102 resultados para Weld bead
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this study a pulsed Nd:YAG laser was used to join Monel 400 thin foil with 100 mu m thickness. Pulse energy was varied from 1.0 to 2.25J at small increments of 0.25J. The macro and microstructures were analyzed by optical microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the bottom foil dilution rate, it is possible to weld Monel 400 thin foil. The process appeared to be very sensitive to the gap between couples.
Resumo:
In this study a pulsed Nd:YAG laser was used to join Hastelloy C-276 thin foil with 100 microns thickness. Pulse energy was varied from 1.0 to 2.25 J at small increments of 0.25 J with a 4 ms pulse duration. The macro and microstructures of the welds were analyzed by optical and electronic microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the dilution rate, it is possible to weld Hastelloy C-276 thin foil by pulsed Nd: YAG laser. (C) 2012 Published by Elsevier B. V. Selection and/or review under responsibility of Bayerisches Laserzentrum GmbH
Resumo:
Although the prevalence of caries has decreased dramatically over the past decades, it has become a polarised disease, with most of subjects presenting low caries levels and few individuals accounting for most of the caries affected surfaces. Thus it become evident for the need of clinical approaches directed at these high-risk patients, in order to overcome problems related to compliance and low attendance at dental care centres. Slow-release fluoride devices were developed based on the inverse relationship existing between intra-oral fluoride levels and dental caries experience. The two main types of slow-release devices - copolymer membrane type and glass bead - are addressed in the present review. A substantial number of studies have demonstrated that these devices are effective in raising intra-oral F concentrations at levels able to reduce enamel solubility, resulting in a caries-protective effect. Studies in animals and humans demonstrated that the use of these devices was able to also protect the occlusal surfaces, not normally protected by conventional fluoride regimens. However, retention rates have been shown to be the main problem related to these devices and still requires further improvements. Although the results of these studies are very promising, further randomised clinical trials are needed in order to validate the use of these devices in clinical practice. The concept of continuously providing low levels of intra-oral fluoride has great potential for caries prevention in high caries-risk groups.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Foram realizados estudos para avaliar a microestrutura, a dureza e a resistência à corrosão do titânio comercialmente puro-Ti c.p. soldado por laser e utilizado na confecção de prótese sobre implantes. Verificou-se que na soldagem a laser a microestrutura apresentou três regiões distintas: o cordão de solda, a zona afetada pelo calor - ZAC e o metal base. O Ti c.p. possui microestrutura granular, a microestrutura do cordão de solda é mais refinada e de maior dureza do que o metal base. A ZAC obtida por este processo de soldagem foi relativamente pequena quando comparada com o processo de soldagem por brasagem. Os ensaios eletroquímicos mostraram que a região da solda apresentou menor resistência à corrosão em meio de NaCl 0,15 molL-1 à temperatura ambiente.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo deste trabalho foi verificar quanto tempo após a realização da enxertia hipocotiledonar ocorre a soldadura ou adesão entre enxerto e porta-enxerto, e também a formação da ponte de calo, verificada pelo total preenchimento da fenda por tecido meristemático secundário (calo). Foram produzidas 56 mudas de maracujazeiro-amarelo (Passiflora edulis Sims f. flavicarpa Deg.) pela enxertia hipocotiledonar em fenda cheia no topo sobre dois porta-enxertos (P. edulis Sims f. flavicarpa Deg. e P. alata Dryander). Aos 0, 3, 6, 9, 12, 15 e 18 dias após a enxertia, coletou-se a região da enxertia de quatro mudas de cada combinação. O material coletado foi fixado em solução de glutaraldeído a 3%, pós-fixado em tetróxido de ósmio a 2%, desidratado em uma série de álcool etílico (30, 40, 50, 60, 70, 80, 90, 100%), levado ao secador de ponto crítico (CO2), montado, metalizado com ouro - paládio (35 nm) e, por fim, observados e eletromicrografados em microscópio eletrônico de varredura JEOL JSM 5410 (operado em 15 kV). Verificou-se que, aos seis dias após a enxertia, a soldadura para o porta-enxerto Passiflora alata já havia ocorrido, o que só foi constatado para Passiflora edulis f. flavicarpa aos nove dias. Também, aos nove dias, observou-se para ambos os porta-enxertos a completa formação da ponte de calo, indicando que, a partir daí, pode-se iniciar o processo de aclimatação da muda, para levá-la a um ambiente de menor umidade.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Resin solvation properties affect the efficiency of the coupling reactions in solid-phase peptide synthesis. Here we report a novel approach to evaluate resin solvation properties, making use of spin label electron paramagnetic resonance (EPR) spectroscopy. The aggregating VVLGAAIV and ING sequences were assembled in benzhydrylamine-resin with different amino group contents (up to 2.6 mmol/g) to examine the extent of chain association within the beads. These model peptidyl-resins were first labeled at their N-terminus with the amino acid spin label 2,2,6,6-tetramethylpiperidine-N-oxyl-4-amino-4-carboxylic acid (Toac). Their solvation properties in different solvents were estimated, either by bead swelling measurement or by assessing the dynamics of their polymeric matrixes through the analysis of Toac EPR spectra, and were correlated with the yield of the acylation reaction. In most cases the coupling rate was found to depend on bead swelling. Comparatively, the EPR approach was more effective. Line shape analysis allowed the detection of more than one peptide chain population, which influenced the reaction. The results demonstrated the unique potential of EPR spectroscopy not only for improving the yield of peptide synthesis, even in challenging conditions, but also for other relevant polymer-supported methodologies in chemistry and biology.
