60 resultados para Node placement
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, we consider the symmetric Gaussian and L-Gaussian quadrature rules associated with twin periodic recurrence relations with possible variations in the initial coefficient. We show that the weights of the associated Gaussian quadrature rules can be given as rational functions in terms of the corresponding nodes where the numerators and denominators are polynomials of degree at most 4. We also show that the weights of the associated L-Gaussian quadrature rules can be given as rational functions in terms of the corresponding nodes where the numerators and denominators are polynomials of degree at most 5. Special cases of these quadrature rules are given. Finally, an easy to implement procedure for the evaluation of the nodes is described.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
Resumo:
Objectives. The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer.Methods. Between July 2001 and February 2003, 56 patients with cervical cancer 1160 stage I (it 53) or stage 11 (it 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (Te-99m-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intratoperative lymphatic mapping with a handheld gamma probe, Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy, Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy.Results. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe, Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliae region, and 6.7),) in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (4100 had bilateral sentinel nodes, Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel node.,, that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% - 56.6-96.2) and the negative predictive value was 92.1% (CI 95% 78.6 98.3) the accuracy of sentinel node in predicting the lymph node status was 94.2%,Conclusion. Preoperative lymphoscintigraphy and intraoperative lymphatic mapping with Tc-99-labeled phytate are effective in identifying sentinel nodes in patients undergoing radical hysterectomy and to select women in whom lymph node dissection call be avoided. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Purpose: This study was undertaken to evaluate clinical and pathologic findings that predicted pelvic lymph node metastasis and parametrial and vaginal involvement in patients with stage IB carcinoma of the cervix. Methods: 71 patients with diagnosis of stage IB (FIGO) cervical cancer were prospectively studied from December 1997 to August 2002. The patient's age, clinical stage (IB1 or IB2), histological classification, grade of differentiation, tumor volume, and lymphatic vascular space invasion (LVSI) were evaluated. Statistical methods included chi(2) test and Fisher's exact test to evaluate significant differences between the groups. The level of significance was set at p < 0.05. Results: the clinical stage was IB1 in 51 patients (71.8%) and IB2 in 20 patients (28.2%). The histological classification identified squamous cell carcinoma in 60 patients (84.5%) and adenocarcinoma in 11 patients (15.5%). The average tumoral volume was 22.8 &PLUSMN; 8 24.3 cm(3) (0.3-140.0 cm(3)). The tumor was well differentiated (G1) in 8 (11.3%), moderately differentiated (G2) in 40 (56.3%) and poorly differentiated in 23 (32.4%) of the cases. The presence of LVSI was detected in 14 patients (19.7%) and was associated with pelvic lymph node metastasis and vaginal and parametrial involvement (p = 0.002, p = 0.001 and p < 0.001; respectively). The average number of positive pelvic lymph nodes was significantly higher in the patients with LVSI compared with patients without LVSI (2.47 +/- 2.8 vs. 0.33 +/- 0.74; p = 0.001). There was no association of age, clinical stage, histological classification, grade of differentiation or tumor volume with pelvic lymph node metastasis and vaginal and parametrial involvement. Conclusion: the presence of LVSI is significantly associated with pelvic lymph node metastasis and vaginal and parametrial involvement in patients with stage IB cervical carcinoma. Copyright (C) 2005 S. Karger AG, Basel.
Resumo:
The capacitor placement (replacement) problem for radial distribution networks determines capacitor types, sizes, locations and control schemes. Optimal capacitor placement is a hard combinatorial problem that can be formulated as a mixed integer nonlinear program. Since this is a NP complete problem (Non Polynomial time) the solution approach uses a combinatorial search algorithm. The paper proposes a hybrid method drawn upon the Tabu Search approach, extended with features taken from other combinatorial approaches such as genetic algorithms and simulated annealing, and from practical heuristic approaches. The proposed method has been tested in a range of networks available in the literature with superior results regarding both quality and cost of solutions.
