93 resultados para Linear range
Resumo:
A comparative study was accomplished between two immobilization methodologies for the meldola's blue (MB), used to decrease the oxidation potential of NADH. The study was performed with glassy carbon electrode by electropolymerization of pyrrole and MB through the technique of cyclic voltammetry being evaluated the effect of the number of cycles to define the thickness and the stability of the film. With 25 cycles it was obtained the best result. They were also investigated the modification of the graphite electrode with film formed by the system sol-gel PPO 300 or PPO 4000 for the dip-coating, through two methods: occlusion and adsorption. The best method was it of adsorption of MB during 10 min, following by deposit of the film PPO 300, favored for the time of drying (24 hours). The adsorption of MB followed by PPO 300 deposition presented broader linear range than PPy methodology. ©2006 Sociedade Brasileira de Química.
Resumo:
This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química.
Resumo:
A simple analytical method for quantification of atenolol in pharmaceutical formulations by diffuse reflectance spectroscopy is described. The method is based on the reaction, on the filter paper surface, between the drug and p-chloranil producing a colored compound. The best reaction conditions were obtained with 20 μL of atenolol solution and 20 μL of p-chloranil. All reflectance measurements were carried out at 550 nm and the linear range was from 1.13×10-2 to 7.88×10-2 mol L-1 (r = 0.9992). The limit of detection was 2.80 × 10-3 mol L-1. The proposed method was successfully applied to analysis of different commercial brands of pharmaceutical formulations and the results obtained by the proposed method were in good agreement with those obtained using the British Pharmacopoeia method.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes the use of Au nanoparticle (NP)-containing hydrogel microstructures in the development of electrochemical enzyme-based biosensors. To fabricate biosensors, AuNPs were conjugated with glucose oxidase (GOX) or horseradish peroxidase (HRP) molecules and were dispersed in the prepolymer solution of poly(ethylene glycol) diacrylate (PEG-DA). Vinylferrocene (VF) was also added into the prepolymer solution in order to lower operating potential of the biosensor and to prevent oxidation of interfering substances. The prepolymer solution was photolithographically patterned in alignment with an array of Au electrodes fabricated on glass. As a result, electrode arrays became functionalized with AuNP/GOX- or AuNP/HRP-carrying hydrogel microstructures. Performance of the biosensors was characterized by impedance spectroscopy, chronoapmerometry and cyclic voltammetry. Impedance measurements revealed that inclusion of Au nanoparticles improved conductivity of PEG hydrogel by a factor of 5. Importantly, biosensors based on AuNP-GOX complex exhibited high sensitivity to glucose (100μAmM -1cm -2) in the linear range from 0.1 to 10mM. The detection limit was estimated to be 3.7×10- 7M at a signal-to-noise ratio of 3. Biosensors with immobilized AuNP/HPR had a linear response from 0.5 to 5.0μM of hydrogen peroxide with sensitivity of 1.4mAmM -1cm -2. The method for fabricating nanoparticle-carrying hydrogel microstructures described in this paper should be widely applicable in the development of robust and sensitive electrochemical biosensors. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper describes the development and application of a simple, cheap, and clean method for the quantification of furosemide in urine samples from athletes, to detect doping, using a combined spot test/diffuse reflectance spectroscopy procedure. The method is based on the complexation reaction of furosemide (5-(aminosulfonyl)-4-chloro-2-((furanylmethyl)amino)benzoic acid, dissolved in ethanol, with FeCl3 and the surfactant dodecyltrimethylammonium bromide (DTAB) in aqueous solution, yielding a colored compound on the surface of a filter paper. The reagent concentrations were optimized using a chemometric experimental design. The reflectometric measurements of the complex formed were carried out at 477nm. The linear range obtained was 1.65-9.00×10-3molL-1 of furosemide (R=0.997), and the detection and quantification limits were 4.9×10-4 and 1.62×10-3molL-1, respectively. The proposed method was successfully applied in the analysis of furosemide in spiked urine, demonstrating that it is a reliable alternative method for the detection of furosemide doping in sport. © 2012 Elsevier B.V..
Resumo:
Canine distemper virus (CDV) is a viral disease that affects dogs and many other carnivores. Clinical diagnosis of CDV is difficult due to the broad spectrum of signs that may be confounded with other respiratory and enteric diseases of dogs. Laboratory analysis is required to diagnose suspected cases. In this study, surface plasmon resonance (SPR) and electrochemical impedance spectroscopy (EIS) methodologies were developed for the detection of canine distemper virus simultaneously. The assay exhibited high specificity, as all the negative controls were not mistakenly detected. The CDV concentration was determined from successive injections into the apparatus, with a linear range from 1.1 to 116.0 ng mL-1. The system exhibited good reproducibility with 4.5% variation between runs after regeneration of the coated surface with a solution of 0.1 M glycine-HCL (pH 3.0). The capacitance and resistance values of the modified interface were calculated from EIS data using an equivalent circuit. It was possible to measure CDV in highly concentrated viruses with good specificity and reproducibility. © 2013 The Royal Society of Chemistry.
Resumo:
A surface confined redox group contributes to an interfacial charging (quantifiable by redox capacitance) that can be sensitively probed by impedance derived capacitance spectroscopy. In generating mixed molecular films comprising such redox groups, together with specific recognition elements (here antibodies), this charging signal is able to sensitively transduce the recognition and binding of specific analytes. This novel transduction method, exemplified here with C-reactive protein, an important biomarker of cardiac status and general trauma, is equally applicable to any suitably prepared interfacial combination of redox reporter and receptor. The assays are label free, ultrasensitive, highly specific and accompanied by a good linear range. © 2013 Elsevier B.V.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Farmacêuticas - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Desenvolvimento de métodos limpos para screening e determinação de sulfonamidas em matrizes diversas
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)