71 resultados para REFRACTION
Resumo:
Background: Recently, there has been an increasing in the impact of oral health on atherosclerosis and subsequent cardiovascular disease. The aim of this study is to investigate the association between chronic periodontitis and cardiovascular risk markers.Methods: Forty patients with periodontitis and 40 healthy gender-, body mass index-, and age-matched individuals were compared by measuring total cholesterol, high-density lipoprotein, low-density lipoprotein, triglycerides, levels of cytokines, antibodies against oxidized low-density lipoprotein, thiobarbituric acid reactive substances, total and differential white blood cell counts, and the non-linear index of refraction.Results: The levels of triglycerides and high-density lipoprotein in periodontitis patients were significantly higher and lower, respectively (P=0.002 and P=0.0126), compared to controls. Total cholesterol, low-density lipoprotein, and lipid peroxide levels were the same in both groups (P = 0.2943, P = 0.1284, and P = 0.067, respectively). Interleukin (IL)-6 and -8, antibodies against oxidized low-density lipoprotein, and leukocyte and neutrophil counts were significantly higher in periodontitis patients (P<0.05). The value of the non-linear index of refraction of low-density lipoprotein solutions was higher in the controls (P = 0.015) compared to individuals with periodontitis.Conclusion: Our results confirmed and further strengthened the suggested association between coronary artery disease and periodontitis. J Periodontol 2009;80:378-388.
Resumo:
Silica-titania planar waveguides of different thicknesses and compositions have been produced by radio-frequency sputtering and dip coating on silica substrates. Waveguides were also produced by silver exchange on a soda-lime silicate glass substrate. Brillouin scattering of the samples has been studied by coupling the exciting laser beam with a prism to different transverse-electric (TE) modes of the waveguides, and collecting the scattered light from the front surface. In multimode waveguides, the spectra depend on the m mode of excitation. For waveguides with a step index profile, two main peaks due to longitudinal phonons are present, apart from the case of the TE0 excitation, where a single peak is observed. The energy separation between the two peaks increases with the mode index. In graded-index waveguides, m-1 peaks of comparable intensities are observed. The spectra are reproduced very well by a model which considers the space distribution of the exciting field in the mode, a simple space dependence of the elasto-optic coefficients, through the value of the refraction index, and neglects the refraction of phonons. A single-fit parameter, i.e., the longitudinal sound velocity, is used to calculate as many spectra as is the number of modes in the waveguide. (C) 2003 American Institute of Physics.
Resumo:
The optical nonlinearity of tungstate fluorophosphate glasses, synthesized in the NaPO3-BaF2-WO3 system, was investigated through experiments based on the third-order susceptibility, chi((3)). Nonlinear (NL) refraction and NL absorption measurements in the picosecond regime were performed using the Z-scan technique at 532 nm. NL refractive index, n(2)proportional toRe chi((3)), ranging from 0.4x10(-14) cm(2)/W to 0.6x10(-14) cm(2)/W were determined. The two-photon absorption coefficient, alpha(2)proportional toIm chi((3)), for excitation at 532 nm, vary from 0.3 to 0.5 cm/GW. Light induced birefringence experiments performed in the femtosecond regime indicate that the response time of the nonlinearity at 800 nm is faster than 100 fs. The experiments show that chi((3)) is enhanced when the WO3 concentration increases and this behavior is attributed to the hyperpolarizabilities associated to W-O bonds. (C) 2004 American Institute of Physics.
