101 resultados para FLOW-INJECTION AMPEROMETRY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A calibration method was developed using flow injection analysis (FI) with a Gradient Calibration Method (GCM). The method allows the rapid determination of zinc In foods (approximately 30 min) after treatment with concentrated sulphuric acid and 30% hydrogen peroxide, and analysis with flame atomic absorption spectrometry (FAAS). The method provides analytical results with a relative standard deviation of about 2% and requires less time than by conventional FI calibration. The electronic selection of different segments along the gradient and monitoring of the technique covers wide concentration ranges while maintaining the inherent high precision of flow injection analysis. Concentrations, flow rates, and flow times of the reagents were optimized in order to obtain best accuracy and precision. Flow rates of 10 mL/min were selected for zinc. In addition, the system enables electronic dilution and calibration where a multipoint curve can be constructed using a single sample injection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study investigates the chemical composition of the African plant Parkia biglobosa (Fabaceae) roots and barks by Liquid Chromatography - Electrospray Ionization and Direct Injection Tandem Mass Spectrometry analysis. Mass spectral data indicated that B-type oligomers are present, namely procyanidins and prodelphinidins, with their gallate and glucuronide derivatives, some of them in different isomeric forms. The analysis evidenced the presence of up to 40 proanthocyanidins, some of which are reported for the first time. In this study, the antiradical activity of extracts of roots and barks from Parkia biglobosa was evaluated using DPPH method and they showed satisfactory activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, an electrode chemically modified with polypyrrole (PCME) was employed for determination of sulfate in ethanol fuel using a FIA system. The PCME was prepared by polymerization of pyrrole at a glassy carbon electrode by means of cyclic voltammetry technique. An analytical curve from 1.0 x 10−5 to 8.0 x 10−5 mol L−1 was obtained in flow injection system based on the PCME. An amperometric sensibility of 2.3 x 10−3 A mol−1 L and a detection limit of 2.5 x 10−6 mol L−1 were achieved. The proposed method was employed for determination of sulfate ions in commercial samples of ethanol fuel. The results were in good agreement with those obtained by the ionic chromatographic method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a new methodology for the construction of very efficient flow cells for mercury detection by potentiometric stripping analysis, employing the thin gold layer of recordable CDs as working electrode is reported. This new source of electrodes (CDtrodes) show very attractive performance, similar to that obtained with commercial gold electrodes, with superior versatility. The low cost of this new source of gold electrodes allows a frequent replacement of the electrode, avoiding cumbersome clean-up treatments. Various experimental parameters have been optimized to yield low detection limits (0.25 ng/mL of mercury for 5 min deposition at 0.3 V) and good precision (standard deviation of 1.9% was obtained for 15 repetitive measurements using 10 ng/mL of mercury). Standard curves were found to be linear over the range of 0.5-100 μg L-1 of mercury. The flow cells developed were used for the quantification of mercury in oceanic and tap water. © Springer-Verlag 2000.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, the polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, the performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper deals with the development and optimization of an analytical procedure using ultrafiltration and a flow-injection system, and its application in in-situ experiments to characterize the lability and availability of metal species in humic-rich hydrocolloids. The on-line system consists of a tangential flow ultrafiltration device equipped with a 3-kDa filtration membrane. The concentration of free ions in the filtrate was determined by atomic-absorption spectrometry, assuming that metals not complexed by aquatic humic substances (AHS) were separated from the complexed species (M-AHS) retained by the membrane. For optimization, exchange experiments using Cu(II) solutions and AHS solutions doped with the metal ions Ni(II), Mn(II), Fe(III), Cd (II), and Zn(II) were carried out to characterize the stability of the metal-AHS complexes. The new procedure was then applied in-situ at a tributary of the Ribeira do Iguape river (Iguape, São Paulo State, Brazil) and evaluated using the ions Fe(III) and Mn(II), which are considered to be essential constituents of aquatic systems. From the exchange between metal-natural organic matter (M-NOM) and the Cu(II) ions it was concluded that Cu(II) concentrations > 485 mu g L(-1) were necessary to obtain maximum exchange of the complexes Mn-NOM and Fe-NOM, corresponding to 100% Mn and 8% Fe. Moreover, the new analytical procedure is simple and opens up new perspectives for understanding the complexation, transport, stability, and lability of metal species in humic-rich aquatic environments.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Droplets formed at the tip of a tube under the same conditions possess extreme uniformity of form, volume and weight. These properties of liquid drop formation have been known for a long time and consequently many applications for the drop have been found in instrumentation and chemical analysis methods. In the present paper, we report on the analytical use of a dynamic LED-based flow-through optical absorption detector with optical path length controlled by continuous dropping of a solution. This arrangement consists of a flow cell built within a high-intensity red LED (lambda (max)=630 nm). The feasibility of the detector is demonstrated by colorimetric determination of methylene blue, and ammonium by Berthelot's reaction, in a flow-injection system. For ammonium, the reaction forms a blue dye (indophenol) with a maximum absorption at 630-650 nm. The detection limit, considered as 3 times the signal of the blank, is better than 125 mu g l(-1). The small flow cell represents a good combination of optical path length, low volume and fast washout. This detector can be used advantageously in automated methods and can represent a solution to problems of optical detection involving gas bubbles and precipitation of particles in turbidimetric applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simple and attractive method for quantification of ascorbic acid (AA) in beers, soda, natural juices and commercial vitamin C tablets was achieved by combining Bow injection analysis and amperometric detection. An array of gold microelectrodes electrochemically modified by deposition of palladium was employed as working electrode which was almost unaffected by fouling effects. Ascorbic acid was quantified in beverages and vitamin tablets using amperometric differential measurements. This method is based on three steps involving the flow injection of: 1) the sample plus a standard addition of AA, 2) the pure sample, and 3) the enzymatically-treated sample. The enzymatic treatment was carried out with Cucumis sativus tissue, which is a rich source of ascorbate oxidase, at pH 7. The calibration plots for freshly prepared ascorbic acid standards were very linear in the concentration range of 0.18-1.8 mg L-1 with a relative standard deviation (RSD) < 1%, while for real samples the deviations were between 2.7% to 8.9%.