101 resultados para Termoluminescência (TL)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoluminescence (TL) response of Dy and Li doped 20CaB(4)O(7)-80CaB(2)O(4) (Wt%) glass-ceramic irradiated with ultraviolet (UV) radiation was studied. In order to act as TL activator ions, the Dy and Li ions were included in the matrix during the melting process to increase its TL efficiency. A single crystalline CaB2O4 phase was present in the glass-ceramic as determined by X-ray diffraction (XRD). The glass-ceramic 20CaB(4)O(7)-80CaB(2)O(4):Dy,Li wt% (named 20CBO7:Dy,Li) is a newly prepared TL material. Its thermoluminescent dosimetric characteristics have shown a linear response under UV radiation exposure and a good TL signal reproducibility, thus proving to be a promising material for using as an ultraviolet radiation dosimeter. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Os bloqueadores neuromusculares (BNM) são freqüentemente utilizados em anestesia pediátrica e não existe aquele considerado ideal. O objetivo deste trabalho foi avaliar o rocurônio, o atracúrio e o mivacúrio, em crianças, quanto ao tempo de latência e de recuperação, à interferência sobre as variáveis hemodinâmicas e às condições de intubação traqueal. MÉTODO: Sessenta e sete crianças, estado físico ASA I e II, com idade variando de 2 anos e 6 meses a 12 anos, foram anestesiadas com alfentanil (50 µg.kg-1), propofol (3 mg.kg-1), sevoflurano e N2O/O2 e divididas em três grupos: G1 = rocurônio 0,9 mg.kg-1 (n = 22); G2 = atracúrio 0,5 mg.kg-1 (n = 22) e G3 = mivacúrio 0,15 mg.kg-1 (n = 23). A monitorização do bloqueio neuromuscular foi realizada com o método de aceleromiografia no trajeto do nervo ulnar. Foram estudados: o tempo de latência (TL), a duração clínica (T25), o tempo de relaxamento (T75) e o índice de recuperação (T25-75). A pressão arterial média (PAM) e a freqüência cardíaca (FC) foram registradas em seis momentos, bem como as condições encontradas no momento da intubação traqueal. RESULTADOS: A mediana do TL foi de 0,6 minutos em G1, 1,3 minutos em G2 e 1,9 minutos em G3. A mediana do T25 foi em G1 = 38 minutos, G2 = 41,5 minutos e G3 = 8,8 minutos. A mediana do T75 foi em G1 = 57,7 minutos, G2 = 54,6 minutos e G3 = 13,6 minutos. A mediana do índice de recuperação (T25-75) foi em G1 = 19,7 minutos, G2 = 13,1 minutos e G3 = 4,8 minutos. As condições de intubação traqueal foram consideradas excelentes na maioria dos pacientes de ambos os grupos. Não houve modificações clínicas importantes da PAM e da FC. CONCLUSÕES: O rocurônio, 0,9 mg.kg-1, teve o menor tempo de latência e o mivacúrio, 0,15 mg.kg-1, o menor tempo de recuperação nos pacientes pediátricos anestesiados com sevoflurano. Também, o rocurônio, o mivacúrio e o atracúrio não determinaram alterações hemodinâmicas de importância clínica relevante e proporcionaram excelentes condições de intubação traqueal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine the entrance surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence (TL) dosimetry. Twenty seven radiologic exams of dogs of different breed and sizes were performed. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO(4):Dy) produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN). The entrance surface skin dose range evaluated in this type of procedure was between 0.43 mGy to small size dogs and 4.22 mGy to big size dogs with repeated exams. The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Specimens of the zipper sand skate Psammobatis extenta were collected in the region of Ubatuba off the northern coast of the State of São Paulo, Brazil, monthly for once year (January - December 2000), at 25- to 40-m isobaths. A total of 123 individuals were caught. The total length (TL) of females averaged 224.6 mm, and of males 217 mm. The overall sex ratio was 1:1. Analysis of the length-weight relationship indicated the existence of positive allometry in females, and isometry in males. The length at onset of sexual maturity was determined for both sexes; females reached sexual maturity at smaller sizes than males (TL50 = 230.7 and TL50 = 237.7 mm respectively). Females showed functional parity of both ovaries and uteri. Females that were pregnant or were carrying vitellogenic oocytes were observed during nine of 12 months of the survey, indicating a continuous reproductive cycle. Psammobatis extenta was most abundant from January to April, and again from June to October. Most individuals were collected at the 40-m isobath. Both adults and neonates were collected in the study area. However, adolescent skates were scarce, which either indicates differential occupation of the area, or suggests that the shallow waters of the continental shelf are used as breeding grounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A combined method for evaluating radon (Rn-222) and progeny (Pb-214 and Bi-214) in water was developed by using inexpensive alpha scintillation Counting and gamma ray spectrometry through NaI(Tl) scintillation detectors. A groundwater sample collected at the Pocos de Caldas alkaline massif in Brazil was submitted to the technique in order to assure its applicability by comparing the volumetric activities by different methods. Similar volumetric activity was determined for Pb-214 and Bi-214 in the sample analyzed that is compatible with the expected condition of radioactive equilibrium between these nuclides. The combined method was successfully used to analyze groundwater samples from Guarani aquifer in S (a) over tildeo Paulo State, Brazil, and the results of the measurements indicated that Pb-214 and Bi-214 provide useful information concerning the evaluation of the drinking water quality in terms of radiological aspects. This is because they are directly identified in the water samples, without the need of requiring the assumption of the establishment of the transient equilibrium condition with its parent Rn-222. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Espécimes de Rioraja agassizi foram mensalmente coletados em águas ao largo de Santos, sudeste do Brasil entre as latitudes 23º37'S e 27º40'S, desde março de 2005 até março de 2006. Um total de 278 machos e 1023 fêmeas foi capturado. A amplitude de profundidade de ocorrência foi 10-120 m, estando a espécie ausente em profundidades >120 m. A razão sexual favoreceu as fêmeas. A amplitude completa de comprimentos de R. agassizi esteve representada e oscilou nas fêmeas entre 16.0-59.4 cm comprimento e nos machos entre 13.0-47.2 cm. O tamanho médio das fêmeas foi significativamente maior do que dos machos. A distribuição de freqüência de comprimentos por amostras agrupadas foi assimétrica em ambos os sexos. As curvas da relação comprimento-largura foram sexualmente dimórficas. As fêmeas foram mais largas que os machos em todas as classes de comprimento maiores do que 25 cm. As curvas comprimento-peso total foram significativamente diferentes das curvas comprimento-peso eviscerado em ambos os sexos. As fêmeas foram mais pesadas do que os machos para uma determinada classe de comprimento. O coeficiente angular b foi <3 nos machos (alometría negativa) e nas fêmeas, mas com exceção da primavera, onde a alometría foi positiva (b>3). O fator de condição variou significativamente ao longo do ano em ambos os sexos.