311 resultados para Variance analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass® 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate®), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p<0.05). Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass® and single-phase Biosilicate® implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate® cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass® implants. Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass® 45S5 and single-phase Biosilicate®. The authors agree these implants might be useful in the management of the anophthalmic socket. © 2012 Informa Healthcare USA, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Body size is directly related to the productive and reproductive performance of beef cattle raised under free-range conditions. In an attempt to better plan selection criteria, avoiding extremes in body size, this study estimated the heritabilities and genetic correlations of yearling hip height (YH) and mature hip height (MH) with selection indices obtained at weaning (WI) and yearling (YI) and mature weight (MW). Data from 102,373 Nelore animals born between 1984 and 2010, which belong to 263 farms that participate in genetic evaluation programmes of beef cattle conducted in Brazil and Paraguay, were used. The (co)variance components and genetic parameters were estimated by Bayesian inference in multi-trait analysis using an animal model. The mean heritabilities for YH, MH and MW were 0. 56 ± 0. 06, 0. 47 ± 0. 02 and 0. 42 ± 0. 02, respectively. The genetic correlation of YH with WI (0. 13 ± 0. 01) and YI (0. 11 ± 0. 01) was practically zero, whereas a higher correlation was observed with MW (0. 22 ± 0. 03). Positive genetic correlations of medium magnitude were estimated between MH and WI and YI (0. 23 ± 0. 01 and 0. 43 ± 0. 02, respectively). On the other hand, a high genetic correlation (0. 68 ± 0. 03) was observed between the indicator traits of mature body size (MH and MW). Considering the top 20 % of sire (896 sires) in terms of breeding values for the yearling index, the rank sire correlations between breeding values for MH and MW was 0. 62. In general, the results indicate that selection based on WI and YI should not lead to important changes in YH. However, an undesired correlated response in mature cow height is expected, particularly when selection is performed using YI. Therefore, changes in the body structure of Nelore females can be obtained when MH and MW is used as a selection criterion for cows. © 2012 Institute of Plant Genetics, Polish Academy of Sciences, Poznan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exposure of rodents to an open elevated plus-maze (oEPM) elicits antinociception and increases plasma corticosterone levels. However, no studies have yet assessed the defensive behaviour repertoire of animals in this modified test. In Experiment 1, factor analysis was employed to characterise the behavioural profile of mice exposed to the oEPM. Experiments 2 and 3 assessed the effects of acute alprazolam (0.5-1.5. mg/kg; diazepam 0.5-1.5. mg/kg), pentylenetetrazole (10.0-30.0. mg/kg), yohimbine (2.0-6.0. mg/kg), mCPP (0.3-3.0. mg/kg), and acute and chronic fluoxetine (10.0-30.0. mg/kg) and imipramine (1.0-15.0. mg/kg) on behaviours identified in Experiment 1. The factor analyses revealed that behaviour in the oEPM can largely (77% total variance) be accounted for in terms of 3 factors: factor 1 ('. depth exploration'; e.g. head-dipping on the arms), factor 2 ('. cautious exploration of arms'; e.g. flatback approach), and factor 3 ('. risk assessment'; stretched attend postures - SAP). Experiments 2 and 3 showed that, over the dose range used, alprazolam selectively attenuated all measures of defensiveness. Similar, though more modest, effects were seen with diazepam. Confirming the intensity of the emotional response to the oEPM (nociceptive, endocrine and behavioural), relatively few significant behavioural changes were seen in response to the anxiogenic compounds tested. Although acute fluoxetine or imipramine treatment failed to modify behaviour in the oEPM, chronic fluoxetine (but not chronic imipramine) attenuated total flat back approach and increased head dipping outside the central square. Together, the results indicate that the oEPM induces behavioural defensive responses that are sensitive to alprazolam and chronic fluoxetine. © 2013 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of different beverages on acrylic resin denture teeth color degradation is evaluated. Ten acrylic resin denture teeth brands were evaluated: Art Plus (AP), Biolux (BX), Biotone IPN (BI), Magister (MG), Mondial 6 (MD), Premium 6 (PR), SR Vivodent PE (SR), Trilux (TR), Trubyte Biotone (TB), and Vipi Dent Plus (VP). Teeth were immersed in staining solutions (coffee, cola, and orange juice) or artificial saliva (control) (n = 6) for 1, 7, 15, or 30 days. Specimen colors were evaluated spectrophotometrically based on the Commission Internationale d'Eclairage L*a*b* system. Color differences (Delta E) were calculated between the baseline and post-staining results. Data were evaluated by analysis of variance and Tukey test (alpha = 0.05). BI (1.82 +/- 0.95) and TR (1.78 +/- 0.72) teeth exhibited the greatest Delta E values, while BX (0.88 +/- 0.43) and MD (1.09 +/- 0.44) teeth were the lowest, regardless of solution and measurement period, and were different from BI and TR teeth (P < 0.05). Cola and coffee promoted higher denture teeth color alterations than orange juice and saliva (P < 0.05). Saliva generated the lowest denture teeth color alterations. Greater immersion times caused higher denture teeth color changes. The lifespan of removable dentures and the aesthetic satisfaction of several edentulous patients may be increased with the use of stain-resistant artificial denture teeth. (C) The Authors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The purpose of this study is to analyze the tension distribution on bone tissue around implants with different angulations (0 degrees, 17 degrees, and 30 degrees) and connections (external hexagon and tapered) through the use of three-dimensional finite element and statistical analyses.Methods: Twelve different configurations of three-dimensional finite element models, including three inclinations of the implants (0 degrees, 17 degrees, and 30 degrees), two connections (an external hexagon and a tapered), and two load applications (axial and oblique), were simulated. The maximum principal stress values for cortical bone were measured at the mesial, distal, buccal, and lingual regions around the implant for each analyzed situation, totaling 48 groups. Loads of 200 and 100 N were applied at the occlusal surface in the axial and oblique directions, respectively. Maximum principal stress values were measured at the bone crest and statistically analyzed using analysis of variance. Stress patterns in the bone tissue around the implant were analyzed qualitatively.Results: The results demonstrated that under the oblique loading process, the external hexagon connection showed significantly higher stress concentrations in the bone tissue (P < 0.05) compared with the tapered connection. Moreover, the buccal and mesial regions of the cortical bone concentrated significantly higher stress (P < 0.005) to the external hexagon implant type. Under the oblique loading direction, the increased external hexagon implant angulation induced a significantly higher stress concentration (P = 0.045).Conclusions: The study results show that: 1) the oblique load was more damaging to bone tissue, mainly when associated with external hexagon implants; and 2) there was a higher stress concentration on the buccal region in comparison to all other regions under oblique load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Investigation and discrimination of neuromuscular variables related to the complex aetiology of low back pain could contribute to clarifying the factors associated with symptoms. Objective: Analysing the discriminative power of neuromuscular variables in low back pain. Methods: This study compared muscle endurance, proprioception and isometric trunk assessments between women with low back pain (LBP, n=14) and a control group (CG, n=14). Multivariate analysis of variance and discriminant analysis of the data were performed. Results: The muscle endurance time (s) was shorter in the LBP group than in the CG (p=0.004) with values of 85.81 (37.79) and 134.25 (43.88), respectively. The peak torque (Nm/kg) for trunk extension was 2.48 (0.69) in the LBP group and 3.56 (0.88) in the GG (p=0.001); for trunk flexion, the mean torque was 1.49 (0.40) in the LBP group and 1.85 (0.39) in the CG (p=0.023). The repositioning error (degrees) before the endurance test was 2.66 (1.36) in the LBP group and 2.41 (1.46) in the CG (p=0.664), and after the endurance test, it was 2.95 (1.94) in the LBP group and 2.00 (1.16) in the CG (p=0.06). Furthermore, the variables showed discrimination between the groups (p=0.007), with 78.6% of the individuals with low back pain correctly classified in the LBP group. In turn, variables related to muscle activation showed no difference in discrimination between the groups (p=0.369). Conclusion: Based on these findings, the clinical management of low back pain should consist of both resistance and strength training, particularly in the extensor muscles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed at evaluating the validity, reliability, and factorial invariance of the complete (34-item) and shortened (8-item and 16-item) versions of the Body Shape Questionnaire (BSQ) when applied to Brazilian university students. A total of 739 female students with a mean age of 20.44 (standard deviation = 2.45) years participated. Confirmatory factor analysis was conducted to verify the degree to which the one-factor structure satisfies the proposal for the BSQ's expected structure. Two items of the 34-item version were excluded because they had factor weights (lambda)< 40. All models had adequate convergent validity (average variance extracted =.43-.58; composite reliability=.85-.97) and internal consistency (alpha =.85-.97). The 8-item B version was considered the best shortened BSQ version (Akaike information criterion = 84.07, Bayes information criterion = 157.75, Browne-Cudeck criterion= 84.46), with strong invariance for independent samples (Delta chi(2)lambda(7)= 5.06, Delta chi(2)Cov(8)= 5.11, Delta chi(2)Res(16) = 19.30). (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Genética e Melhoramento Animal - FCAV