418 resultados para Tomografia Computadorizada de Feixe Cônico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several hormonal and physiological changes that occur during pregnancy directly affect gastrointestinal motility (GI), however, very little is known about the relationship between the electrical and mechanical activities of the stomach and its implications. The aim of this study was to compare the female sex hormones, with profiles of gastrointestinal motility using AC biosusceptometry (BAC) in pregnant rats. Seven female Wistar rats (weighing 250-350 g) were used and all procedures were approved by the local Ethics Committee of animal. Laparotomy was performed on anesthetized rats and a magnetic marker (3.5 mm in diameter and 3.0 mm height) was implanted in the distal stomach. After 10 days of recuperation, the mice were put to mate until confirmation of pregnancy. Fed animals were anesthetized (mg pentobarbital 30 / kg) and kept supine for recording the signal with a sensor 30 min BAC placed on the abdominal surface on days 0, 7, 14 and 20 of gestation. Statistical analysis was performed by Student's t test statistical Newman-Keuls and a P value of .05 was considered statistically significant. The frequency of contraction of the stomach was 74 mHz ± 3, 67 ± 7 mHz, 59 mHz ± 6 (p <0.05 vs day -1) and 71 ± 5 mHz on days -0, -7, -14, and -20, respectively. The values of 44 ± 15 pg / mL and 31 ± 9 pg / ml 25 ± 6 pg / ml, 22 ± 9 pg / ml on days -0, -7, -14 and -20, respectively, obtained by 17ß- estradiol were not statistically significant. The values of progesterone were 13 ± 6 pg / ml at 54 ± 15 pg / ml, 127 ± 42 pg / ml (p <0.05 vs day-1), 22 ± 13 pg / mL on day -0, - 7, -14 and -20, respectively. A linear correlation (Pearson's test) between the lower frequency gastric and increased levels of progesterone was 80% (p <0.0000001). Until then, the relationship between changes in motility and hormone were not described in detail, but with the work that we were able to demonstrate the high correlation between progesterone concentration ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin films of Ga1-xMnxN have great interest in its potential for control of electron spin (spintronics), in most cases this material is synthesized by techniques that have a high degree of control the deposition parameters, such as molecular beam epitaxy (MBE) and deposition of metalorganic chemical vapor deposition (MOCVD). The sputtering technique is an alternative route to produce such materials. Here we study the film deposition Ga1-xMnxN by reactive sputtering technique and apply enhancements such as a glove box, a residual gas analyzer and temperature control system, in order to growth films epitaxially using an analysis of the preconditions of films analyzed by spectroscopic techniques and microscopic. These procedures helped to improve the technique of deposition by cleaning substrates in an inert environment, and by the analysis of trace gases and heating the substrate holder as explained in the literature. Through the applications and comparisons it can be pointed out that the technique has the advantage of its simplicity and relatively low cost compared to MBE and MOCVD, but produces polycrystalline material

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a study about the operation of the major system’s components of a linear particle acclerator (Linac). It addresses the components mainly responsible for the formation of the beam, through the inclusion of several block diagrams showing the details of the structure. Among the systems discussed may be mentioned the system modulator, automatic frequency control, dosimetry and auxiliary systems. The main objective is the dissemination of basic technology applied in linear accelerators and create literature about this subject in national language. Despite the high complexity and large number of devices that comprise a linear accelerator, it has been developed an easy to understand text that adresses the most relevant issues to the operation of the linear accelerator from the point of view of electrical engineering

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this project step is the evolution of scenery matter on the occidental theater media, related to space and technical possibilities of the theatrical building and space on history of contemporary arts. The main point is that scenery must communicate with a specific matter. Something in touch with the plot speeches. Something that makes all the plot elements to communicate. Acting has an specific message to deliver, and that message is what really matter to the viewer of the show. “It’s never late to state that scenery is not a decoration, or just an interior composition. Scenery is not a painting or a sculpture: it’s an integrated art form. It’s never too repetitive to say that scenery is a result from the composition with lights, shadows, shapes, lines and volumes, in balance and on harmony as a whole, that create movement and contrast” (Dias, 2001) On the second step of the project, the objective is to analyze the building process and the scenery aspects of the “Be-a-bá Brasil” show, using illustrations, pictures and analysis data of the context the show was inserted on

