0 (1) by 2.5 (1.6) standard deviations, corresponding to a two-sided C.L. of 1% (10%). A likelihood scan over the oscillation frequency, Delta m(s), gives a most probable value of 19 ps(-1) and a range of 17

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the mid 1980s the Atomic Force Microscope is one the most powerful tools to perform surface investigation, and since 1995 Non-Contact AFM achieved true atomic resolution. The Frequency-Modulated Atomic Force Microscope (FM-AFM) operates in the dynamic mode, which means that the control system of the FM-AFM must force the micro-cantilever to oscillate with constant amplitude and frequency. However, tip-sample interaction forces cause modulations in the microcantilever motion. A Phase-Locked loop (PLL) is used to demodulate the tip-sample interaction forces from the microcantilever motion. The demodulated signal is used as the feedback signal to the control system, and to generate both topographic and dissipation images. As a consequence, a proper design of the PLL is vital to the FM-AFM performance. In this work, using bifurcation analysis, the lock-in range of the PLL is determined as a function of the frequency shift (Q) of the microcantilever and of the other design parameters, providing a technique to properly design the PLL in the FM-AFM system. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A introdução do mesilato de imatinibe como tratamento da leucemia mielóide crônica tem salvado muitos pacientes, mas o sucesso da terapia tem sido prejudicado pela resistência e possível não destruição do clone maligno. Este artigo descreve a resposta citogenética e padrões citogenéticos anormais envolvendo os genes ABL e BCR detectados por FISH em pacientes em uso exclusivo de imatinibe. Os resultados mostraram que outras alterações envolvendo os genes BCR e ABL não parecem estar relacionadas à resistência à droga, elas ocorrem em baixas freqüências e podem não estar associadas à resposta citogenética ou ao tempo de tratamento. Contudo, a resposta ao imatinibe parece ser individual e imprevisível, independente do tempo e do início do tratamento após o diagnóstico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)