478 resultados para Estabilidade da fase Ti3Si
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Pós-graduação em Matematica Aplicada e Computacional - FCT
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Ciências Biológicas (Genética) - IBB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The stroke, cause of morbidity and mortality, has been associated with imbalance in the neural control of the heart, which contributes to the decrease in heart rate variability (HRV) and a prognostic factor for cardiacevents and arrhythmias. The aim of this study was to in investigate the autonomic modulation of heart rate of men suffering from lesions stroke in chronicphase. Eight menaged 58.62 ± 2.88 years, 27.41 ± 5.33 kg/m2of bodymass índex, with paresis for at least six months were studied. Heart rate (HR) and RR intervals (iR-R) were recorded at rest in supine position for 10 minutes. Geometric índices of the Poincaré plot were calculated: SD1, associatedwith vagal activity; SD2, associated with global activity but sympathetic predominance, and the relationship of both (SD1/SD2). Geometric index values in the sample: SD1 = 20,54 ± 9,90ms; SD2 = 36,80 ± 30,61ms; SD1/SD2 = 0,49 ± 0,04. The reference values from literature for healthy subjects are: SD1 = 19.6 ± 9.4ms e 22.8 ± 16.1 ms; SD2 = 43.2 ± 17.7 ms e 56.3 ± 12.3 ms; SD1/SD2 = 0.49 ± 0.21ms. Men in chronic phase of stroke haven't autonomic dysfunction analyzed by nonlinear method – Poincaré geometricíndices.
Resumo:
The mini-implant has become a device for anchorage quite widespread and current employee in Orthodontics. The effectiveness of mini-implant is mostly due for its stability primary, however is important to understand about factors that influence the stability. This article presents a review of literature in the database, and as a criterion for inclusion in articles published on the factors related to the stability of mini-implant carried out on humans and animals. The articles was selected according selection criteria related to stability, The factors of mini-implants stability have been described in the literature with scattered scientific information, most of them just as clinical observations. However, these factors of stability can be classified in relation to screw, professional and patient.
Resumo:
Pós-graduação em Engenharia de Produção - FEB