47 resultados para Eatwell plate
The effect of locked screw angulation on the biomechanical properties of the S.P.S. Free-Block plate
Resumo:
Objectives: Among the locked internal fixators is one denominated S.P.S. (Synthesis Pengo System) Free-Block, which was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw angulation on the resistance of the S.P.S. Free--Block plate. Methods: Forty synthetic bone cylinders with 10 mm fracture gap were used. Forty seven-hole 3.5 mm stainless steel plates (two AO-like dynamic compression holes and five locked holes) were assembled according to the orientation of the locked screws: mono cortical screws were positioned at 90° to the long axis of the cylinder (Group 1), and monocortical screws were positioned at 70° to its cylinder long axis (Group 2). In both groups, AO-like dynamic compression hole screws were positioned bicortically and neutrally. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure --seven by bending and seven in compression. Results: No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. Clinical significance: In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block to tests of axial compression and four-point bending. © Schattauer 2013.
Resumo:
Quantitative variations in heterotrophic plate count (HPC) and in the presence of indicator microorganisms in 0.5, 1.5 and 20-L bottles of different brands of Brazilian mineral water were analyzed during their shelf life. No variations were identified in the presence of indicator microorganisms, but quantitative variations in HPC were observed in some brands, which suggests that changes may be occurring in the water quality during storage. The aim of this study was also to evaluate the quality of the bottled mineral waters and the presence of enterococci and Pseudomonas aeruginosa were verified in six and two bottles, respectively, which is in disagreement with the microbiological quality criteria established in the current legislation. Although no limit is set for HPC in mineral water, this study relies on the limit of 500 colony-forming units per mL of sample (CFU/mL). Seventy-two bottles presented levels above 500 CFU/mL and up to 560,000 CFU/mL. This study showed that the control of HPC (<500 CFU/mL) for non-returnable packaging seems to be adequate to ensure the quality of mineral water during storage. The high values of HPC and its variations detected during storage seem to fully justify the need for a reevaluation of the use of HPC in bottled mineral water quality management. More detailed studies on the potential health risk of HPC and its variations in mineral water are also needed. © 2012 Elsevier Ltd.
Resumo:
Several Lamb wave modes can be coupled to a particular structure, depending on its geometry and transducer used to generate the guided waves. Each Lamb mode interacts in a particular form with different types of defects, like notches, delamination, surface defects, resulting in different information which can be used to improve damage detection and characterization. An image compounding technique that uses the information obtained from different propagation modes of Lamb waves for non-destructive testing of plate-like structures is proposed. A linear array consisting of 16 piezoelectric elements is attached to a 1 mm thickness aluminum plate, coupling the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two images are obtained from amplitude and phase information: one image using the Total Focusing Method (TFM) and one phase image obtained from the Sign Coherence Factor (SCF). Each TFM image is multiplied by the SCF image of the respective mode to improve contrast and reduce side and grating lobes effects. The high dispersive characteristic of the A0 mode is compensated for adequate defect detection. The information in the SCF images is used to select one of the TFM mode images, at each pixel, to obtain the compounded image. As a result, dead zone is reduced, resolution and contrast are improved, enhancing damage detection when compared to the use of only one mode. © 2013 Elsevier Ltd.
