129 resultados para Fourier analysis in several variables


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of the platform-switching technique on stress distribution in implant, abutment, and pen-implant tissues, through a 3-dimensional finite element study. Three 3-dimensional mandibular models were fabricated using the Solid Works 2006 and InVesalius software. Each model was composed of a bone block with one implant 10 mm long and of different diameters (3.75 and 5.00 mm). The UCLA abutments also ranged in diameter from 5.00 mm to 4.1 mm. After obtaining the geometries, the models were transferred to the software FEMAP 10.0 for pre- and postprocessing of finite elements to generate the mesh, loading, and boundary conditions. A total load of 200 N was applied in axial (0 degrees), oblique (45 degrees), and lateral (90) directions. The models were solved by the software NeiNastran 9.0 and transferred to the software FEMAP 10.0 to obtain the results that were visualized through von Mises and maximum principal stress maps. Model A (implants with 3.75 mm/abutment with 4.1 mm) exhibited the highest area of stress concentration with all loadings (axial, oblique, and lateral) for the implant and the abutment. All models presented the stress areas at the abutment level and at the implant/abutment interface. Models B (implant with 5.0 mm/abutment with 5.0 mm) and C (implant with 5.0 mm/abutment with 4.1 mm) presented minor areas of stress concentration and similar distribution pattern. For the cortical bone, low stress concentration was observed in the pen-implant region for models B and C in comparison to model A. The trabecular bone exhibited low stress that was well distributed in models B and C. Model A presented the highest stress concentration. Model B exhibited better stress distribution. There was no significant difference between the large-diameter implants (models B and C).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the search for the ideal bone substitute has been the focus of a large number of studies, autogenous bone is still the gold standard for the filling of defects caused by pathologies and traumas, and mainly, for alveolar ridge reconstruction, allowing the titanium implants installation. Objectives: The aim of this study was to evaluate the dynamics of autogenous bone graft incorporation process to surgically created defects in rat calvaria, using epifluorescence microscopy. Material and methods: Five adult male rats weighing 200-300 g were used. The animals received two 5-mm-diameter bone defects bilaterally in each parietal bone with a trephine bur under general anesthesia. Two groups of defects were formed: a control group (n=5), in which the defects were filled with blood clot, and a graft group (n=5), in which the defects were filled with autogenous bone block, removed from the contralateral defect. The fluorochromes calcein and alizarin were applied at the 7th and 30th postoperative days, respectively. The animals were killed at 35 days. Results: The mineralization process was more intense in the graft group (32.09%) and occurred mainly between 7 and 30 days, the period labeled by calcein (24.66%). Conclusions: The fluorochromes showed to be appropriate to label mineralization areas. The interfacial areas between fluorochrome labels are important sources of information about the bone regeneration dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study aimed to evaluate the influence of implants with or without threads representation on the outcome of a two-dimensional finite element (FE) analysis. Materials and Methods: Two-dimensional FE models that reproduced a frontal section of edentulous mandibular posterior bone were constructed using a standard crown/implant/screw system representation. To evaluate the effect of implant threads, two models were created: a model in which the implant threads were accurately simulated (precise model) and a model in which implants with a smooth surface (press-fit implant) were used (simplified model). An evaluation was performed on ANSYS software, in which a load of 133 N was applied at a 30-degree angulation and 2 mm off-axis from the long axis of the implant on the models, The Von Mises stresses were measured. Results: The precise model (1.45 MPa) showed higher maximum stress values than the simplified model (1.2 MPa). Whereas in the cortical bone, the stress values differed by about 36% (292.95 MPa for the precise model and 401.14 MPa for the simplified model), in trabecular bone (19.35 MPa and 20.35 MPa, respectively), the stress distribution and stress values were similar. Stress concentrations occurred around the implant neck and the implant apex. Conclusions: Considering implant and cortical bone analysis, remarkable differences in stress values were found between the models. Although the models showed different absolute stress values, the stress distribution was similar. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:1040-1044