Resumo:
The possibility of reducing morbidity associated with surgical dissection while maintaining accurate tumor staging is one of the greatest advantages of the sentinel node approach in surgical oncology. The sentinel node mapping has already proven to be useful in melanoma, breast cancer, and vulvar cancer. We report the first case of sentinel node detection by technetium-labeled radiocolloid in a pregnant woman with cervical cancer. The histologic analysis of the operative specimen showed a poorly differentiated squamous carcinoma with metastasis in the sentinel node and a neoplasic embolus in a blood vessel of the placental bed. The lymphatic mapping and sentinel lymph node detection are feasible during pregnancy.
Resumo:
Inferior Alveolar Nerve (IAN) transposition is an option for prosthetic rehabilitation in cases of moderate or even severe bone reabsorption for patients that do not tolerate removable dentures. The aim of the present report is to describe an inferior alveolar nerve transposition with involvement of the mental foramen for implant placement. The surgical procedure was performed under local anesthesia, by the inferior alveolar, lingual and buccal nerve blocking technique. Centripetal osteotomy was performed, and bone tissue was removed, leaving the nerve tissue free in the foramen area. After that, transsection of the incisor nerve was performed, and lateral osteotomy was started from the buccal direction, toward the trajectory of the IAN. The procedure was concluded, by making use of a delicate resin spatula to manipulate the vascular-nervous bundle. The drilling sequence for placing the dental implants was performed, and autogenous bone was harvested using a bone collector attached to the surgical suction appliance. After the implants were placed, the bone tissue previously collected during the osteotomies and drilling processes was placed in order to protect the IAN from contact with the implants. The surgical protocol for inferior alveolar nerve transposition, followed by implant placement presented excellent results, with complete recovery of the sensitivity, seven months after the surgical procedure.
Resumo:
This paper investigates both theoretically and experimentally the effect of the location and number of sensors and magnetic bearing actuators on both global and local vibration reduction along a rotor using a feedforward control scheme. Theoretical approaches developed for the active control of beams have been shown to be useful as simplified models for the rotor scenario. This paper also introduces the time-domain LMS feedforward control strategy, used widely in the active control of sound and vibration, as an alternative control methodology to the frequency-domain feedforward approaches commonly presented in the literature. Results are presented showing that for any case where the same number of actuators and error sensors are used there can be frequencies at which large increases in vibration away from the error sensors can occur. It is also shown that using a larger number of error sensors than actuators results in better global reduction of vibration but decreased local reduction. Overall, the study demonstrated that an analysis of actuator and sensor locations when feedforward control schemes are used is necessary to ensure that harmful increased vibrations do not occur at frequencies away from rotor-bearing natural frequencies or at points along the rotor not monitored by error sensors.
Resumo:
In the present study, we compared six different solubilization buffers and optimized two-dimensional electrophoresis (2-DE) conditions for human lymph node proteins. In addition, we developed a simple protocol for 2-D gel storage. Efficient solubilization was obtained with lysis buffers containing (a) 8 M urea, 4% CHAPS (3-[(3-cholamidopropyl) dimethylammonio]-1-propanesulfonate), 40 mM Tris base, 65 mM DTT (dithiothreitol) and 0.2% carrier ampholytes; (b) 5 M urea, 2 M thiourea, 2% CHAPS, 2% SB 3-10 (N-decyl-N,N-dimethyl-3-ammonio-1-propanesulfonate), 40 mM Tris base, 65 mM DTT and 0.2% carrier ampholytes or (c) 7 M urea, 2 M thiourea, 4% CHAPS, 65 mM DTT and 0.2% carrier ampholytes. The optimal protocol for isoelectric focusing (IEF) was accumulated voltage of 16,500 Vh and 0.6% DTT in the rehydration solution. In the experiments conducted for the sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), best results were obtained with a doubled concentration (50 mM Tris, 384 mM glycine, 0.2% SDS) of the SDS electrophoresis buffer in the cathodic reservoir as compared to the concentration in the anodic reservoir (25 mM Tris, 192 mM glycine, 0.1% SDS). Among the five protocols tested for gel storing, success was attained when the gels were stored in plastic bags with 50% glycerol. This is the first report describing the successful solubilization and 2D-electrophoresis of proteins from human lymph node tissue and a 2-D gel storage protocol for easy gel handling before mass spectrometry (MS) analysis.