Resumo:
A multiyear solution of the SIRGAS-CON network was used to estimate the strain rates of the earth surface from the changing directions of the velocity vectors of 140 geodetic points located in the South American plate. The strain rate was determined by the finite element method using Delaunay triangulation points that formed sub-networks; each sub-network was considered a solid and homogeneous body. The results showed that strain rates vary along the South American plate and are more significant on the western portion of the plate, as expected, since this region is close to the subduction zone of the Nazca plate beneath the South American plate. After using Euler vectors to infer Nazca plate movement and to orient the velocity vectors of the South American plate, it was possible to estimate the convergence and accommodation rates of the Nazca and South American plates, respectively. Strain rate estimates permitted determination of predominant contraction and/or extension regions and to establish that contraction regions coincide with locations with most of the high magnitude seismic events. Some areas with extension and contraction strains were found to the east within the stable South American plate, which may result from different stresses associated with different geological characteristics. These results suggest that major movements detected on the surface near the Nazca plate occur in regions with more heterogeneous geological structures and multiple rupture events. Most seismic events in the South American plate are concentrated in areas with predominant contraction strain rates oriented northeast-southwest; significant amounts of elastic strain can be accumulated on geological structures away from the plate boundary faults; and, behavior of contractions and extensions is similar to what has been found in seismological studies. © 2013 Elsevier Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Several countries have been passed by change processes in their fundamental geodesic structure with the focus on the adoption of geocentric reference systems. In Brazil, the adoption of the SIRGAS2000 evolves the coexistence of two realizations from the COrrego Alegre system, two realizations from the SAD69 system and one realization from the SIRGAS2000 system. To make use of products in the old reference systems, methods of coordinate transformation between the existent reference frames are necessary. So, in this paper one solution for the transformation between coordinates from different reference frames, based on Thin-Plate Splines (TPS), that allows the estimation of parameters from one linear transformation and also one non-linear model is presented. The TPS model was developed to work with tridimensional coordinates and in this paper the results and analysis are performed with simulated data and also with data from the official Brazilian Geodetic System (SGB). In the check points from SAD69 stations (realization of 1996 - SAD69/96), the values of RMSE obtained were of 78,2 mm in latitude and 67,5 mm in longitude, before the transformation to the SIRGAS2000. In the comparison between the TPS model and ProGriD (Brazilian software provided by IBGE), the statistical indicators were reduced in 97%, by using the TPS model. Based in the obtained results from real dataset, the TPS model appears to be promising, since it allows improving the quality of transformation process with simultaneous distortion modeling.
Resumo:
Objective: To compare the hard tissue changes at implants installed applying edentulous ridge expansion (E.R.E.) at sites with a buccal bony wall thickness of 1 or 2 mm.Material and methods: In six Labrador dogs, the first and second maxillary incisors were extracted, and the buccal alveolar bony plates and septa were removed. After 3 months of healing, partial-thickness flaps were dissected, and the E.R.E. was applied bilaterally. Hence, an expansion of the buccal bony crest was obtained in both sides of the maxilla with a displacement of either a 1- or a 2-mm-wide buccal bony plate at the test and control sites, respectively. After 3 months of healing, biopsies were obtained for histological analyses.Results: A buccal vertical resorption of the alveolar crest of 2.3 +/- 0.8 and 2.1 +/- 1.1 mm, and a coronal level of osseointegration at the buccal aspect of 2.7 +/- 0.5 and 2.9 +/- 0.9 mm were found at the test (1 mm) and control (2 mm) sites, respectively. The differences did not reach statistical significance. The mean values of the mineralized bone-to-implant contact (MBIC%) ranged from 62% to 73% at the buccal and lingual sites. No statistically significant differences were found. Horizontal volume gains of 1.8 and 1.1 mm were observed at the test and control sites, respectively, and the difference being statistically significant.Conclusions: Implants installed using the E.R.E. technique yielded a high degree of osseointegration. It is suggested that the displacement of buccal bony plates of 1 mm thickness is preferable compared with that of wider dimensions.
Resumo:
Vortex shedding phenomenon produced by a square cylinder placed close to a smooth flat plate is experimentally studied by means of flow visualization techniques and hot-film anemometry. Qualitative and quantitative information about the flow field has been obtained for Reynolds numbers up to 1,000. Vortex shedding images in several Reynolds number have been captured and the non dimensional vortex shedding frequency has been obtained as a function of the Reynolds number.
