106 resultados para Steady state migration test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO:Relatar o caso de um lactente com citomegalovírus congênito e disacusia neurossensorial progressiva, analisado por três métodos de avaliação auditiva.DESCRIÇÃO DO CASO:Na primeira avaliação auditiva, aos quatro meses de idade, o lactente apresentou ausência de Emissões Otoacústicas (EOA) e Potencial Evocado Auditivo de Tronco Encefálico (PEATE) dentro dos padrões de normalidade para a faixa etária, com limiar eletrofisiológico em 30dBnHL, bilateralmente. Com seis meses, apresentou ausência de PEATE bilateral em 100dBnHL. A avaliação comportamental da audição mostrou-se prejudicada devido ao atraso no desenvolvimento neuropsicomotor. Aos oito meses, foi submetido ao exame de Resposta Auditiva de Estado Estável (RAEE) e os limiares encontrados foram 50, 70, ausente em 110 e em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à direita, e 70, 90, 90 e ausente em 100dB, respectivamente para 500, 1.000, 2.000 e 4.000Hz, à esquerda.COMENTÁRIOS:Na primeira avaliação, o lactente apresentou alteração auditiva no exame de EOA e PEATE normal, que passou a ser alterado aos seis meses de idade. A intensidade da perda auditiva só pôde ser identificada pelo exame de RAEE, permitindo estabelecer a melhor conduta na adaptação de aparelho de amplificação sonora individual. Ressalta-se a importância do acompanhamento audiológico para crianças com CMV congênito.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The steady-state average run length is used to measure the performance of the recently proposed synthetic double sampling (X) over bar chart (synthetic DS chart). The overall performance of the DS X chart in signaling process mean shifts of different magnitudes does not improve when it is integrated with the conforming run length chart, except when the integrated charts are designed to offer very high protection against false alarms, and the use of large samples is prohibitive. The synthetic chart signals when a second point falls beyond the control limits, no matter whether one of them falls above the centerline and the other falls below it; with the side-sensitive feature, the synthetic chart does not signal when they fall on opposite sides of the centerline. We also investigated the steady-state average run length of the side-sensitive synthetic DS X chart. With the side-sensitive feature, the overall performance of the synthetic DS X chart improves, but not enough to outperform the non-synthetic DS X chart. Copyright (C) 2014 John Wiley &Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize the thresholds of the auditory steady-state response that relates to term newborns and infants. Design: The study was cross-sectional using auditory steadystate response assessment, and the real-ear-to-dial difference was measured in the external auditory canal. Study Sample: The study group included 60 newborns and infants between the age of 0 and 6 months. Results: A statistically significant difference was found in the carrier frequency variable for auditory steady-state response thresholds but not in comparison to ages. Furthermore, there is an association between auditory steady-state response thresholds and the real-ear-to-dial difference. Conclusion: The same threshold can be used as a normality reference for this age range, with distinct values for the different carrier frequencies. The influence of external auditory canal amplification should be taken into account.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming model to solve the conductor size selection and reconductoring problem in radial distribution systems. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. The proposed model and a heuristic are used to obtain the Pareto front of the conductor size selection and reconductoring problem considering two different objective functions. The results of one test system and two real distribution systems are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. © 1969-2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming approach to solving the problem of optimal type, size and allocation of distributed generators (DGs) in radial distribution systems. In the proposed formulation, (a) the steady-state operation of the radial distribution system, considering different load levels, is modeled through linear expressions; (b) different types of DGs are represented by their capability curves; (c) the short-circuit current capacity of the circuits is modeled through linear expressions; and (d) different topologies of the radial distribution system are considered. The objective function minimizes the annualized investment and operation costs. The use of a mixed-integer linear formulation guarantees convergence to optimality using existing optimization software. The results of one test system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique.© 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tegtbur et al. [23] devised a new method able to estimate the intensity at maximal lactate steady state termed lactate minimum test. According to Billat et al. [7], no studies have yet been published on the affect of training on highest blood lactate concentration that can be maintained over time without continual blood lactate accumulation. Therefore, the aim of the present study was to verify the effect of soccer training on the running speed and the blood lactate concentration (BLC) at the lactate minimum test (Lac(min)). Thirteen Brazilian male professional soccer players, all members of the same team playing at National level, volunteered for this study. Measurements were carried out before (pre) and after (post) eight weeks of soccer training. The Lac(min) test was adapted to the procedures reported by Tegtbur et al. [23]. The running speed at the Lac(min) test was taken when the gradient of the line was zero. Differences in running speed and blood lactate concentration at the Lac(min) test before (pre) and after (post) the training program were evaluated by Student's paired t-test. The training program increased the running speed at the Lac(min) test (14.94 +/- 0.21 vs. 15.44 +/- 0.42* km(.)h(-1)) and the blood lactate concentration (5.11 +/- 2.31 vs. 6.93 +/- 1.33* mmol(.)L(-1)). The enhance in the blood lactate concentration may be explained by an increase in the lactate/H+ transport capacity of human skeletal muscle verified by other authors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The break point of the curve of blood lactate vs exercise load has been called anaerobic threshold (AT) and is considered to be an important indicator of