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiotherapy is a branch of medical physics related to the treatment of malignant neoplasm, being an important instrument in the fight against cancer, when combined with the effort of a multidisciplinary team, composed of, physicians, physicists, nurses and technicians. Every year more than 3.5 million new cases of cancer are recorded in the world, being the prostate cancer responsible for approximately 25% of this amount (INCA and IARC, 2008). In this type of cancer, radiotherapy is a method indicated for treatement. The technological advance in this area over years has allowed a greater accuracy in the tumor location, more conformation of the radiation beam around the tumor, reducing the dose in healthy tissues and a consequent dose increase on treatment (Bedford et al., 1999). A radiotherapy planning, in which the physicist develops an important role, is composed of several steps, including choosing the best configuration of treatment beams. This choice has a close relationship with success of therapy and is critical to achieve the best distribution of dose inside the tumor and expose the least as possible the healthy tissue to radiation. In this work, two options for setting up camps in the first phase in a treatment of prostate cancer were simulated in computer planning: 4 fields orthogonal or “Box” with gantry angles in 00, 1800, 2700 e 90° and 4 fields angled or “X” (1350, 450, 3150 e 2250). The percentage of the rectal volume exposed to 40, 50, 60, 72 and 76 Gy should be limited to 60, 50, 25, 15 and 5% respectively (Greco et al., 2003). The femoral toxicity have limited dose by 70% of the total dose prescribed in a prostate treatment (Bedford et al., 1999). The planning of 27 patients with prostate adenocarcinoma submitted to 3D conformal radiotherapy were accompanied. As a result, it was assessed that the best TCP (tumor control probability)... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O trabalho propõe rotinas computacionais usando o Método de Monte Carlo com o Código MCNP-5, para analisar os perfis de dose de radiação liberada nos tratamentos de tumores de pele e otimizar os cálculos radiométricos dos feixes de radiação estudados. Foram realizadas medidas dosimétricas do feixe de radiação, comparando os resultados obtidos com os respectivos valores fornecidos pelo serviço de física médica das instituições, com resultados informados pelo fabricante do equipamento e com as simulações computacionais efetuadas com o Código MCNP-5. A quantificação dos erros relativos percentual entre os resultados simulados e os fornecidos pelo Serviço de Radioterapia (E1), os informados pelo fabricante (E2) e os medidos experimentalmente (E3) são inferiores a 4,0% e validam a metodologia computacional proposta para avaliação do comportamento do feixe de raios-X superficial e do feixe de raios γ da unidade de Cobaltoterapia. A metodologia de análise do espectro energético e da curva de porcentagem de dose profunda (PDP) desenvolvida neste trabalho pode ser estendida para estudos de outros feixes clínicos e subsidiar os dados radiométricos utilizados nos planejamentos e cálculos de dose realizados pelo profissional da física médica na sua rotina nos Serviços de Radioterapia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In radiation theraphy with electron beam, the electrons are produced in linear accelerators, and energy the most used have between 4MeV and 20MeV. Generally, the treatments are done for superficial injuries, because the low penetration of these particles. In this work a system for calculation of monitor units (U.M.) for cases of treatments with electron beam was developed. The Excel program of Microsoft was used and is easily found in the operational system of the personal microcomputers. In the Excel has been inserted the pertinent data of the linear accelerator of Varian, model 2100C, used in the Service of radiation theraphy of the Hospital of the Clinics of the College of Medicine of the UNESP of Botucatu. For some values of the physical parameters, such as: factors field and factors calibration, not supplied in the tests of acceptance of the machine, still proceeded calculations from interpolation and extrapolation. The mathematical formulas for automatic search of these and others factors used in the calculations of the determination of the U.M had been developed in agreement available routines in Excel. For this the functions had been used the function IF (that it imposes search condition) and the PROCH (that looks a value in a column from determined line), beyond the basic functions of addition, multiplication and division. It is intended to optimize the routine of the Services of radiation theraphy that perform through eletrontheraphy procedures, speeding the calculations and minimizing the occurrence of errors and uncertainties deriving of the maken a mistake manipulation of the parameters gotten in tables of data of electron beams