Resumo:
Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors
Resumo:
Purpose: The objective of this article is to describe a method to construct an intraoralacrylic device that permits a reline material to be added to the inner surface of thepalatal plate.Materials and Methods: Fifteen 60-day-old adult female rats (Rattus NorvegicusAlbinus Wistar), weighing 150 to 250 g were used for this study and allocated to threegroups (n = 5): G1, animals wearing a heat-polymerized acrylic resin palatal plate(Lucitone 550) for 14 days; G2, animals wearing a heat-polymerized acrylic resinpalatal plate (Lucitone 550) relined with Tokuyama Rebase II for 14 days; and G3,animals maintained under the same conditions as the experimental groups, withoutwearing palatal plates for 14 days. The manipulation of the animals followed theguidelines of the Brazilian College of Animal Experimentation, under the approval ofthe animal ethics committee of the State University of Ponta Grossa. The palatal platescovered the whole palate, were fixed in the molar region with light-cured resin, andwere kept there for 14 days. The animals received a paste diet and water ad libitum.Before and after the trial period, the rats were weighed individually on a precisionscale. Statistical analysis was performed using a two-way analysis of variance (α =0.05) test for comparison of the animals’ weight (g) at time 0 and after 14 days ofusing the palatal plate.Results: No statistical differences were observed regarding the weight of the animalsamong the experimental groups in the study.Conclusions: The individual master impressions, the molar teeth coverage, and themethod of cementation with nonadhesive composite resin provided good stability forthe palatal plate showed in this study, not disturbing the eating habits and nutritionof the animals. This model seems reproducible, offering adequate histopathologicalevaluation. Differences in tissue morphology exist between the animals that used thepalatal plate and the animals that did not use this device. Use of these palatal platescould clarify how prostheses bring changes in the palatal mucosa of users.
Resumo:
Although measurement errors can impair statistical analysis, reliability analysis has been neglected in applied microbiology. This study assessed the intra-rater reproducibility of the Agar-based method for estimation of phospholipase activity (Pz). Pz readings were performed twice by two examiners (E1, E2), either directly on plates or in photos, and both black and white backgrounds were used. Pz values were taken from one or triplicate colonies from each sample (n=30). Intra-examiner reproducibility was estimated using Intraclass Correlation Coefficient (ICC). For both examiners, reading triplicate (ICCE1=0.91, ICCE2=0.86) was better than one colony (ICCE1=0.86, ICCE2=0.80). E1 had an excellent concordance when measurements were performed on photos using a white background (ICC=0.95) and a good concordance in the other conditions
Resumo:
ObjectiveThe aim of this clinical report was to reestablish the buccal bone wall after immediate implant placement. The socket defect was corrected with autogenous bone, and a connective tissue graft was removed from the maxillary tuberosity to increase the thickness, height, and width of the buccal bone and gingival tissue followed by immediate provisionalization of the crown during the same operation.Clinical ConsiderationsA 66-year-old patient presented with a hopeless maxillary left central incisor with loss of the buccal bone wall. Atraumatic, flapless extraction was performed, and an immediate implant was placed in the extraction socket followed by preparation of an immediate provisional restoration. Subsequently, immediate reconstruction of the buccal bone plate was performed, using the tuberosity as the donor site, to obtain block bone and connective tissue grafts, as well as particulate bone. Finally, immediate provisionalization of the crown followed by simple sutures was performed. Cone-beam computed tomography and periapical radiographs were taken before and after surgery. After 4 months, the final prosthetic crown was made. After a 2-year follow-up, a satisfactory aesthetic result was achieved with lower treatment time and morbidity.ConclusionThis case demonstrates the effective use of immediate reconstruction of the buccal bone wall for the treatment of a hopeless tooth in the maxillary aesthetic area. This procedure efficiently promoted harmonious gingival and bone architecture, recovered lost anatomical structures with sufficient width and thickness, and maintained the stability of the alveolar bone crest in a single procedure.Clinical SignificanceIf appropriate clinical conditions exist, immediate dentoalveolar restoration may be the most conservative means of reconstructing the buccal bone wall after immediate implant placement followed by immediate provisionalization with predictable healing and lower treatment time.