61 resultados para Embedment strength


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study Design. Case-control study.Objective. To evaluate respiratory muscle force in children with myelomeningocele. Summary of Background Data. Myelomeningocele is a common spinal cord malformation with limitations linked to central nervous system lesions and abnormalities in respiratory movements. Despite this, little attention has been given to evaluating respiratory muscle force in these patients.Methods. Children with myelomeningocele aged between 4 and 14 years ( myelomeningocele group; MG, n = 20) were studied and compared with healthy children ( control group; CG, n = 20) matched for age and gender. Respiratory muscular force was evaluated by maximum inspiratory ( Pimax) and expiratory ( Pemax) pressures.Results. Groups were similar for age [ CG = 8 ( 6 - 13) = MG = 8 ( 4 - 14), P > 0.05]; gender, and body mass index [ CG = 17.4 ( 14.1 - 24.7) x MG = 19.2 ( 12.6 - 31.9), P > 0.05]. The lumbosacral region was predominantly affected ( 45%). Maximum respiratory pressures were significantly higher in CG than MG ( Pimax = CG: similar to 83 +/- 21.75 > MG: -54.1 +/- 23.66; P < 0.001 and Pemax = CG: + 87.4 +/- 26.28 > MG: + 64.6 +/- 26.97; P = 0.01). Patients with upper spinal lesion ( UL) had lower maximum respiratory pressure values than those with lower spinal lesion ( LL), [Pimax ( UL = - 38.33 +/- 11.20 cm H2O x LL = - 60.85 +/- 24.62 cm H2O), P < 0.041 and Pemax ( UL = + 48 +/- 20.82 cm H2O x LL + 71.71 +/- 26.73 cm H2O), P = 0.067]).Conclusion. Children with myelomeningocele at the ages studied presented reduced respiratory muscle force with more compromise in upper spinal lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of intravaginal electrical stimulation (IES) on pelvic floor muscle (PFM) strength in patients with mixed urinary incontinence (MUI). Between January 2001 and February 2002, 40 MUI women (mean age: 48 years) were studied. Urge incontinence was the predominant symptom; 92.5% also presented mild stress urinary incontinence (SUI). Selection criteria were clinical history and urodynamics. Pre-treatment urodynamic study showed no statistical differences between the groups. Ten percent of the women in each group had involuntary detrusor contractions. Patients were randomly distributed, in a double-blind study, into two groups. Group G 1 (n=20), effective IES, and group G2 (n=20), sham IES, with follow-up at 1 month. The following parameters were studied: (1) clinical questionnaire, (2) examiner's evaluation of perineal muscle strength, (3) objective evaluation of perineal muscle by perineometry, (4) vaginal weight test, and (5) urodynamic study. The IES protocol consisted of three 20-min sessions per week over a 7-week period using a Dualpex Uro 996 at 4 Hz. There was no statistically significant difference in the demographic data of both groups. The number of micturitions per 24 h after treatment was reduced significantly in both groups. Urge incontinence, present in all patients before treatment, was reduced to 15% in G1 and 31.5% in G2 post-treatment. The subjective evaluation of PFM strength demonstrated a significant improvement in G1. Objective evaluation of PFM force by perineometer showed a significant improvement in maximum peak contraction post-treatment in both groups. In the vaginal weight test, there was a significant increase in average number of cone retentions post-treatment in both groups. With regard to satisfaction level, after treatment, 80% of the patients in G1 and 65% of the patients in G2 were satisfied. There was no statistically significant difference between the groups. There was a significant improvement in PFM strength from both effective and sham electrostimulation, questioning the effectiveness of electrostimulation as a monotherapy in treating MUI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To assess pelvic floor muscle (PFM) strength in women with stress urinary incontinence (SUI) and urge urinary incontinence (UUI).Materials and Methods: 51 women were prospectively divided into two groups, according to the symptoms as SUI (G1 = 22) or UUI (G2 = 29). Demographic data, such as number of pads/ 24 hours, number of micturations/ 24 hours and nocturia, delay time of urgent void (i.e., the time period for which an urgent void could be voluntarily postponed), number of parity and vaginal deliveries were obtained using a clinical questionnaire. Objective urine loss was evaluated by 60-min. Pad Test, subjective urine stream interruption test (UST) and visual survey of perineal contraction. Objective evaluations of PFM were performed in all patients (vaginal manometry).Results: Median of age, mean number of pads/ 24 hours, nocturia and warning time were significantly higher in UUI comparing to SUI group. During