46 resultados para Coenzyme Q(10)


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The interplay between temperature and q-deformation in the phase transition properties of many-body systems is studied in the particular framework of the collective q-deformed fermionic Lipkin model. It is shown that in phase transitions occuring in many-fermion systems described by su(2)q-like models are strongly influenced by the q-deformation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we employ the construction of the Dirac bracket for the remaining current of sl(2) q deformed Kac-Moody algebra when constraints similar to those connecting the sl(2)-Wess-Zumino-Witten model and the Liouville theory are imposed to show that it satisfies the q-Virasoro algebra proposed by Frenkel and Reshetikhin The crucial assumption considered in our calculation is the existence of a classical Poisson bracket algebra induced in a consistent manner by the correspondence principle, mapping the quantum generators into commuting objects of classical nature preserving their algebra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses a design approach for a high-Q low-sensitivity OTA-C biquad bandpass section. An optimal relationship is established between transconductances defining the differenceβ - γ in the Q-factor denominator, setting the Q-sensitivity to tuning voltages around unity. A 30-MHz filter was designed based on a 0.35μn CMOS process and VDD=3.3V. A range of circuit simulation supports the theoretical analysis. Q-factor spans from 20.5 to 60, while ensuring filter stability along the tuning range. Although a Mode-operating OTA is used, the procedure can be extended to other types of transconductor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This case-control study analyzed mass spectrometry fingerprinting patterns of culture media samples used for embryo culture to predict embryo implantation. Methods: The culture medium harvested after embryo transfer of 22 embryos from 13 patients was used for the experiments. After embryo transfer, the remaining culture media were collected and samples were split in positive (n=8) and negative (n=14) implantation groups according to implantation outcomes (100% or 0% of implantation). Samples were individually diluted and injected directly to the Electrospray ionization (ESI) MS coupled to a Quadrupole Time-of-flight MS (Q-ToF-MS).Ions relative intensities of each spectrum were considered. Data analysis was conducted in MatLab 7.0 version using Partial Least Squares - Discriminant Analysis toolbox. Results: There were 3027 observed ions at 100% and 0% implantation groups by ESI-Q-ToF-MS. The statistical model could categorize the samples in two clusters, based on their positive and negative implantation outcomes. Less intense ions present in the mass spectra with statistical significance have contributed to the major differences to group distinction. Conclusions: Positive and negative implantation embryos showed a specific biochemical pattern present in culture media, which could be detected as a fast, simple and non-invasive way. This biochemical profile could help the selection of the most viable embryo, improving single embryo transfer and thus eliminating the risk and undesirable outcomes of multiple pregnancies. © Todos os direitos reservados a SBRA - Sociedade Brasileira de Reprodução Assistida.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The two fundamental approaches to fission-track dating involve either an explicit determination of the thermal neutron fluence (φ-method) or a calibration against age standards (ζ-method). The neutron fluence measurements are carried out with metal-activation monitors or with uranium-fission monitors, co-irradiated with the samples. Uranium-fission monitors consist of either a thin mono-atomic) film, or a thick fission source (standard uranium glass) irradiated against a muscovite external track detector. In this work, different techniques for performing neutron-fluence measurements were compared: based on thin-film calibration, based on thick-source calibration, and based on gamma spectrometry of co-irradiated metal monitors (Au, Co). The results suggest that more experiments are needed to make all calibrations consistent, including new measurements of the length of etched induced tracks in mica. Also the standard glass calibration carried out with thin films should be confirmed with a greater number of calibrating irradiations. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper summarizes the parallel session C6 Q&A-everything you wanted to know about gravitational waves but were afraid to ask of the joint 10th Amaldi Conference on Gravitational Waves and 20th International Conference on General Relativity and Gravitation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Let B[X; S] be a monoid ring with any fixed finite unitary commutative ring B and is the monoid S such that b = a + 1, where a is any positive integer. In this paper we constructed cyclic codes, BCH codes, alternant codes, Goppa codes, Srivastava codes through monoid ring . For a = 1, almost all the results contained in [16] stands as a very particular case of this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present a method for evaluating the center density of algebraic lattices from subfields of Q(xi n), where n is a positive integer. This method allows to reproduce rotated versions of dense lattices in some dimensions. Constellations on algebraic lattices with high packing density have been proposed for use in communications in Gaussian channels and also in Rayleigh fading channels in case they have high diversity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The elevated Q-angle seems to be one of the most suggested factors contributing to patellofemoral pain. Females with patellofemoral pain are often evaluated through static clinical tests in clinical practice. However, the adaptations seem to appear more frequently in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Therefore, the aim of this study was to determine the reliability and discriminatory capability of three Q-angle measurements: a static clinical test, peak dynamic knee valgus during stair ascent and a static measurement using a three-dimensional system. Twenty-nine females with patellofemoral pain and twenty-five pain-free females underwent clinical Q-angle measurement and static and dynamic knee valgus measurements during stair ascent, using a three-dimensional system. All measurements were obtained and comparisons between groups, reliability and discriminatory capability were calculated. Peak dynamic knee valgus was found to be greater in the patellofemoral pain group. On the other hand, no significant effects were found for static knee valgus or clinical Q-angle measurements between groups. The dynamic variable demonstrated the best discriminatory capability. Low values of reliability were found for clinical Q-angle, in contrast to the high values found for the three-dimensional system measurements. Based on our findings, avoiding or correcting dynamic knee valgus during stair ascent may be an important component of rehabilitation programs in females with patellofemoral pain who demonstrate excessive dynamic knee valgus. Q-angle static measurements were not different between groups and presented poor values of discriminatory capability.