51 resultados para Clock Synchronization
Conception rates at ET in lactating dairy recipient cows after estrous or ovulation synchronization.
Resumo:
This paper presents an improved and updated taxonomy for Time Warp based distributed synchronization protocols. This taxonomy aims to allow the grouping of several optmistic distributed simulation synchronization protocols, with the objective to facilitate the task to decide which protocol is better for a specific simulation.
Resumo:
The objectives of the present study were to evaluate factors associated with estrous synchronization responses and pregnancy per insemination (P/AI) in Bos indicus beef cows submitted to progesterone-based fixed-time artificial insemination (FTAI) protocols. A total of 2388 cows (1869 Nellore and 519 crossbred Nellore x Angus) from 10 commercial farms were evaluated to determine the relationships among breed, body condition score (BCS) on the first day of the FTAI protocol, the occurrence of estrus between progesterone device removal and FTAI and diameter of largest ovarian follicle (LF) at FTAI on estrous synchronization responses and P/AI. Cows (n=412 primiparous; 1976 multiparous) received an intravaginal device containing progesterone or an ear implant containing norgestomet (a progestin), and an injection of estradiol at the beginning of the estrous synchronization protocol. Body condition was scored using a 1-5 scale on the first day of the FTAI protocol and at 30-60 days postpartum. Females received 300IU of equine chorionic gonadotropin (eCG) and PGF(2 alpha) on the day the progesterone device/implant was removed and were inseminated 48-60h later. At insemination, cows (n=2388) were submitted to an ultrasonographic exam to determine the diameter of the LF. Follicles were classified into four categories based on mean and standard deviation (SD) of the LF (LF1 = two SD below the mean; LF2 = mean minus one SD; LF3 = mean plus one SD; LF4 = two SD above the mean). Ovulation rate was determined in a subset of cows (n=813) by three consecutive ultrasonographic exams: (1) at time of progesterone device/implant removal, (2) at time of FTAI and (3) 48 h after FTAI. Ovulation was defined as the disappearance of a large follicle (>= 8.0 mm) that was previously recorded. Estrus was determined in a subset of the cows (n = 445) by the activation of a detection of estrous patch placed on the tail head on the day of progesterone device/implant removal. Pregnancy was diagnosed 30 days after FTAI. Pregnancy was influenced (P = 0.001) by follicle diameter [LF1 = 27.5% (81/295), LF2 = 46.6% (328/705), LF3 = 57.9% (647/1118), LF4 = 63.3% (171/270)] and the occurrence of estrus [estrus = 67.7% (174/257) and no estrus = 36.2% (68/188)]. Follicle diameter at FTAI influenced ovulation rate [LF1 = 42.5% (34/80), LF2 = 73.9% (161/218), LF3 = 95.8% (407/425), LF4 = 97.8% (88/90)], the occurrence of estrus [LF1 = 54.8% (51/93), LF2 = 33.6% (43/128), LF3 = 68.9% (126/183), LF4 = 90.2% (37/41)] and P/AI among cows that had ovulations [LF1 =32.4% (11/34), LF2 = 50.3% (81/161), LF3 = 60.0% (244/407), LF4 = 68.2% (60/88)]. Improving estrous responses between progesterone device withdrawal and FTAI and increasing the diameter of the LF at FTAI may be important aspects to achieve improved estrous synchronization responses and P/AI following progesterone/progestin and estradiol based FTAI protocols in suckled Bos indicus cows. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper discusses the main characteristics and presents a comparative analysis of three synchronization algorithms based respectively, on a Phase-Locked Loop, a Kalman Filter and a Discrete Fourier Transform. It will be described the single and three-phase models of the first two methods and the single-phase model of the third one. Details on how to modify the filtering properties or dynamic response of each algorithm will be discussed in terms of their design parameters. In order to compare the different algorithms, these parameters will be set for maximum filter capability. Then, the dynamic response, during input amplitude and frequency deviations will be observed, as well as during the initialization procedure. So, advantages and disadvantages of all considered algorithms will be discussed. ©2007 IEEE.
Resumo:
The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
A robust exponential function based controller is designed to synchronize effectively a given class of Chua's chaotic systems. The stability of the drive-response systems framework is proved through the Lyapunov stability theory. Computer simulations are given to illustrate and verify the method. © 2013 Patrick Louodop et al.
Resumo:
The aim of this work was to study estrus synchronization and fixed time artificial insemination (FTAI) in dairy buffaloes during season anestrus. One hundred thirty-nine dairy buffaloes in seasonal anestrus were divided in two groups as G1(n=66) and G2(n=73). The protocols for both the groups were the same until day (D)14:D0 administration of 2.0 mg estradiol benzoate and implantation of progesterone device (P4) for 14 days; D14 removal of P4 plus 150 mg of cloprostenol and 400 IU of equine chorionic gonadotropin. On D16, G1 received 10 mg of buserelin and G2 100 mg deslorelin acetate. On D17, both the groups were submitted to FTAI. Ultrasonographic examinations of ovaries were performed on D0, D14, D16 and D17. Results showed that pregnancy rates in G1 and G2 were 20 and 41% (p<0.05) and the ovulation rates were 16.6 and 37%, respectively (p<0.05). The dominant follicle (DF) diameter on D16 was 7.9 mm in G1 and 8.9 mm in G2 (p>0.05). Thirty-five percent of the animals in G1 and 54.1% in G2 showed a diameter DF greater than 8.0 mm on D16 (p>0.05). Thus, it could be concluded that the protocols synchronized the estrus, leading the concentration of the parturitions in the period of low milk production. Deslorelin was more efficient than buserelin due the higher percentage of DF ovulation and higher pregnancy rates.
Resumo:
O objetivo deste estudo foi avaliar a eficiência do uso de duas doses de PGF associadas ou não à administração de hCG no início do estro sobre os parâmetros reprodutivos de cabras leiteiras. Um total de 29 cabras receberam duas doses de 30 µg d-cloprostenol pela via latero-vulvar com 10 dias de intervalo (Dia 1 e Dia 10). As cabras foram alocadas para receberem o hCG (250 IU) ou salina i.m. no momento em que o estro foi detectado. Depois da realização da segunda dose de PGF, o estro foi monitorado e exames ultrassonográficos foram realizados duas vezes ao dia. Todas as fêmeas foram inseminadas 16 h após o inicio do estro. Amostras de sangue foram coletadas diariamente para determinação das concentrações plasmáticas de progesterona. O uso do hCG no momento do início do estro não afetou os parâmetros estudados e, portanto, os dados serão apresentados agrupados. A taxa de manifestação de estro foi similar (P > 0,05) na primeira (75,9% - 22/29) ou na segunda dose de PGF (79,3% - 23/29). O intervalo entre a administração de PGF e o início do estro foi maior (P < 0,05) no Dia 1 (75,8±53,9 h) que no Dia 10 (47,7±10,1 h). Duração do estro também diferiu (P < 0,05) 35,4±15,9 (Dia 1) vs 26,8±15, 0 h (Dia 10). A taxa de ovulação foi 79,3% (23/29) após a segunda dose PGF. Não foi encontrada diferença (P>0,05) entre os grupos experimentais quanto aos parâmetros reprodutivos: intervalo entre a aplicação da segunda dose e a ovulação (86,6±11,4h), intervalo do estro a ocorrência da ovulação (39,9±12,3h), diâmetro do maior folículo (7,2±1,4) e número de ovulações (1,8±0,6). No Dia 1, 52,4% (11/21) apresentavam concentrações de progesterona < 1 ng/mL. No Dia 10, 100% dos animais apresentavam concentrações >1ng/mL. O presente estudo permite concluir que o estro pode ser eficientemente sincronizado em cabras leiteiras com duas doses de PGF intervaladas em 10 dias. Novas pesquisas devem se realizadas para avaliar diferentes doses e momentos de utilização do hCG.
Resumo:
This paper addresses the problem of finite-time synchronization of tunnel diode based chaotic oscillators. After a brief investigation of its chaotic dynamics, we propose an active adaptive feedback coupling which accomplishes the synchronization of tunnel-diode-based chaotic systems with and without the presence of delay(s), basing ourselves on Lyapunov and on Krasovskii-Lyapunov stability theories. This feedback coupling could be applied to many other chaotic systems. A finite horizon can be arbitrarily established by ensuring that chaos synchronization is achieved at a pre-established time. An advantage of the proposed feedback coupling is that it is simple and easy to implement. Both mathematical investigations and numerical simulations followed by PSPICE experiment are presented to show the feasibility of the proposed method.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of the present study was to evaluate the effects of type of norgestomet auricular implant (new - N or previously used during 5 days - U), season of the year (summer - S and winter - W), and parity (12 heifers - H and 23 cows - C) on synchronization of follicular wave emergence in buffaloes. For this purpose, 35 buffaloes were examined daily by ultrasonography until follicular wave emergence was detected. Data were analysed by ANOVA, using PROC GLIMMIX. No interactions were observed in none variables. Time of follicular wave emergence and number of follicles at emergence were not affected by type of implant or season of the year. Parity also did not influence the number of follicles at emergence. However, follicular wave emergence occurred later in heifers than in cows. In conclusion, the previous use of a norgestomet auricular implant independent of the season of the year does not affect the time or the number of follicles at follicular wave emergence in buffaloes. Nevertheless, although heifers and cows had a similar number of follicles at emergence, the time of follicular wave emergence occurs earlier in cows than in heifers.