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Zona de Falha de Cássia constitui um feixe de falhas de direção preferencial NW-SE e aproximadamente 2 km de largura. Dados de campo, petrográficos e microestruturais evidenciam uma longa história deformacional da zona de falha. Assim, foram caracterizadas três fases de atividade/movimentação da Zona de Falha de Cássia. A primeira fase (précambriana) é caracterizada por deformação em regime dúctil, acarretando na geração de milonitos formados em condições metamórficas de fácies xisto verde. Este é o estágio de formação da falha, apresentando caráter transcorrente oblíqua, com movimentação sinistral inversa. A segunda fase corresponde a uma reativação da zona de falha como uma falha normal, com bloco alto a NE e bloco baixo a SW da referida estrutura. Seu registro é dado pela ocorrência localizada de brechas e cataclasitos. Este episódio de deformação eminentemente rúptil é correlacionado com o Soerguimento do Alto Paranaíba, o que indica movimentação da falha no Neocretáceo. A terceira e última fase é marcada pela formação de depósitos sedimentares plio-pleistocênicos compostos por brecha sedimentar de leques aluviais e sedimentos argilosos lacustres. Tais depósitos são interpretados como originados pelo represamento da drenagem subatual e conseqüente mudança do nível de base local, em decorrência de uma reativação da Zona de Falha de Cássia. O referido pacote sedimentar apresenta-se localmente cortado por fraturas, zonas brechadas e falhas, caracterizando atividade neotectônica na região. Além disso, foi mostrada a forte influência da zona de falha no desenvolvimento da paisagem da região, sendo constatada a inversão do relevo e da drenagem na área estudada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudou-se a anatomia dos órgãos foliares (folhas basais, ou catafilos, no caso de folhas ausentes, e brácteas involucrais) de três espécies de Mapania Aubl. Os espécimes de Mapania macrophylla (Boeck) H.Pfeiff. e M. pycnostachya (Benth.) T.Koyama, pertencentes à seção Pycnocephala, e M. sylvatica Aubl., pertencente à seção Mapania, foram coletados durante expedições científicas na Reserva Florestal Ducke em Manaus, AM, e constituem representantes de um mesmo gênero que ocupam três ambientes distintos da Floresta Amazônica. Em todos os órgãos, as espécies apresentam epiderme uniestratificada, com células de paredes delgadas, e estômatos paracíticos na face abaxial, no mesmo nível ou um pouco acima das demais células epidérmicas. O mesofilo é homogêneo e apresenta dois padrões distintos nos órgãos foliares: o primeiro com feixes vasculares em um único nível, sem extensão de bainha, idioblastos fenólicos abundantes e aerênquima não conspícuo; e o segundo padrão com feixes vasculares maiores e menores intercalados, com extensão de bainha do feixe e interrompidos por aerênquima conspícuo com células translúcidas. O primeiro padrão foi encontrado em brácteas involucrais de M. sylvatica e o segundo em todos os órgãos foliares das demais espécies. Essa diferença corrobora com as seções estabelecidas e é importante na diferenciação de espécies dentro do gênero. No pseudopecíolo de M. pycnostachya foi observada a presença de hipoderme, caráter importante na diferenciação de Mapania e Hypolytrum e que, portanto, necessita ser melhor estudado no gênero. Ainda, a presença de aerênquima, células epidérmicas com parede delgada e posição dos estômatos refletem a adaptação dessas espécies a ambientes úmidos de várzea e igapó onde são encontradas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents the radiometric parameters determined by the medical physicist during routine radiotherapy planning service in cases of breast cancer . The contours of the breast volume in patients undergoing radiation breast tumors at the Hospital das Clinicas, Faculty of Medicine , UNESP, Botucatu ( HCFMB ) during the year 2012 were analyzed . In order to analyze the influence of physical and radiometric parameters for the determination of the dose distribution of irradiated breast volume , four measurements of isodose curves were prepared in four different heights breast , and compared with the isodose curves plotted computationally . In the routine of planning , the medical physicist must determine the isodose curve that gives the best dose distribution homogeneity in the irradiated volume . The choice of the treatment plan can be done by dedicated computer systems , which require significantly costly investments available services having better financial support . In the Service of Medical Physics , Department of Radiotherapy , HC FMB , we use a two-dimensional software for determination of isodose curves , however , this software is out of date and frequently becomes inoperable due to the lack of maintenance and it is a closed system without feasibility of interference from computer professionals . This fact requires manual preparation of isodose curves , which are subject to uncertainties due to the subjectivity in the clinical interpretation of medical radiation oncologist and medical physicist responsible for planning , plus dispendiar significant calculation time . The choice of the optimal isodose curve depends on the energy of the radiation beam , the geometry and dimensions of the irradiated area . The contours of the breast studied in this work evaluations showed that , for a given energy input , such as the energy of 1.25 MeV of gamma radiation Unit Telecobaltoterapia , the determination of the percentage depth dose ( PDP ) ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology