512 resultados para Controle de qualidade em radiodiagnósticos


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper considers a study of the anatomical features of the cardiac system and a three-dimensional model of the different tunics that comprise the heart wall, for processing and quality control of radiological images. The structures are built by the layer overlapping method, where a layer can be understood as a slice of the three-dimensional object. The pericardium, myocardium and endocardium were represented with three-dimensional cylinders and hexagons. The spatial arrangement of the cardiac system is determined by an background image of a real model, which values are defined according to the shape of the region and on the anatomical patients characteristics. The results are significant, considering the anatomical structures details, as well as the representation of the thicknesses of the regions of the heart wall. The validation of the anatomical model was accomplished through comparisons with dimensions obtained from a real model and allows verifying that the model is appropriate. The degree of representation will allow the verification of the influence of radiological parameters, morphometric peculiarities and stage of the diseases on the quality of the images, as well as on the performance of the Computer-Aided Diagnosis (CAD).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ANVISA (National Health Surveillance Agency) has published in recent years, laws that regulate the stages of the control of plants derivatives, including tests of macro and microscopic botanical identification, phytochemical determination, tests of authenticity and purity, microbiological testing, among other parameters. All the analytical procedures of plant drugs control required by law must be based on the Brazilian Pharmacopoeia, other Pharmacopoeias recognized by ANVISA or quality control guides of plant species published by the World Health Organization (WHO). This study aimed to evaluate some pharmacognostic, phytochemical screening and microbiological control of plant species of the Brazilian cerrado, which have indicated ethnopharmacological: Byrsonima intermedia (Bi), Bauhinia holophylla (Bh) and Myrcia bella (Mb). In addition, certain parameters were determined for obtaining extracts from plants sprayed and dried. These data are important to obtain new scientific information from Brazilian plants with therapeutic potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vitamin C is vulnerable to oxidative degradation and then the aim of this study was conducting a literature review about quality control of vitamin C in finished products. The conclusion is determined multiple emulsions and products which contain encapsulant materials are able to protect it from oxidation ensuring its efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A introdução do assunto qualidade, segundo as necessidades de mercado abre espaço para a discussão da qualidade como necessidade pessoal, e também para a formação do cidadão/profissional, além de introduzir assuntos específicos de administração de empresas. Dessa forma, foi oferecida uma disciplina optativa para os alunos do Instituto de Química do Campus de Araraquara, abordando o tema Qualidade e foi denominada Gestão da Qualidade por três anos seguidos. da avaliação geral do curso extraiu-se que ele deveria ser realizado sempre, que o tema é atual e relevante e contribui para a formação profissional/pessoal. Com relação ao comprometimento com o curso de graduação, cerca de metade dos alunos assume o seu comprometimento com os estudos e os restantes dizem estarem somente envolvidos. Conclui-se, portanto que o curso atingiu os seus objetivos propostos, introduziu os principais conceitos de qualidade segundo as normas da qualidade da série ISO 9000 e suscitou a discussão da formação do aluno/profissional/cidadão.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUÇÃO: A utilização correta de um plasma-controle para a comparação com o plasma do paciente nos testes de coagulação é fundamental para a garantia de um resultado seguro dessas provas laboratoriais. OBJETIVO: O presente estudo analisou a viabilidade do uso de um pool de plasma caseiro, realizado com cinco (P5) e 20 (P20) amostras a partir de pacientes normais, para ser utilizado como controle normal do tempo de tromboplastina parcial (TTP). MATERIAL E MÉTODO: Os dois pools de plasma caseiro foram analisados em relação a um controle normal comercial (AP). Foram 10 dias de experimento e a cada dia os dois pools caseiro eram feitos. Para cada dia foi feito o TTP de P5, P20 e AP. Todos os pacientes com solicitação de TTP, em cada dia do experimento, tiveram a relação de tempos (R) determinada frente a P5, P20 e AP. As ferramentas estatísticas utilizadas foram média (X), análise de variância e teste de Tukey. RESULTADOS: A análise estatística demonstrou que os valores de TTP são significativamente diferentes entre AP e P5 e entre AP e P20, mas não há diferença significativa entre P5 e P20. Quando a relação de tempos foi analisada, não houve diferença significativa entre AP, P5 e P20. CONCLUSÃO: O estudo demonstrou que pode ser utilizado como controle normal um pool de plasma caseiro, feito a partir de cinco ou 20 amostras.