22 resultados para Potentiometric ion sensors


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely Pt| Hg|Hg-2(DCF)(2)|graphite, where DCF stands for diclofenac ion, are described. This electrode responds to diclofenac with sensitivity of (58.1 +/- 0.8) mV/decade over the range 5.0 x 10(-5) to 1.0 x 10(-2) Mol l(-1) at pH 6.5-9.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode is easily constructed at a relatively low cost with fast response time (within 10-30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for diclofenac in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used to determine diclofenac in pharmaceutical preparations by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedures. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for saccharin determination in commercial artificial sweeteners is proposed. Saccharin present in several samples of artificial sweeteners is potentiometrically titrated with silver nitrate solution using a silver wire as the indicator electrode, coupled to a titroprocessor. The best pH range was from 3.0 to 3.5 and the detection limit of sodium saccharin was 2.5 mg/ml. Substances normally found along with saccharin in several commercial artificial sweeteners such as maltodextrin, glucose, sucrose, fructose, aspartame, cyclamate, caffeine, sorbitol, lactose, nitrate, methyl- and n-propyl-p-hydroxybenzoate, benzoic, citric and ascorbic acids do not interfere even in significant amounts (e.g. 20 excess relative to saccharin). Chloride ion interferes when present in concentrations larger than 10 mg l(-1); this interference is eliminated with previous extraction of the sweetener from the aqueous medium with ethyl acetate. The results obtained by applying the proposed method compared very favorably with those given by the HPLC method recommended by the FDA. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A potentiometric sensor for perchlorate anion was developed by mixing a silica gel, chemically modified with 1,4-diazabicyclo (2.2.2)octane, with an epoxy polymer and carbon. The electode showed Nernstian response to the perchlorate ion in the concentration range of 10(-1) and 10(-4) mol L-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A potentiometric sensor for the perchlorate anion was developed by mixing chemically modified silicagel with pyridinium perchlorate, with an epoxy polymer and graphite. The electrode showed Nernstian response between 1.0 × 10-2 and 1.0 × 10-3M perchlorate concentrations. The electrode showed high selectivity to this ion at solutions pH between 5.5 and 8.0. The presence of IO4 -, NO3 -,Br-, IO3 -, Cl- and SO4 2- ions in the solutions, had only small interference in the electrode response in the range mentioned. © 1995 Springer-Verlag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Potentiometric, amperometric and conductometric electrochemical sensors have found a number of interesting applications in the areas of environmental, industrial, and clinical analyses. This review presents a general overview of the three main types of electrochemical sensors, describing fundamental aspects, developments and their contribution to the area of analytical chemistry, relating relevant aspects of the development of electrochemical sensors in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)