UST, 45.45% in G1 and 3.44%, in G2, were able to interrupt the urine stream (p < 0.001). The 60-min. Pad Test was significantly higher in G2 compared to G1 women (2.7 +/- 2.4 vs 1.5 +/- 1.9 respectively, p = 0.049). Objective evaluation of PFM strength was significantly higher in the SUI than in the UUI patients. No statistical difference was observed regarding other studied parameters.Conclusion: Pelvic floor muscle weakness was significantly higher in women with UUI when compared to SUI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to compare the pelvic floor muscle strength of nulliparous and primiparous women.METHODS: A total of 100 women were prospectively distributed into two groups: Group 1 (G1) (n = 50) included healthy nulliparous women, and Group 2 (G2) (n = 50) included healthy primiparous women. Pelvic floor muscle strength was subjectively evaluated using transvaginal digital palpation. Pelvic floor muscle strength was objectively assessed using a portable perineometer. All of the parameters were evaluated simultaneously in G1 and were evaluated in G2 during the 20(th) and 36(th) weeks of pregnancy and 45 days after delivery.RESULTS: In G2, 14 women were excluded because they left the study before the follow-up evaluation. The median age was 23 years in G1 and 22 years in G2; there was no significant difference between the groups. The average body mass index was 21.7 kg/m(2) in G1 and 25.0 kg/m(2) in G2; there was a significant difference between the groups (p = 0.0004). In G2, transvaginal digital palpation evaluation showed significant impairments of pelvic floor muscle strength at the 36(th) week of pregnancy (p = 0.0006) and 45 days after vaginal delivery (p = 0.0001) compared to G1. Objective evaluations of pelvic floor muscle strength in G2 revealed a significant decrease 45 days after vaginal delivery compared to nulliparous patients.CONCLUSION: Pregnancy and vaginal delivery may cause weakness of the pelvic floor muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Classico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 see, and manufacturing microwave cycle - 320W/3 min + OW/3 min + 720W/3 min); T(Classico, water bath cycle - 74 degrees C/9h) and Q (Jet, press chamber cycle - 50 degrees C/15 min at 2 bar). Ten specimens (65 x 10 x 3.3 mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 +/- 5.31; B = 107.57 +/- 3.99; C = 109.63 +/- 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 +/- 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The effect of methyl methacrylate (MMA) monomer on the bond strength of three types of denture base resins (Acron MC, Lucitone 550 and QC-20) to two types of acrylic teeth (Biotone and Trilux) was evaluated. Twenty specimens were produced for each denture base resin/acrylic tooth combination and were randomly divided into control (acrylic teeth received no surface treatment) and experimental groups (MMA was applied to the surface of the acrylic teeth for 180 s) and were submitted to shear tests (1 mm/mm). Data (MPa) were analyzed using three-way ANOVA/Student's test (alpha = 0.05). MMA increased the bond strength of Lucitone denture base resins and decreased the bond strength of QC-20. No difference was detected for the bond strength of Acron MC base resin after treatment with MMA. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to investigate the influence of shortening the etching time on the bond strength of a conventional and a self-etching primer adhesive system used in primary tooth dentin.Methods. Flat dentin surfaces were obtained from 24 primary molars, randomly assigned to 4 experimental groups. The adhesive systems Single Bond and Clearfil SE Bond were applied in two groups according to the manufacturers' recommendations. In the other two groups, the adhesives were applied after half-time of acid etching, 7 s for Single Bond and 10 s for Clearfil SE Primer. Resin crowns were built up and after 24 h storage in water at 37 &DEG; C, the teeth were sectioned to produce beams with cross-sectional area of approximately 0.49 mm(2). Specimens were tested in tension at 0.5 mm/min until failure. Fractured specimens were analyzed to determine the failure mode.Results. Tensile bond strengths for Single Bond in primary dentin were higher than for Clearfil SE Bond. Shortening of acid etching time improved bond strength only for Single Bond, while no statistically significant difference was observed for Clearfil SE Bond when both etching times were compared.Significance. No detrimental effect on bond strength was observed when the time of acid etching was shortened in 50%. Shortening the time for a procedure in a small child without compromising the quality of the work is a very important finding for the practicing pediatric dentist. © 2004 Elsevier Ltd. All rights reserved.