endurance exercise capacity in human subjects. There are few studies of AT determination in animals. We describe a protocol for AT determination by the lactate minimum test in rats during swimming exercise. The test is based on the premise that during an incremental exercise test, and after a bout of maximal exercise, blood lactate decreases to a minimum and then increases again. This minimum value indicates the intensity of the AT. Adult male (90 days) Wistar rats adapted to swimming for 2 weeks were used. The initial state of lactic acidosis was obtained by making the animals jump into the water and swim while carrying a load equivalent to 50% of body weight for 6 min (30-s exercise interrupted by a 30-s rest). After a 9-min rest, blood was collected and the incremental swimming test was started. The test consisted of swimming while supporting loads of 4.5, 5.0, 5.5, 6.0 and 7.0% of body weight. Each exercise load lasted 5 min and was followed by a 30-s rest during which blood samples were taken. The blood lactate minimum was determined from a zero-gradient tangent to a spline function fitting the blood lactate vs workload curve. AT was estimated to be 4.95 ± 0.10% of body weight while interpolated blood lactate was 7.17 ± 0.16 mmol/l. These results suggest the application of AT determination in animal studies concerning metabolism during exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lactate minimum test (LACmin) has been considered an important indicator of endurance exercise capacity and a single session protocol can predict the maximal steady state lactate (MLSS). The objective of this study was to determine the best swimming protocol to induce hyperlactatemia in order to assure the LACmin in rats (Rattus norvegicus), standardized to four different protocols (P) of lactate elevation. The protocols were PI: 6 min of intermittent jumping exercise in water (load of 50% of the body weight - bw); P2: two 13% bw load swimming bouts until exhaustion (thin); P3: one thin 13% bw load swimming bout; and P4: two 13% bw load swimming bouts (1st 30 s, 2nd to thin), separated by a 30 s interval. The incremental phase of LACmin beginning with initial loads of 4% bw, increased in 0.5% at each 5 min. Peak lactate concentration was collected after 5, 7 and 9 min (mmol L-1) and differed among the protocols P 1 (15.2 +/- 0.4, 14.9 +/- 0.7, 14.8 +/- 0.6) and P2 (14.0 +/- 0.4, 14.9 +/- 0.4, 15.5 +/- 0.5) compared to P3 (5.1 +/- 0.1, 5.6 +/- 0.3, 5.6 +/- 0.3) and P4 (4.7 +/- 0.2, 6.8 +/- 0.2, 7.1 +/- 0.2). The LACmin determination success rates were 58%, 55%, 80% and 91% in P1, P2, P3 and P4 protocols, respectively. The MLSS did not differ from LACmin in any protocol. The LACmin obtained from P4 protocol showed better assurance for the MLSS identification in most of the tested rats. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to describe a double-bout exercise test for non-exhaustive aerobic capacity determination in swimming rats. Adult rats were Submitted to 4 swimming tests at different intensities (4%, 6%, 7%, and 8% of body mass), with intervals of 48 h between them. Two exercise bouts of equal intensity lasting 5 min were performed, separated by 2 min with blood collection for lactate analysis. For each intensity, delta lactate was determined by subtracting lactate concentration at the end of the first effort from the lactate at the end of the second effort. Individual linear interpolation of delta lactate concentration enabled determination of a null delta, equivalent to the critical load (CL). Maxima) lactate steady state (MLSS) was also determined. The estimated CL was of 4.8% body mass and the MLSS was observed at 100% of CL, with blood lactate of 5.20 mmol/L. At 90%, blood lactate stabilized, with a progressive increase to 110% CL. These results offer a potential determination of aerobic capacity in swimming rats.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Injection metering systems are an important option for the development of pesticide application equipment, with advantages relating to minimising the need for disposal of unused pesticide, improving the ease of cleaning and optimising the accuracy of chemical application. For all injection systems, characteristics such as the steady-state accuracy of delivered dose, dose stability and the time response for dose step changes are related to the ability of the system to operate with different chemical formulations. A system designed to inject liquids should be able to accommodate changes in viscosity and density. The aim of this study was to develop a methodology for testing chemical injection systems using liquids with different viscosities. The experimental arrangement simulating applications with injection metering systems used dye and salt solutions as tracers. Tests were conducted to analyse the influence of salt on the characteristics of the water and a viscous solution. Results showed that the salt interfered with the dye stability in the water solution. In tests with a viscous test liquid, the salt was introduced at different steps during the mixing process, providing four different liquids to be analysed in terms of viscosity, density and pH. Some differences in liquid characteristics were found which could influence the performance of the injection systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and applicable method for non-exhaustive aerobic evaluation in running rats is described. Wistar rats were submitted to running test at different velocities (10, 15, 20, 25 m/min) with 48 h recovery among them. At each velocity, the rats ran two bouts of 5 min with 2 min of rest between bouts. Blood samples were collected at the end of each bout for lactate determination. For each intensity, delta lactate was calculated and using deltas obtained by four tests, an individual linear interpolation was plotted. The y-intercept of linear interpolation was the null delta lactate equivalent to the critical velocity (CV). To verify the lactate stabilization at CV, the animals were submitted to 25 min of continuous exercise (15, 20, 25 m/min), with blood collection every 5 min. The estimated CV was 16.6±0.7 m/min, with significant linear regressions (R=0.90±0.03). The rats presented maximal lactate steady state (MLSS) at 3.9±0.4 mmol/L, at 20 m/min. The CV was less than MLSS but significantly correlated with this parameter (r=0.78). This non-exhaustive test seems to be valid for the aerobic evaluation of sedentary rats and this protocol underestimates the MLSS in 20%. This test seems to be the interesting method for the evaluation of rats submitted to acute exercise or physical training.