33 resultados para tip clearance
Pharyngeal clearance and pharyngeal transit time determined by a biomagnetic method in normal humans
Resumo:
Clearance and transit time are parameters of great value in studies of digestive transit. Such parameters are nowadays obtained by means of scintigraphy and videofluoroscopy, with each technique having advantages and disadvantages. In this study we present a new, noninvasive method to study swallowing pharyngeal clearance (PC) and pharyngeal transit time (PTT). This new method is based on variations of magnetic flux produced by a magnetic bolus passing through the pharynx and detected by an AC biosusceptometer (ACB). These measurements may be performed in a simple way. cause no discomfort. and do not use radiation. We measured PC in 8 volunteers (7 males and I female. 23-33 years old) and PTT in 8 other volunteers (7 males and I female. 21-29 years old). PC was 0.82 +/- 0.10 s (mean +/- SD) and PTT was 0.75 +/- 0.03 s. The results were similar for PC but longer for PTT than those determined by means of other techniques. We conclude that the biomagnetic method can be used to evaluate PC and PTT.
Resumo:
Unsteady flow of oil and refrigerant gas through radial clearance in rolling piston compressors has been modeled as a heterogeneous mixture, where the properties are determined from the species conservation transport equation coupled with momentum and energy equations. Time variations of pressure, tangential velocity of the rolling piston and radial clearance due to pump setting have been included in the mixture flow model. Those variables have been obtained by modeling the compression process, rolling piston dynamics and by using geometric characteristics of the pump, respectively. An important conclusion concerning this work is the large variation of refrigerant concentration in the oil-filled radial clearance during the compression cycle. That is particularly true for large values of mass flow rates, and for those cases the flow mixture cannot be considered as having uniform concentration. In presence of low mass flow rates homogeneous flow prevail and the mixture tend to have a uniform concentration. In general, it was observed that for calculating the refrigerant mass flow rate using the difference in refrigerant concentration between compression and suction chambers, a time average value for the gas concentration should be used at the clearance inlet.
Resumo:
This study assessed cavity preparations produced with different air abrasion tip parameters. Twelve test groups of extracted teeth were prepared to evaluate the parameters of 80 degrees or 45 degrees nozzle angles and 0.38 or 0.48 mm inner tip diameters. All other factors were held constant. A device was made to hold the specimen and air abrasion handpiece that standardized the distance and position relative to the tooth and time of application. The cavities were evaluated by assessing the rounding of the cavosurface margins and cavity floor. Measurements of cavosurface angles and the angle of concavity were made at the deepest portion of the abraded surface using scanning electron micrographs. The cavosurface angles were compared using paired t-test, and the effects of the tip design parameters were analyzed by ANOVA and Duncan's Multiple Range test. From the cavity patterns found in this study, the authors suggest that 80 degrees angle tips are more appropriate than 45 degrees angle tips for making narrow, deep cuts for preventive resin restorations. Conversely, when shallow preparations are needed, as in the case of Class V cavity preparations, cutting patterns of 45 degrees angle tips are more suitable.
Resumo:
The shape modes of a damped-free beam model with a tip rotor are determined by using a dynamical basis that is generated by a fundamental spatial free response. This is a non-classical distributed model for the displacements in the transverse directions of the beam which turns out to be coupled through boundary conditions due to rotation. Numerical calculations are performed by using the Ritz-Rayleigh method with several approximating basis.
Resumo:
The influence of endometrial cavity length (ECL) on implantation and pregnancy rates after 400 embryo transfers was studied prospectively in a population with the indication of IVF/intracytoplasmic sperm injection (ICSI). The tip of the transfer catheter was placed above or below the half point of the ECL in a randomized manner. Two analyses were performed: (i) absolute position (AP); embryo transfers were divided into three groups according to the distance between the end of the fundal endometrial surface and the catheter tip (DTC - distance tip catheter): AP 1 (n = 212), 10-15 mm; AP 2 (n = 158), 16-20 mm; and AP 3 (n = 30), ≥21 mm. (ii) relative position (RP) - embryo transfers were divided into four groups according to their RP [RP = (DTC/ECL) × 100]: RP 1 (n = 23), ≤40%; RP 2 (n = 177), 41-50%; RP 3 (n = 117), 51-60%; and RP 4 (n = 83), ≥61%. Analysis based on relative distance revealed significantly higher implantation and pregnancy rates (P < 0.05) in more central areas of the ECL. However, analysis based on absolute position did not reveal any difference. In conclusion, the present results demonstrated that implantation and pregnancy rates are influenced by the site of embryo transfer, with better results being obtained when the catheter tip is positioned close to the middle area of the endometrial cavity. In this respect, previous analysis of the ECL is the fundamental step in establishing the ideal site for embryo transfers.
Resumo:
A total of 640 one-day-old male Cobb chicks were used to evaluate the effects of early feed restriction and glutamine on villi density and tip surface of enterocytes in the small intestine of broilers. A two-factor factorial experimental design with glutamine and feed restriction as main factors was used. Treatments consisted of quantitative feed restriction at 30% of ad libitum intake from 7 to 14 days of age, and glutamine addition at 1% in the diet from 1 to 28 days of age. Sections of the small intestine (duodenum, jejunum, ileum) were collected at 14 and 21 days of age for analyses by scanning and transmission electron microscopy. Villi density decreased with age and increased in cranial-caudal direction. Glutamine increased villi density in the small intestine. Microvilli density and height decreased with age. Glutamine increased microvilli width. The jejunum was the segment with the largest surface area of the tip of the enterocytes, followed by the duodenum and the ileum. Feed restriction decreased the surface area of the tip of the enterocytes in the small intestine at 14 and at 21 days of age. Glutamine supplemented in the feed increased the surface area of the tip of the enterocytes of the jejunum and ileum at 21 days of age. © Asian Network for Scientific Information, 2007.
