353 resultados para disk amplifiers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report the development of a tube amplifier built to be used in magnetic probe diagnostic of plasma. The probe is used to measure the magnetic field in the theta-pinch system presently running in our university. We present the calculations and procedures to determine the configuration of circuits and specify the components of the power supply, the preamp stage and the power stage. The circuit configuration and the characteristics of the components was obtained. A representative model of the system behavior gave the transfer function of the amplifier. Theoretical predictions of frequency response and the feedback effects were compared to the experimental values and showed very good agreement. The amplifier works between a frequency bandwidth of 20 an 30 kHz and supply a maximum power of 12 W

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The catalytic function of extended-spectrum β-lactamases can result in high degrees of bacterial resistance to β-lactamic antimicrobials and in the emergence of ESBL among the members of Enterobacteriaceae family, especially Klebsiella pneumoniae and Escherichia coli. This occurs due to the dissemination and emergence of new variants of these enzymes caused by the high utilization of antibiotics like broad-spectrum cephalosporins. The ESBL are β-lactamases capable of conferring bacterial resistance to the penicillins, 1st, 2nd and 3rd generation cephalosporins, and aztreonam (but not cephamycins and carbapenems) through the hydrolysis of these antibiotics. In view of this phenomenon, the exact screening and detection of the producers of ESBL are essential for the appropriate selection of the antimicrobial therapy. The purposes of this study were to evaluate the best antimicrobial for the selection of ESBL producers and to determine the best method for the detection of such microorganisms. We evaluated 200 sequential bacterial samples including the species Klebsiella pneumoniae (56.5%), Escherichia coli (34%), Proteus mirabilis (8.5%) and Klebsiella oxytoca (1%), previously characterized as ESBL producers between February and September 2008 in the Laboratory of Microbiology, Botucatu Medical School - UNESP, Botucatu, São Paulo State, Brazil. To select the ESBL-producer bacteria, we used the disks recommended by CLSI 2008, aztreonam (ATM), cefpodoxime (CPD), ceftriaxone (CRO), cefotaxime (CTX) and ceftazidime (CAZ), besides cefepime (FEP). ESBL production was confirmed by three methods: double disk screening, ESBL Etest®, and Vitek® automated system. The disks employed in the double disk screening were: penicillin associated with β-lactamase inhibitor, amoxicillin-clavulanic acid, and two β-lactamic antibiotics, ceftazidime and cefotaxime...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study the semi-quantitative and quantitative technique in the diagnosis of catheter-related infections in newborns and to determine oxacillin resistance in Staphylococcus isolated. It was analyzed 353 catheter tips from 273 newborns in the Neonatal Unit of Hospital FMB. To confirm the diagnosis of infection, were analyzed the clinical data of newborns, the presence of at least one positive blood culture and growth of ≥ 1000 CFU/mL on quantitative culture and/or ³15 UFC on semiquantitative culture, with the same microorganism isolation (species and drug sensitivity) in blood culture and no other focus of infection except the catheter. The disk diffusion technique was used to check similarity of strains and resistance to oxacillin. Of the 353 tips analyzed, 39 were included in this study as the inclusion criteria. The semiquantitative culture was positive in 26 (66.7%) catheters and quantitative culture was positive in 24 (61.5%). Of 273 patients, 19 (6.9%) had a diagnosis of catheter-related bloodstream Infection (CR-BSI). Of the 19 episodes of CR-BSI, S. epidermidis was the predominant etiological agent (84.2%). The resistance to the antibiotic methicillin was found in 14 (73.7%) strains of Staphylococcus. The semiquantitative method was more sensitive (79%) compared with the quantitative method (63%). The use of antibiotics may have influenced the sensitivity of the quantitative method as the microorganisms present in the lumen are exposed to higher concentrations of antibiotics administered via the catheter