Resumo:
Glassy films of Ga10Ge25S65 with 4 mu m thickness were deposited on quartz substrates by electron beam evaporation. Photoexpansion (PE) (photoinduced increase in volume) and photobleaching (PB) (blue shift of the bandgap) effects have been examined. The exposed areas have been analyzed using perfilometer and an expansion of 1.7 mu m (Delta V/V approximate to 30%) is observed for composition Ga10Ge25S65 exposed during 180 min and 3 mW/cm(2) power density. The optical absorption edge measured for the film Ge25Ga10S65 above and below the bandgap show that the blue shift of the gap by below bandgap photon illumination is considerable higher (Delta E-g = 440 meV) than Delta E-g induced by above bandgap illumination (Delta E-g = 190 meV). The distribution of the refraction index profile showed a negative change of the refraction index in the irradiated samples (Delta n = -0.6). The morphology was examined using a scanning electron microscopy (SEM). The chemical compositions measured using an energy dispersive analyzer (EDX) indicate an increase of the oxygen atoms into the irradiated area. Using a Lloyd's mirror setup for continuous wave holography it was possible to record holographic gratings using the photoinduced effects that occur in them. Diffraction efficiency up to 25% was achieved for the recorded gratings and atomic force microscopy images are presented. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The photonic modes of Thue-Morse and Fibonacci lattices with generating layers A and B, of positive and negative indices of refraction, are calculated by the transfer-matrix technique. For Thue-Morse lattices, as well for periodic lattices with AB unit cell, the constructive interference of reflected waves, corresponding to the zero(th)-order gap, takes place when the optical paths in single layers A and B are commensurate. In contrast, for Fibonacci lattices of high order, the same phenomenon occurs when the ratio of those optical paths is close to the golden ratio. In the long wavelength limit, analytical expressions defining the edge frequencies of the zero(th) order gap are obtained for both quasi-periodic lattices. Furthermore, analytical expressions that define the gap edges around the zero(th) order gap are shown to correspond to the
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In rare earth ion doped solids, a resonant non-linear refractive index, n2, appears when the laser pumps one of the ion excited states and the refractive index change is proportional to the excited state population. In these solids there are usually thermal and non-thermal lensing effects, where the non-thermal one is due to the polarizability difference, Δα, between excited and ground states of the ions. We have used the time resolved Z-scan and a mode-mismatched thermal lens technique with an Ar+ ion laser in Er+3 (20ZnF2-20SrF2-2NaF-16BaF2-6GaF3-(36 - x)InF3-xErF3, with x= 1, 2, 3 and 4 mol%) and Nd+3 (20SrF2-16BaF2-20ZnF2-2GdF3-2NaF-(40 - x)InF3-xNdF3, with x = 0.1, 0.25, 0.5-1 mol%) doped fluoroindate glasses. In both samples we found that the non-linear refraction is due to the thermal effect, while the non-thermal effect is negligible. This result indicates that in fluoride glasses Δα is very small (less than 10-26 cm3). We also measured the imaginary part of the non-linear refractive index (n″2) due to absorption saturation.
Resumo:
Study model: observacional, retrospective. Objective: to determine the frequence of the ametropic errors and other ocular problems in children with 2 to 8 year-old at Piracicaba - SP. Patients and Method: During the school year of 2000, 1001 children enrolled at the public schools of Piracicaba - SP, age ranged from 2 to 8 years old, were referred to complete ophthalmological exam. Visual acuity was previously determined using Snellen chart, applied by school teachers. Those children presenting visual acuity equal or less than 0.8, visual complaints or visual disorders were selected to appointment. Results: 51 children (5.09%) did not attended to examination. 950 children were submitted to complete ophthalmological exam. Ametropic errors were found 70.84% of the children. The most prevalent refractive errors were Hypermetropic Astigmatism (49.62%) and Hypermetropia (32,98%). Anisometropia was found in 1.78% children. Other ocular disabilities accounted for 10.21% of the examined children, such as strabismus (3.36%), eyelid changes, allergic conjunctivitis, congenital dacryostenosis, optic atrophy, corioretinitis and congenital glaucoma. Conclusion: The frequence of ocular problems observed let us to conclude the screening programs are valid surveys on decreasing rates of preventable blindness in our country.
Resumo:
Illumination of photorefractive, iron-doped lithium niobate crystals (LiNbO 3:Fe) with x-rays generates a conductivity that we determine from the speed of hologram erasure. The doping levels of the crystals and the acceleration voltage of our x-ray tube are varied. A theoretical model is presented, which describes the obtained results. A decrease of the conductivity with increasing Fe 2+ concentration can be explained by assuming that holes are the dominant charge carriers for this short-wavelength illumination.