Resumo:
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.
Resumo:
The aim of this paper was to compare the dentin-pulp complex response to cavity preparation in human teeth using ultrasonic chemical vapor deposition (CVD) diamond tip and high-speed diamond bur. Class V buccal cavities were randomly prepared in 40 premolars from 14 patients aged 11 to 15 years. The cutting time was recorded and the cavities had the axial walls protected with gutta-percha and were filled with glass ionomer cement. The teeth were extracted at intervals of 0, 5, 10 and 20 days, and were decalcified, sectioned and stained by Hematoxylin & Eosin, Masson's Trichrome and Brown & Brenn techniques. The inflammatory response and cell disorganization were blindly evaluated by two examiners. The remaining dentin thickness (RDT) was measured by a linear scale using computer software. Statistical analysis by one-way ANOVA showed no statistically significant difference (P≤0.05) among the cavities prepared with either type of instrument, with mean RDT of 1132.50 mm. Cutting time and the pulp-dentin complex responses were analyzed statistically by Kruskal-Wallis and Dunn tests (P≤0.05). The ultrasonic CVD diamond tip took 5 times longer to prepare the cavities and there were no typical inflammatory pulp responses in cavities prepared with either type of cutting instrument, only mild to moderate cell disorganization was present. Even taking longer to cut the dental substrate, the ultrasonic CVD diamond tip produced similar pulp response compared to the conventional high-speed diamond bur.
Resumo:
Background: Smoking impairs mucociliary clearance and increases respiratory infection frequency and severity in subjects with and without smoking-related chronic lung diseases. Objective: This study evaluated the effects of smoking intensity on mucociliary clearance in active smokers. Methods: Seventy-five active smokers were grouped into light (1-10 cigarettes/day; n = 14), moderate (11-20 cigarettes/day; n = 34) and heavy smokers (≥21 cigarettes/day; n = 27) before starting a smoking cessation programme. Smoking behaviour, nicotine dependence, pulmonary function, carbon monoxide in exhaled air (exCO), carboxyhaemoglobin (COHb) and mucociliary clearance measured by the saccharin transit time (STT) test were all evaluated. An age-matched non-smoker group (n = 24) was assessed using the same tests. Results: Moderate (49 ± 7 years) and heavy smokers (46 ± 8 years) had higher STT (p = 0.0001), exCO (p < 0.0001) and COHb (p < 0.0001) levels compared with light smokers (51 ± 15 years) and non-smokers (50 ± 11 years). A positive correlation was observed between STT and exCO (r = 0.4; p < 0.0001), STT and cigarettes/day (r = 0.3, p = 0.02) and exCO and cigarettes/day (r = 0.3, p < 0.01). Conclusion: Smoking impairs mucociliary clearance and is associated with cigarette smoking intensity. Copyright © 2013 S. Karger AG, Basel.
Resumo:
Aquaporins have important roles in various physiological processes in plants, including growth, development and adaptation to stress. In this study, a gene encoding a root-specific tonoplast intrinsic aquaporin (TIP) from Eucalyptus grandis (named EgTIP2) was investigated. The root-specific expression of EgTIP2 was validated over a panel of five eucalyptus organ/tissues. In eucalyptus roots, EgTIP2 expression was significantly induced by osmotic stress imposed by PEG treatment. Histochemical analysis of transgenic tobacco lines (Nicotiana tabacum SR1) harboring an EgTIP2 promoter:GUS reporter cassette revealed major GUS staining in the vasculature and in root tips. Consistent with its osmotic-stress inducible expression in eucalyptus, EgTIP2 promoter activity was up-regulated by mannitol treatment, but was down-regulated by abscisic acid. Taken together, these results suggest that EgTIP2 might be involved in eucalyptus response to drought. Additional searches in the eucalyptus genome revealed the presence of four additional putative TIP coding genes, which could be individually assigned to the classical TIP1-5 groups. © 2013 Elsevier B.V.
Resumo:
O presente trabalho compara os resultados obtidos da depuração da creatinina endógena de pacientes encaminhados por solicitação médica, realizados pelo Setor de Bioquímica Clínica do CRD-NAC Unesp com protocolo do procedimento de depuração implantado na rotina laboratorial, que utiliza dados da creatinina de sangue e urina (amostra de 24 horas), com os resultados obtidos, para os mesmos pacientes, a partir das fórmulas de Cockcroft-Gault, MDRD simplificada e CDK-EPI, onde não se utiliza os valores obtidos na amostra de urina de 24 horas. E, a partir dessa análise, verifica em que casos o resultado do exame sem a amostra de urina de 24 horas correlaciona-se com o resultado da depuração da creatinina endógena realizado como procedimento de rotina e quais seriam as prováveis variáveis interferentes na aplicação destas fórmulas utilizadas em casos específicos, conforme a necessidade na avaliação clínica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)