52 resultados para PROSTHODONTIC MAINTENANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cost of maintenance makes up a large part of total energy costs in ruminants. Metabolizable energy (ME) requirement for maintenance (MEm) is the daily ME intake that exactly balances heat energy (HE). The net energy requirement for maintenance (NEm) is estimated subtracting MEm from the HE produced by the processing of the diet. Men cannot be directly measured experimentally and is estimated by measuring basal metabolism in fasted animals or by regression measuring the recovered energy in fed animals. MEm and NEm usually, but not always, are expressed in terms of BW0.75. However, this scaling factor is substantially empirical and its exponent is often inadequate, especially for growing animals. MEm estimated by different feeding systems (AFRC, CNCPS, CSIRO, INRA, NRC) were compared by using dairy cattle data. The comparison showed that these systems differ in the approaches used to estimate MEm and for its quantification. The CSIRO system estimated the highest MEm, mostly because it includes a correction factor to increase ME as the feeding level increases. Relative to CSIRO estimates, those of NRC, INRA, CNCPS, and AFRC were on average 0.92, 0.86, 0.84, and 0.78, respectively. MEm is affected by the previous nutritional history of the animals. This phenomenon is best predicted by dynamic models, of which several have been published in the last decades. They are based either on energy flows or on nutrient flows. Some of the different approaches used were described and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. Materials and methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n=12). The crowns presented no misfit in Group A (control group) and unilateral misfits of 50μm, 100μm and 200μm in the groups B, C and D, respectively. The crowns were attached to external hexagon implants with a titanium retention screw with torque of 30N/cm. Oblique loading of 130N at 2Hz was applied on each replica, totalizing 5×104 and 1×106cycles. Detorque values were measured initially and after each cycling period. Data were evaluated by analysis of variance and Tukey's HSD test (p<0.05). Results: All groups presented reduced initial detorque values (p< 0.05) in comparison to the insertion torque (30. ± 0.5. N/cm) and Group A (25.18. N/cm) exhibited the lowest reduction. After mechanical cycling, all groups presented detorque values from 19.5. N/cm to 22.38. N/cm and the mechanical cycling did not statistically influence the detorque values regardless the misfit level of the replicas. Conclusion: The unilateral misfit influenced the preload maintenance only before mechanical cycling. The mechanical cycling did not influence the torque reduction. © 2010 Japan Prosthodontic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effects of maintenance therapy with or without the use of 0.12% chlorhexidine in the periodontal tissues of patients with diabetes mellitus who had carious lesions restored with composed resin. Twenty patients were selected, all of whom had diabetes mellitus in addition to carious cervical lesions in previously treated teeth. After 90 days, improvement in plaque and gingival indices and probing depth were noticed among patients in the group that received 0.12% chlorhexidine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of vibration analysis techniques based on virtual instrumentation has spread increasingly in the academic and industrial branch, since the use of any software for this type of analysis brings good results at low cost. Among the existing software for programming and creation of virtual instruments, the LabVIEW was chosen for this project. This software has good interface with the method of graphical programming. In this project, it was developed a system of rotating machine condition monitoring. This monitoring system is applied in a test stand, simulating large scale applications, such as in hydroelectric, nuclear and oil exploration companies. It was initially used a test stand, where an instrumentation for data acquisition was inserted, composed of accelerometers and inductive proximity sensors. The data collection system was structured on the basis of an NI 6008 A/D converter of National Instruments. An electronic circuit command was developed through the A/D converter for a remote firing of the test stand. The equipment monitoring is performed through the data collected from the sensors. The vibration signals collected by accelerometers are processed in the time domain and frequency. Also, proximity probes were used for the axis orbit evaluation and an inductive sensor for the rotation and trigger measurement. © (2013) Trans Tech Publications, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to determine the resistance level of Haemonchus contortus isolated from the Santa Inês flock of the Embrapa (Brazilian government's Agricultural Research Company), Southeast Livestock Unit (CPPSE), as well as to determine costs of characterizing and maintaining this isolate in host donors. Forty-two male Santa Inês lambs were experimentally infected with 4000 H. contortus infective larvae of the field isolate of CPPSE, called Embrapa2010, and divided into