48 resultados para Balneario de Soportilla (Burgos)
Resumo:
The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Commissioning studies of the CMS hadron calorimeter have identified sporadic uncharacteristic noise and a small number of malfunctioning calorimeter channels. Algorithms have been developed to identify and address these problems in the data. The methods have been tested on cosmic ray muon data, calorimeter noise data, and single beam data collected with CMS in 2008. The noise rejection algorithms can be applied to LHC collision data at the trigger level or in the offline analysis. The application of the algorithms at the trigger level is shown to remove 90% of noise events with fake missing transverse energy above 100 GeV, which is sufficient for the CMS physics trigger operation. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Studies of the performance of the CMS drift tube barrel muon system are described, with results based on data collected during the CMS Cosmic Run at Four Tesla. For most of these data, the solenoidal magnet was operated with a central field of 3.8 T. The analysis of data from 246 out of a total of 250 chambers indicates a very good muon reconstruction capability, with a coordinate resolution for a single hit of about 260 μm, and a nearly 100% efficiency for the drift tube cells. The resolution of the track direction measured in the bending plane is about 1.8 mrad, and the efficiency to reconstruct a segment in a single chamber is higher than 99%. The CMS simulation of cosmic rays reproduces well the performance of the barrel muon detector. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
In October and November 2008, the CMS collaboration conducted a programme of cosmic ray data taking, which has recorded about 270 million events. The Resistive Plate Chamber system, which is part of the CMS muon detection system, was successfully operated in the full barrel. More than 98% of the channels were operational during the exercise with typical detection efficiency of 90%. In this paper, the performance of the detector during these dedicated runs is reported. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS detector is designed around a large 4 T superconducting solenoid, enclosed in a 12 000-tonne steel return yoke. A detailed map of the magnetic field is required for the accurate simulation and reconstruction of physics events in the CMS detector, not only in the inner tracking region inside the solenoid but also in the large and complex structure of the steel yoke, which is instrumented with muon chambers. Using a large sample of cosmic muon events collected by CMS in 2008, the field in the steel of the barrel yoke has been determined with a precision of 3 to 8% depending on the location. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
Latin-American Society of Forensic Genetics (SLAGF) Interlaboratory Quality Control Exercise (2010-2011) included the analysis of three bloodstain samples in FTA Classic Card (three persons, biologically unrelated) and one theoretical exercise. There were 56 participating laboratories from 13 Latin-American countries that belong to society, were reported 70 STRs, including autosomal and sex chromosome markers with consensus in 53 STRs with a rate in reporting errors of 2.3%. Fifty-six laboratories reported results in theoretical exercise with mistakes in calculation of IP for each marker. It is necessary to hold meetings to discuss the results of this exercise to reach conclusions and recommendations on all aspects of DNA forensics analysis and paternity test, to improve results and quality in the results of each laboratory. © 2011 Elsevier B.V.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O volume, organizado pelo professor Danilo Rothberg, reúne artigos de docentes e pesquisadores de pós-graduação das áreas de ciências humanas e sociais que buscam esclarecer ações que envolvem a comunicação desenvolvida por atores sociais a fim de ampliar os espaços democráticos. A maior parte dos artigos são de autoria de docentes da Unesp e tratam de temas relacionados à comunicação via Internet e de sua aplicação em iniciativas políticas e de interação de instâncias de poder com o público. Mas o livro ainda discute outros meios, como rádio e televisão, além da comunicação organizacional. A obra procura aplicar o conhecimento científico no campo da comunicação desenvolvido nas universidades à realidade do Brasil de hoje. Diante do quadro de constante inovação das formas de se comunicar observado nos últimos anos, os autores contribuem para superar um cenário de aparente falta de informações sobre as realizações políticas e de gestão do setor.
Resumo:
Background: Rheumatic diseases in children are associated with significant morbidity and poor health-related quality of life (HRQOL). There is no health-related quality of life (HRQOL) scale available specifically for children with less common rheumatic diseases. These diseases share several features with systemic lupus erythematosus (SLE) such as their chronic episodic nature, multi-systemic involvement, and the need for immunosuppressive medications. HRQOL scale developed for pediatric SLE will likely be applicable to children with systemic inflammatory diseases.Findings: We adapted Simple Measure of Impact of Lupus Erythematosus in Youngsters (SMILEY (c)) to Simple Measure of Impact of Illness in Youngsters (SMILY (c)-Illness) and had it reviewed by pediatric rheumatologists for its appropriateness and cultural suitability. We tested SMILY (c)-Illness in patients with inflammatory rheumatic diseases and then translated it into 28 languages. Nineteen children (79% female, n= 15) and 17 parents participated. The mean age was 12 +/- 4 years, with median disease duration of 21 months (1-172 months). We translated SMILY (c)-Illness into the following 28 languages: Danish, Dutch, French (France), English (UK), German (Germany), German (Austria), German (Switzerland), Hebrew, Italian, Portuguese (Brazil), Slovene, Spanish (USA and Puerto Rico), Spanish (Spain), Spanish (Argentina), Spanish (Mexico), Spanish (Venezuela), Turkish, Afrikaans, Arabic (Saudi Arabia), Arabic (Egypt), Czech, Greek, Hindi, Hungarian, Japanese, Romanian, Serbian and Xhosa.Conclusion: SMILY (c)-Illness is a brief, easy to administer and score HRQOL scale for children with systemic rheumatic diseases. It is suitable for use across different age groups and literacy levels. SMILY (c)-Illness with its available translations may be used as useful adjuncts to clinical practice and research.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)