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Bone graft procedures have been used commonly in buco-maxillo-facial surgery. For this reason, many researchers have evaluated the bone substitutes.Purpose:The present study evaluated soft and hard tissue reactions to two different hydroxyapatites HAs (synthetic HA and natural HA) and bioactive glass implanted into the sockets immediately after extraction.Materials and Methods:First and third upper and lower premolars, on both sides, were extracted from six female dogs. The alveolar sockets were randomly assigned to four groups: Group 1 - control (unfilled), Group 2 - filled with synthetic hydroxyapatite, Group 3 - filled with bovine bone mineral (natural HA), and Group 4 - filled with bioactive glass. The animals were euthanized at 4 weeks (n = 2), 8 weeks (n = 2), and 28 weeks (n = 2) after extraction. The mandible and maxilla of each animal were removed for histological analysis to determine soft tissue reactions, newly formed bone, bone characteristics, and presence or absence of implanted materials.Results:Most particles of synthetic hydroxyapatite had bone formation on their surface, although some particles showed a layer of fibrous connective tissue. The bovine bone mineral group exhibited particles partially replaced with bone formation. The bioactive glass group showed particles with a thin layer of calcified tissue, but was absent in some specimens, suggesting complete resorption.Conclusion:All biomaterials had similar behavior. Bovine bone mineral, compared to synthetic hydroxyapatite and bioactive glass, showed a larger number of particles covered with osseous tissue. All biomaterials interfered with the socket repair process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram analisados os cromossomos de 117 bovinos de diferentes raças para identificação de fusão cêntrica e os cromossomos de 100 éguas jovens da raça Brasileiro de Hipismo para identificação de linhagens 63,X, utilizando a técnica de identificação do X baseada na heterocromatina intersticial do braço longo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silver nitrate staining of rainbow trouts (Oncorhynchus mykiss) chromosomes, for the identification of the nucleolar organizing regions (NORs), revealed that in individuals from Nucleo Experimental de Salmonicultura de Campos do Jordao (Brazil) NORs were located in the long arms of a submetacentric pair while in specimens from Mount Shasta (USA) NORs were located in the short arms of a submetacentric pair. Cytogenetic analysis of the offspring, obtained through artificial crosses including individuals from both stocks, allowed the identification of NORs in two submetacentric chromosomes, one in the short arms and the other in the long arms, confirming the effectiveness of the hybridization process. Complementary results obtained using the FISH technique with 18S and 5S rDNA probes showed that NOR-bearing chromosomes exhibited a cluster of 5S genes located in tandem with the 18S gene cluster in both stocks. The results allow us to suggest that the difference in NOR-bearing chromosomes found between the two stocks is likely to be due to a pericentric inversion involving the chromosome segment where 18S and 5S rDNA genes are located. The presence of ribosomal genes in the long arms of a submetacentric chromosome is apparently a particular characteristic of the rainbow trout stock of Campos do Jordao and might be used as a chromosome marker in studies of controlled crosses in this species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morphological differences among 6 species of marine fishes belonging to 2 subfamilies of the family Serranidae (Serraninae: Dules auriga, Diplectrum formosum, and D, radiale; Epinephelinae: Epinephelus marginatus, Mycteroperca acutirostris, and M. bonaci) were studied by the geometric morphometric method of thin-plate splines and multivariate analysis of partial-warp scores. The decomposition of shape variation into uniform and nonaffine components of shape change indicate that major differences among species are related to both components of shape variation. Significant differences were found among species with respect to the uniform components, but there is no clear separation of taxonomic groups related to these components, and species are instead separated on the basis of body height and caudal peduncle length. Non-uniform changes in body shape, in turn, clearly differentiate the species of Serraninae and Epinephelinae. These shape changes are probably related to differences in habitat and feeding habits among the species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXTO: Alterações do gene supressor de tumor p53, como mutações e deleções, são lesões genéticas encontradas com maior freqüência nas neoplasias humanas, incluindo câncer de mama, pulmão e cólon. Entre as malignidades hematológicas, o gene 53 é freqüentemente mutado no linfoma de Burkitt, sendo detectadas mutações em 30-40% das amostras tumorais e em 70% das linhagens celulares. OBJETIVO: Analisar as alterações do gene p53 em crianças com linfoma não-Hodgkin de origem B. TIPO DE ESTUDO: Estudo descritivo. LOCAL: Centro de Oncologia Terciário. PARTICIPANTES: O estudo analisou 12 pacientes com linfoma não-Hodgkin B classificados como linfoma de Burkitt. A análise de possíveis mutações do gene p53 foi realizada pela técnica de PCR-SSCP dos exons 5, 6 ,7 e 8/9 do gene. RESULTADOS: Um padrão anormal de migração foi observado em quatro pacientes (33.3%), em um paciente no exon 6 e em três no exon 7. Os casos positivos incluíam dois pacientes que evoluíram para o óbito por progressão da doença. CONCLUSÃO: Esses resultados preliminares sugerem que as alterações do gene p53 são freqüentes em crianças com linfoma de Burkitt e podem contribuir para patogênese ou progressão da doença.