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Baja SAE competitions challenge engineering students to design and build offroad vehicles, preparing them for the competitive job market. This monograph aims to study a part of the braking of a Baja SAE vehicle system, the brake disc. Giving attention to the wear suffered by discs of two different materials, steel 1045 and stainless steel 304, helping the team Piratas do Vale Bardahl in the best selection between them. Braking tests were performed on a test bench. Both discs have suffered the same braking conditions. Brake pads material, brake line pressure, braking time, number of braking, were parameters which were repeated in the testing of different types of disk, in order to ensure a high power comparison between the obtained data. Before and after the disk tests were weighed and measured, to make a comparison. After the brake tests, the disks were subjected to hardness and surface roughness testing. With the data collected and observations made in the worn parts, the comparison between these two materials was made, obtaining a selection of the best material for the team. The tests showed that steel 1045 has more advantages, compared to stainless steel 304, when applied to brake discs, on the tested conditions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article talks about the relationship between the body and sign, from the ideas of the Bakhtin Circle. The corpus analyzed is the spectacle Body (2000), designed from a disk of the same title (2000), by Arnaldo Antunes (AA). The aim is to reflect on the expressiveness of the body as a sign and the signic body, since the dialogue between the word (the song) and the body in action makes up the human architectural spectacle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporomandibular joint disorders causing limitation of mouth opening and pain may be related to the restriction of slipping or forward displacement of the mandibular condyle. Temporomandibluar arthrocentesis is the lavage of the joint and is regarded as a simple method that produces good results in patients with these symptoms. This article reports a case of disc displacement and closed lock in a patient who reported limited mouth opening and pain as the main symptoms. The treatment proposed was arthrocentesis and lavage, combining a corticosteroid with a sodium hyaluronate solution. It is concluded that arthrocentesis is a simple, efficient and barely invasive method for particular types of temporomandibular joint disorders and should be considered before opting for more invasive surgical procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim The aim of the present study was to evaluate the effect of surface roughness (roughness average [Ra] μm) on the hydrophobicity of a denture-base acrylic resin and the initial adherence and biofilm formation of Candida albicans (C. albicans). Methods Disk-shaped specimens were divided into six groups: Ra 0.05, Ra 0.2, Ra 0.4, Ra 0.8, Ra 1.5, and Ra 3.0. Water contact angles (WCA) were measured, and the specimens incubated with C. albicans for 90 min (initial adherence, n = 108) or 48 h (biofilm formation, n = 108). Adhered and biofilm cells were evaluated by c.f.u./mL and 2,3-bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide (XTT), and the correlation between the two methods was evaluated. The surface of the specimens and cells (adhered and biofilm) were also analyzed by scanning electron microscopy (SEM). Results Groups Ra 0.05 and 3.0 exhibited the lowest (~75°) and the highest (~100°) WCA mean values, respectively. For both initial adherence and biofilm formation, no statistically-significant differences were observed among all groups, as determined by c.f.u./mL and XTT. A positive correlation between these two methods was found. SEM analysis showed the presence of scratches and valleys on the acrylic specimens and densely-packed yeast cells covering the entire surface. Conclusions Roughness significantly increased hydrophobicity (WCA), but had no effect on the number and metabolic activity of adherent and biofilm cells of C. albicans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study aims to evaluate the degree of conversion (DC) and hydrolytic degradation through the Vickers hardness test (HV) of a nanofilled (Filtek™ Z-250, 3M) and a microhybrid (Filtek™Supreme-XT, 3M) composite resin. Materials and methods: Eight disk-shaped specimens (4 mm diameter × 2 mm thick, ISO 4049) of each material were prepared for each test. Composites were inserted into single increment in a metallic matrix and light-cured for 40 seconds. VH readings were performed for each specimen at predetermined intervals: immediately after polymerization (control), 1, 2, 3, 7, 14, 21, 30 and 180 days. After curing, initial hardness measurements were performed and the specimens were immersed in artificial saliva at 37°C. For DC (%), specimens were ground, pressed with KBr and analyzed by FT-IR spectrophotometer. Results: Student t-test showed that there was no difference between the resins for DC (p = 0.252). ANOVA analysis revealed that Z-250 VH means were all greater than S-XT, for both top and bottom surfaces, whatever the storage-period in artificial saliva (p < 0.001). After 180 days of storage, the hardness obtained for S-XT was similar with that at the baseline, for both top and bottom surfaces. While for Z-250 hardness was not significantly different from baseline only for top surface, but there was a significant decrease observed in hardness for bottom surface. Conclusion: The materials tested showed no evidence of hydrolytic degradation in a significant way, in a 6-month storagetime in artificial saliva. Nanofilled resin presents a monomer conversion comparable to the conventional microhybrid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)