38 resultados para CRITICAL LAYER THICKNESS
Resumo:
This work analyzed the loss of sensible heat from one fluid to be considered homogeneous heat distribution on a thermal reservoir with cylindrical geometries composite insulating layers. We studied two thermal reservoirs with a volume of 20 liters, and the first has a layer thickness of 75 mm of expanding polyurethane foam wrapped in the polycarbonate container and the second container has only layer thickness of 5 mm of polycarbonate, as insulation of fluid of the external environment. The experimental results are compared with theoretical results obtained through a calculation script, displayed and detailed during the work development, from the theory of energy balance. The maximum error introduced between the theoretical and experimental results were 3.5% and 1.4% respectively for the Boilers with or without a polyurethane coating
Resumo:
Equipamento e processo de enriquecimento superficial seletivo de ligas metálicas. É descrito um equipamento e processo de enriquecimento superficial seletivo de ligas metálicas com controle da velocidade e da intensidade do processo, de forma a permitir controlar a espessura da camada enriquecida e a diminuição do tempo necessário para ser obtida camada enriquecida com espessura desejada.
Resumo:
Histomorphometric data were obtained from cats uterine horns: either nulliparous (n = 6), primiparous (n = 6), multiparous (n = 6) and treated with contraceptive (n = 6). The material was collected after surgery, fixed in paraformaldehyde and embedded in paraplast® resin to be sliced in a microtome. The obtained sections were stained with hematoxylin - eosin and measured under a light microscope: uterine wall total thickness (μm), endometrium total height, endometrial glands diameter and glandular epithelia height, total myometrium, internal and external myometrium and vascular layer thickness. It was concluded that: 1 - contraceptive use and number of pregnancies altered the uterine structure, 2 - one pregnancy does not appear to affect the uterine lining structures as occurs in multiparous cats, 3 – there was no variation on the evaluated structures between nulliparous and primiparous cats except for inner myometrium, 4 - the total myometrium hight and the endometrium hight showed similar variations except for the contraceptive treated cats group, 5 - the outer myometrium showed marked changes in the treated cats, 6 – the less marked morphological variations were for the endometrial glands diameter and glandular epithelium hight, 7 - the presence of dilated endometrial glands was found only in treated cats.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
We report on the use of dynamic scale theory and fractal analyses in the Study of distinct growth stages of layer-by-layer (LBL) films of poly(allylamine hydrochloride) (PAH) and a side-chain-substituted azobenzene copolymer (Ma-co-DR13). The LBL films were adsorbed oil glass substrates and characterized with atomic force microscopy with the Ma-co-DR13 at the top layer. The ganular morphology exhibited by the films allowed the observation of the growth process inside and outside the grains. The growth outside the grains was found to follow the Kardar-Parisi-Zhang model, with fractal dimensions of ca. 2.6. One could expect that inside the grains the morphology would be close to a Euclidian surface with fractal dimension of ca. 2 for any growth stage. The latter, however, was observed only for thicker films containing more than 10 bilayers. For thinner films the morphology was well described by a self-affine fractal. Such dependence of the growth behavior with the film thickness is associated with a more complete coverage of adsorption sites in thicker films due to diffusion of polymer molecules. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
An experimental model and a mathematical model with the introduction of a ramp in the channel of Obenaus model are presented. The aim is to present a better reproduction of the real layer pollution deposited on the HV insulators. This better reproduction is obtained from two types of thickness variation: the introduction of a ramp (soft variation) and the introduction of a step (sudden variation). The computational simulations and the experimental data suggest that the introduction of the ramp is the better reproduction of the layer pollution. The ramp approximates to the real layer pollution more than the step.
Resumo:
Adhesive restorations have increasingly been used in dentistry, and the adhesive system application technique may determine the success of the restorative procedure. The aim of this study was to evaluate the influence of the application technique of two adhesive systems (Clearfil SE Bond and Adper Scotchbond MultiPurpose) on the bond strength and adhesive layer of composite resin restorations. Eight human third molars were selected and prepared with Class I occlusal cavities. The teeth were restored with composite using various application techniques for both adhesives, according to the following groups (n = 10): group 1 (control), systems were applied and adhesive was immediately light activated for 20 seconds without removing excesses; group 2, excess adhesive was removed with a gentle jet of air for 5 seconds; group 3, excess was removed with a dry microbrush-type device; and group 4, a gentle jet of air was applied after the microbrush and then light activation was performed. After this, the teeth were submitted to microtensile testing. For the two systems tested, no statistical differences were observed between groups 1 and 2. Groups 3 and 4 presented higher bond strength values compared with the other studied groups, allowing the conclusion that excess adhesive removal with a dry micro-brush could improve bond strength in composite restorations. Predominance of adhesive fracture and thicker adhesive layer were observed via scanning electron microscopy (SEM) in groups 1 and 2. For groups 3 and 4, a mixed failure pattern and thinner adhesive layer were verified. Clinicians should be aware that excess adhesive may negatively affect bond strength, whereas a thin, uniform adhesive layer appears to be favorable. (Quintessence Int 2013;44:9-15)
Resumo:
Results of the analysis of dynamic behavior of flashover phenomenon on the high voltage-polluted insulators are presented. These results were taken from a mathematical and an experimental model that introduce the variable thickness influence of the layer pollution deposited on the high-voltage insulator surface. Analysis of the flashover was done by way of introducing a variation in the thickness of the channel of Obenaus' model, simulating a layer pollution of variable thickness. The objective was to obtain a better reproduction of the real layer pollution deposited on the insulator that works in the polluted regions. Two types of thickness variations were used: a sudden variation, using a step; and a soft variation, using a ramp; that were put along the way of the discharge. Comparison between the mathematical and experimental models showed that introduction of a ramp makes Obenaus' model more efficient in analyzing behavior of flashover phenomenon.