Resumo:
[GRAPHICS]This work proposes a combined swelling-electron paramagnetic resonance (EPR) approach aiming at determining some unusual polymer solvation parameters relevant for chemical processes occurring inside beads. Batches of benzhydrylamine-resin (BHAR), a copolymer of styrene-1% divinylbenzene containing phenylmethylamine groups were, labeled with the paramagnetic amino acid 2,2,6,6-tetramethylpiperidine-1-oxyl-4-amine-4-carboxylic acid (TOAC), and their swelling properties and EPR spectra were examined in DCM and DMF. By taking into account the BHARs labeling degrees, the corresponding swelling values, and some polymer structural characteristics, it was possible to calculate polymer swelling parameters, among them, the volume and the number of sites per bead, site-site distances and site concentration. The latter values ranged from 17 to 170 angstrom and from 0.4 to 550 mM, respectively. EPR spectroscopy was applied to validate the multistep calculation strategy of these swelling parameters. Spin-spin interaction was detected in the labeled resins at site-site distances less than approximately 60 A or probe concentrations higher than approximately 1 x 10(-2) M, in close agreement with the values obtained for the spin probe free in solution. Complementarily, the yield of coupling reactions in different resins indicated that the greater the inter-site distance or the lower the site concentration, the faster the reaction. The results suggested that the model and the experimental measurements developed for the determination of solvation parameters represent a relevant step forward for the deeper understanding and improvement of polymer-related processes.
Resumo:
Background: Canine hip dysplasia (HD) is characterized by hip joint laxity and subluxation. It is the most common cause of osteoarthritis in dogs, especially in larger breeds. Its management includes nutritional supplements, nonsteroidal anti-inflammatory drugs, physical therapy, acupuncture or surgical procedures. Implantation of gold beads in acupuncture points and trigger points around a joint has been used in the treatment of osteoarthritis in dogs for at least 30 years. Gold bead implants(GBI) acts as continuous acupuncture stimulation and trigger point treatment in canine HD with long lasting results. Electrophysiological investigations of trigger points reveal dysfunctional muscle spindles which indicate that the electrical activity of active loci arises from extrafusal motor endplates.Case: This is a report on the use of acupuncture and GBI for bilateral HD in a nine year old female German Shepherd. The patient has a HD non-responsive to anti-inflammatory drugs and was unable to stand up or walk by its own. Radiographs showed marked dysplasia, significant subluxation with the femoral head partly out of a shallow acetabulum and massive secondary arthritic bone changes, mainly on the right side. The animal was submitted to eight acupuncture sessions with seven days interval. After the first acupuncture session the use of NSAID was interrupted. After eight weeks the dog was considered rehabilitated and underwent GBI in acupoints and trigger points as maintenance treatment. During the one-year follow-up period the improvement remained unchanged with no need of analgesics.Discussion: It has been suggested that acupuncture or GBI can treat the chronic pain resulting from osteoarthritis induced by HD. According to AP theory, GBI is permanent and long-lasting acupoint stimulation. Moreover, the method is inexpensive, quick and easy to perform, with no postoperative pain or need of exercise restriction. Although gold is extremely corrosion-resistant, the surface of the gold implants stimulates a reaction from the immune system causing an oxidative liberation of gold ions with anti-inflammatory actions. It is well known that gold ions are effective inhibitors of the respiratory burst of neutrophils and monocytes and the proliferation of lymphocytes. These findings suggest that gold implantation, on a local scale, mimics the anti-inflammatory and pain-relieving effect of drugs with chemically bound gold ions. The relatively slow speed of the process results in a limited liberation of gold ions securing that they are taken up almost exclusively by cells close to the implant. The nine year old female German shepherd had a positive response to acupuncture with pain relieve and locomotor rehabilitation. For the nine year old female German shepherd previous acupuncture sessions to GBI resulted in no post-implant worsening period. Indeed, the association acupuncture/GBI does not have the anti-inflammatory drugs undesirable effects and brings long lasting results. In conclusion, GBI therefore should be considered for canine HD when conservative or medical treatments fail to give the desired effect.
Resumo:
Intense inflammatory response and an anti-angiogenic state have been implicated in the pathogenesis of preeclampsia. Here, we investigated this hypothesis evaluating the serum concentrations of CXCL10/IP-10, sFlt-1, and PlGF in women with early-onset preeclampsia. CXCL10/IP-10 was measured by Cytometric Bead Array. sFlt-1 and PlGF were measured by automated electrochemiluminescence immunoassay. The median serum concentration of CXCL10/IP-10 was 109.5 pg/mL in preeclamptic women, as compared with 52.28 pg/mL in the controls (P = 0.0028). The mean serum level of sFlt-1 was 13,636 pg/mL in preeclamptic women, as compared with 2020 pg/mL in the controls (P < 0.0001). PlGF levels were significantly lower in women with preeclampsia. © 2011 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.