six treatment groups, which received triclorfon, albendazol plus cobalt sulfate, ivermectin, moxidectin, closantel and levamisole phosphate, as well as a negative control group (water). Egg per gram (EPG) counts were performed at 0, 3, 7, 10 and 14. days post treatment when the animals were slaughtered for parasite count. The data were analyzed using the RESO statistical program, considering anthelmintic resistance under 95% of efficacy. EPG and worm count presented a linear and significant relation with 94% determination coefficient. The susceptibility results obtained by RESO through both criteria (EPG and worm count) were equal, except for closantel, showing that the isolate Embrapa2010 is resistant to benzimidazoles, macrocyclic lactones and imidazothiazoles. The need of a control group did not appear to be essential since the result for susceptibility in the analyses with or without this group was the same. Suppression in egg production after treatment did not occur in the ivermectin and moxidectin groups. In the control group, the establishment percentage was just 12.5 because of the low number of third-stage larvae, resistance (innate and infection immunity) of the animals studied plus good nutrition. Drug classes presented similar efficacy between adults and immature stages. The costs for isolate characterization were calculated for 42 animals during 60. days. The total cost based on local market rates was approximately US$ 8000. The precise identification of Brazilian isolates and their establishment in host donors would be useful for laboratorial anthelmintic resistance diagnoses through in vitro tests, which has an annual cost of approximately US$ 2500 for maintenance in host donors. © 2012 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research aimed to estimate body contents of protein and energy and net requirements of energy for maintenance of buffaloes, slaughtered at different stages of maturity. There were used 14 Mediterranean intact males with initial average body weight of 352.2 +/- 24.3 kg and average age of 24 months. The animais were randomly divided into four experimental groups. One group was designed to slaughter at the beginning of the experimental period (IS). The animals of another group were restricting fed, receiving, individually, levels of protein and energy 15% above maintenance (RF). The animals of the two remaining groups were individually fed ad libitum (SW450 and SW500) to reach weights corresponding to 100 and 110 percent of the mature weight of the buffalo cows (respectively 450 and 550 kg). The ration contained ground-corn cobs, soybean meal, urea, minerals, and signal-grass (Brachiaria decumbens) hay, with a concentrate: roughage ratio of 50: 50 and 13% of crude protein on a dry matter basis. To estimate changes in body composition inside the range of weights included in the trial, linear regression equations of log protein (kg), fat (kg) and energy (Mcal) as a function of log empty-body-weight (EBW), in kg, were fitted. Energy requirements for maintenance were obtained as estimated heat production at zero level of energy intake. Buffaloes submitted to fattening in feedlot presented early body fat deposition, and had with the same live weight lower protein content and higher fat content and energy per unit weight than european-zebu crossbred cattle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the role of the implant/abutment system on torque maintenance of titanium retention screws and the vertical misfit of screw-retained implant-supported crowns before and after mechanical cycling. Materials and Methods: Three groups were studied: morse taper implants with conical abutments (MTC group), external-hexagon implants with conical abutments (EHC group), and external-hexagon implants with UCLA abutments (EHU group). Metallic crowns casted in cobalt-chromium alloy were used (n = 10). Retention screws received insertion torque and, after 3 minutes, initial detorque was measured. Crowns were retightened and submitted to cyclic loading testing under oblique loading (30 degrees) of 130 +/- 10 N at 2 Hz of frequency, totaling 1 x 10(6) cycles. After cycling, final detorque was measured. Vertical misfit was measured using a stereomicroscope. Data were analyzed by analysis of variance, Tukey test, and Pearson correlation test (P < .05). Results: All detorque values were lower than the insertion torque both before and after mechanical cycling. No statistically significant difference was observed among groups before mechanical cycling. After mechanical cycling, a statistically significantly lower loss of detorque was verified in the MTC group in comparison to the EHC group. Significantly lower vertical misfit values were noted after mechanical cycling but there was no difference among groups. There was no significant correlation between detorque values and vertical misfit. Conclusions: All groups presented a significant decrease of torque before and after mechanical cycling. The morse taper connection promoted the highest torque maintenance. Mechanical cycling reduced the vertical misfit of all groups, although no significant correlation between vertical misfit and torque loss was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)