Resumo:
Systematic errors can have a significant effect on GPS observable. In medium and long baselines the major systematic error source are the ionosphere and troposphere refraction and the GPS satellites orbit errors. But, in short baselines, the multipath is more relevant. These errors degrade the accuracy of the positioning accomplished by GPS. So, this is a critical problem for high precision GPS positioning applications. Recently, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique. It uses a natural cubic spline to model the errors as a function which varies smoothly in time. The systematic errors functions, ambiguities and station coordinates, are estimated simultaneously. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method.
Resumo:
Purpose: To show the importance of the cicloplegic method in the refraction evaluation comparing the automated refraction (subjective and objective) and the subjective static refraction. Method: One-hundred patients (200 eyes) between 5 and 40 years were prospectivelly evaluated according the static and dynamic automated refraction and the subjective static refraction, using an automated refractor Nidek ARK - 900. The data were submitted to statical evaluation. Results: The concordance indices were better after cycloplegia mainly in relation of the spheric degree and cílindric axes. Conclusion: Cycloplegia is very important to have accurace in the automated refraction in patients before 40 year-old.
Resumo:
The GPS observables are subject to several errors. Among them, the systematic ones have great impact, because they degrade the accuracy of the accomplished positioning. These errors are those related, mainly, to GPS satellites orbits, multipath and atmospheric effects. Lately, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique (PLS). In this method, the errors are modeled as functions varying smoothly in time. It is like to change the stochastic model, in which the errors functions are incorporated, the results obtained are similar to those in which the functional model is changed. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method (CLS). In general, the solution requires a shorter data interval, minimizing costs. The method performance was analyzed in two experiments, using data from single frequency receivers. The first one was accomplished with a short baseline, where the main error was the multipath. In the second experiment, a baseline of 102 km was used. In this case, the predominant errors were due to the ionosphere and troposphere refraction. In the first experiment, using 5 minutes of data collection, the largest coordinates discrepancies in relation to the ground truth reached 1.6 cm and 3.3 cm in h coordinate for PLS and the CLS, respectively, in the second one, also using 5 minutes of data, the discrepancies were 27 cm in h for the PLS and 175 cm in h for the CLS. In these tests, it was also possible to verify a considerable improvement in the ambiguities resolution using the PLS in relation to the CLS, with a reduced data collection time interval. © Springer-Verlag Berlin Heidelberg 2007.
Resumo:
Nonlinear (NL) optical properties of antimony oxide based glasses (AG) were characterized for excitation wavelengths from 800 to 1600 m. The NL refractive indices, n2, and the two-photon absorption (TPA) coefficient, β, have been evaluated using the Z-scan technique. Values of n2≈ 10-15 - 10-14 cm2/W of electronic origin were measured and negligible TPA coefficients (β < 0.003 cm/GW) were determined. The response time of the nonlinearity is faster than 100 fs as determined using the Kerr shutter technique. The figure-of-merit usually considered for all-optical switching, T = 2βλ/n2 , indicates that AG are very good materials for ultrafast switches at telecom wavelengths. © 2007 IEEE.
Resumo:
We studied the shape measurement of semiconductor components by holography with photorefractive Bi12TiO20 crystal as holographic medium and two diode lasers emitting in the red region as light sources. By properly tuning and aligning the lasers a synthetic wavelength was generated and the resulting holographic image of the studied object appears modulated by cos2-contour fringes which correspond to the intersection of the object surface with planes of constant elevation. The position of such planes as a function of the illuminating beam angle and the tuning of the lasers was studied, as well as the fringe visibility. The fringe evaluation was performed by the four stepping technique for phase mapping and through the branch-cut method for phase unwrapping. A damage in an integrated circuit was analysed as well as the relief of a coin was measured, and a precision up to 10 μm was estimated. © 2009 SPIE.