146 resultados para Transducer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circuit for transducer linearizer tasks have been designed and built using discrete components and it implements by: a Radial Basis Function Network (RBFN) with three basis functions. The application in a linearized thermistor showed that the network has good approximation capabilities. The circuit advantages is the amplitude, width and center.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tityus serrulatus, popularly known as yellow scorpion, is one of the most studied scorpion species in South America and its venom has supplied some highly active molecules. The effects of T. serrulatus venom upon the renal physiology in human showed increased renal parameters, urea and creatinine. However, in perfused rat kidney the effects were not tested until now. Isolated kidneys from Wistar rats, weighing 240-280 g, were perfused with Krebs-Henseleit solution containing 6% (g weight) of previously dialysed bovine serum albumin. The effects of T. serrulatus venom were studied on the perfusion pressure (PP), renal vascular resistance (RVR), urinary flow (UF), glomerular filtration rate (GFR), sodium tubular transport (%TNa+), potassium tubular transport (%TK+) and chloride tubular transport (%TCl-). Tityus serrulatus venom (TsV; 10 mu g/mL) was added to the system 30 min after the beginning of each experiment (n = 6). This 30 min period was used as an internal control. The mesenteric bed was perfused with Krebs solution kept warm at 37 T by a constant flow (4 mL/min), while the variable perfusion pressure was measured by means of a pressure transducer. The direct vascular effects of TsV (10 mu g/mL/min; n=6), infused at a constant rate (0.1 mL/min), were examined and compared to the infusion of the vehicle alone at the same rate. TsV increased PP (PP30'= 127.8 +/- 0.69 vs PP60' = 154.2 +/- 14 mmHg*, *p < 0.05) and RVR (RVR30' = 6.29 +/- 0.25 vs RVR60' = 8.03 +/- 0.82 mmHg/mL g(-1) min(-1)*, *p < 0.05), decreased GFR (GFR(30') =0.58 +/- 0.02 vs GFR(60') = 0.46 +/- 0.01 mL g(-1) min(-1)*, *p < 0.05) and UF (UF30' = 0.135 +/- 0.001 vs UF60' = 0.114 +/- 0.003 mL g(-1)min(-1)*, *p < 0.05). Tubular transport was not affected during the whole experimental period (120 min). on the other hand, the infusion of TsV (10 mu g/mL/min) increased the basal perfusion pressure of isolated arteriolar mesenteric bed (basal pressure: 74.17 +/- 3.42 vs TsV 151.8 +/- 17.82 mmHg*, *p < 0.05). TsV affects renal haemodynamics probably by a direct vasoconstrictor action leading to decreased renal flow. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi estabelecer o tempo de prenhez da paca por meio de ultra-sonografia. Nove pacas prenhes foram periodicamente acompanhadas com um transdutor eletrônico setorial bi-frequencial de 5,0 e 7,5 MHz, em modo B, desde a detecção ultra-sonográfica da vesícula embrionária ou do feto até o nascimento dos filhotes. Os animais foram colocados em uma gaiola de ferro de prensagem lateral e permaneceram em posição quadrupedal durante as sessões. Um pano escuro foi usado para cobrir a gaiola e frutas foram oferecidas durante o exame ultra-sonográfico para evitar reações agressivas. Quanto mais precocemente ocorreu a detecção de prenhez, maior foi o período de acompanhamento ultra-sonográfico até o nascimento dos filhotes. Apenas um filhote nasceu por parto, com 796,5 ± 74,36 gramas (valor médio ± desvio padrão da amostra) e 33,46 ± 0,60 centímetros (valor médio ± desvio padrão da amostra) de comprimento (entre a borda rostral do focinho e a extremidade distal da cauda). O período de prenhez da paca abrange 135 a 139 dias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new device was developed to hold linear transducers for transvaginal follicle aspiration. Efficacy of follicle aspiration was compared using a linear 6 MHz and a convex 5 MHz transducer. Fifty-five cows were submitted to follicle aspiration at random days of the estrous cycle. Aspirations were conducted with linear (n = 28) and convex (n = 38) transducers with 18 G needles at a negative pressure corresponding to 13 ml H2O/min. A greater number of follicles were aspirated using convex than to linear probe (12.4 versus 7.8, respectively, P < 0.05). Mean number of oocytes and recovery rates were similar for convex (5.4 and 48.6%) and linear (4.6 and 59.3%) transducers. Limited space between the linear transducer and needle guide restricted access to some portions of the ovary, reducing the number of follicles aspirated using a linear transducer. The newly developed adaptor allowed greater stability, holding the ovaries firmly against the linear transducer. This diminished mobility permitted a similar number of oocytes to be recovered with both transducers. In conclusion, this new adaptor provided a low cost alternative for routine follicle aspiration and oocyte recovery in cattle. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As informações da avaliação de mecanismos de abertura de sulco de semeadoras de plantio direto auxiliam as empresas no dimensionamento de ferramentas rompedoras do solo, que buscam menor requerimento energético. Este trabalho foi realizado num solo classificado como Latossolo Vermelho com o objetivo de avaliar tridimensionalmente os esforços dos mecanismos de abertura de sulco de semeadoras adubadoras de plantio direto. O delineamento experimental utilizado foi o de blocos ao acaso com cinco tratamentos, sendo cinco mecanismos de abertura de sulco (disco liso - DL, disco corrugado - DC, disco ondulado - DO, disco duplo - DD e haste sulcadora - H). Para mensurar os esforços dos mecanismos de abertura de sulco, foi utilizado um dinamômetro com sensibilidade nas direções horizontal, transversal e vertical e no momento fletor e torsor. A avaliação mostrou que a interação entre mecanismos de abertura de sulco e carga vertical não foi significativa, entretanto os fatores foram significativos quando analisados individualmente. O resultado individual dos mecanismos de abertura de sulco mostrou que o disco ondulado proporcionou maior área de mobilização do solo, a haste sulcadora apresentou o menor valor de força vertical e o disco duplo e a haste sulcadora obtiveram o menor esforço horizontal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi desenvolvido um conjunto de equipamentos com o objetivo de mapear as áreas infestadas por macrófitas aquáticas, auxiliando operações de manejo mecânico, as quais são realizadas por uma colhedora desenvolvida especificamente para essa finalidade. O conjunto de equipamentos foi constituído por um GPS com programa de correção diferencial, acoplado a um palmtop, um sistema com dois teclados ligados em dataloggers e um transdutor de deslocamento linear LT. O GPS, através do palmtop, proporcionava o mapeamento da área de deslocamento, auxiliando o operador na movimentação da máquina, otimizando a operação e evitando, dessa forma, a sobreposição das faixas de coleta na área a ser manejada. Um dos teclados monitorava a movimentação e operação da colhedora, além da presença de obstáculos, como tocos e bancos de areia, enquanto o outro gerava dados sobre a presença de determinada espécie de planta, como E. densa, E. najas e C. demersum, além do nível de infestação destas plantas. O transdutor, instalado na plataforma frontal da colhedora, se movimentava linearmente, gerando informações sobre a profundidade da coleta realizada. Dessa forma, pôde-se observar que o desenvolvimento desse conjunto de equipamentos foi de grande utilidade e auxiliou a operação de controle mecânico de áreas infestadas por macrófitas aquáticas imersas, possibilitando, assim, o planejamento de operações de manejo e controle subseqüentes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances have accelerated the development of biosensors for the analysis of specific gene sequences. In this kind of biosensor, a DNA probe is immobilized on a transducer and the hybridization with the target DNA is monitored by suitable methodology. In the present work, the streptavidin (STA) was encapsulated in thin films siloxane-poly(propylene oxide) hybrids prepared by sol-gel method and deposited on the graphite electrode surface by dip-coating process. Biotinylated 18-mer probes were immobilized through STA and a novel amperometric DNA biosensor for the detection and genotyping of the hepatitis C virus (genotypes 1, 2A/C, 2B and 3) is described. The HCV RNA from serum was submitted to reverse transcriptase-linked polymerase chain reaction (RT-PCR) and biotin-labeled cDNA was obtained. Thus, the cDNA was hybridized to the target-specific oligonucleotide probe immobilized on the graphite electrode surface and following the avidin-peroxidase conjugate was added. The enzymatic response was investigated by constant potential amperometry at -0.45 V versus Ag/AgCl using H2O2 and KI solutions. HCV RNA negative and positive controls and positive samples of sera patients were analyzed and the results were compared to commercial kit. The proposed methodology appeared to be suitable and convenient tool for streptavidin immobilization and diagnose of HCV disease. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new electrochemical hybridization biosensor protocol without an external indicator is described. The biosensor format involves the immobilization of inosine-substituted (guanine-free) probe onto the carbon paste transducer, and a direct chronopotentiometric detection of the duplex formation by the appearance of the guanine oxidation peak of the target. Such a use of the intrinsic DNA electrochemical response for monitoring hybridization events offers several advantages (over the common use of external indicators), including the appearance of a new peak, a Aat background, or simplicity. A 4 min short hybridization period allows a detection limit around 120 ng/ml. Performance characteristics of the sensor are described along with future prospects. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents recent improvements in a density measurement cell with a double-element transducer that can eliminate diffraction effects. A new mechanical design combined with the use of more appropriate materials has resulted in better parallelism between interfaces, more robust assembly, and chemical resistance. A novel method of signal processing, named energy method, is introduced to obtain the reflection coefficient, reducing sensitivity to noise and improving accuracy. The measurement cell operation is verified both theoretically, using an acoustic wave propagation model, and experimentally, using homogeneous liquids with different densities. The accuracy in the density measurement is 0.2% when compared with the measurements made with a pycnometer.