36 resultados para IEC 61850
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Ciência da Computação - IBILCE
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
One of the main objectives of the Spanish and Portuguese-Speaking Group of the International Society for Forensic Genetics (GHEP-ISFG) is to promote and contribute to the development and dissemination of scientific knowledge in the area of forensic genetics. Due to this fact, GHEP-ISFG holds different working commissions that are set up to develop activities in scientific aspects of general interest. One of them, the Mixture Commission of GHEP-ISFG, has organized annually, since 2009, a collaborative exercise on analysis and interpretation of autosomal short tandem repeat (STR) mixture profiles. Until now, three exercises have been organized (GHEP-MIX01, GHEP-MIX02 and GHEP-MIX03), with 32, 24 and 17 participant laboratories respectively. The exercise aims to give a general vision by addressing, through the proposal of mock cases, aspects related to the edition of mixture profiles and the statistical treatment. The main conclusions obtained from these exercises may be summarized as follows. Firstly, the data show an increased tendency of the laboratories toward validation of DNA mixture profiles analysis following international recommendations (ISO/IEC 17025: 2005). Secondly, the majority of discrepancies are mainly encountered in stutters positions (53.4%, 96.0% and 74.9%, respectively for the three editions). On the other hand, the results submitted reveal the importance of performing duplicate analysis by using different kits in order to reduce errors as much as possible. Regarding the statistical aspect (GHEP-MIX02 and 03), all participants employed the likelihood ratio (LR) parameter to evaluate the statistical compatibility and the formulas employed were quite similar. When the hypotheses to evaluate the LR value were locked by the coordinators (GHEP-MIX02) the results revealed a minor number of discrepancies that were mainly due to clerical reasons. However, the GHEP-MIX03 exercise allowed the participants to freely come up with their own hypotheses to calculate the LR value. In this situation the laboratories reported several options to explain the mock cases proposed and therefore significant differences between the final LR values were obtained. Complete information concerning the background of the criminal case is a critical aspect in order to select the adequate hypotheses to calculate the LR value. Although this should be a task for the judicial court to decide, it is important for the expert to account for the different possibilities and scenarios, and also offer this expertise to the judge. In addition, continuing education in the analysis and interpretation of mixture DNA profiles may also be a priority for the vast majority of forensic laboratories. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Several countries have invested in technologies for Smart Grids. Among such protocols designed cover this area, highlights the DNP3 (Distributed Network Protocol version 3). Although the DNP3 be developed for operation over the serial interface, there is a trend in the literature to the use of other interfaces. The Zigbee wireless interface has become more popular in the industrial applications. In order to study the challenges of integrating of these two protocols, this article is presented the analysis of DNP3 protocol stack through state machines The encapsulation of DNP3 messages in P2P (point-to-point) ZigBee Network, may assist in the discovery and solution of failures of availability and security of this integration. The ultimate goal is to merge the features of DNP3 and Zigbee stacks, and display a solution that provides the benefits of wireless environment, without impairment of security required for Smart Grid applications.
Resumo:
Polymeric insulation is an increasing tendency in projects and maintenance of electrical networks for power distribution and transmission. Electrical power devices (e. g., insulators and surge arresters) developed by using polymeric insulation presents many advantages compared to the prior power components using ceramic insulation, such as: a better performance under high pollution environment; high hydrophobicity; high resistance to mechanical, electrical and chemical stresses. The practice with silicone insulators in polluted environments has shown that the ideal performance is directly related to insulator design and polymer formulation. One of the most common misunderstandings in the design of silicone compounds for insulators is the amount of inorganic load used in their formulation. This paper attempts to clarify how the variation of the inorganic load amount affects physicochemical characteristics of different silicone compounds. The physicochemical evaluation is performed from several measurements, such as: density, hardness, elongation, tensile strength. In addition, the evaluation of the physicochemical structure is carried out using infrared test and scanning electronic microscopy (SEM). The electrical analysis is performed from the electric tracking wheel and erosion test, in agreement with the recommendation of the International Electrotechnical Commission (IEC). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
This study aims to structurally evaluate a support of graphite pastille for the lubrication of railway wheels. The proper lubrication of wheel flanges of the railway extends the life of this component, so it is very important that this occurs lubrication to reduce the costs involved in railway maintenance. To prepar the evaluation structural will be used to International Electrotechnical Comission standard (IEC 61373) establishing which load cases should be applied to this component. The applied loads on the support (accordance with IEC) are random accelerations and accelerations due to shocks, thus simulating the conditions that exist along the route of the train. The structural analyzes are performed by the finite element method, with the aid of the Cosmos software. Thus, it is possible to determine the stresses acting on the support, and so the allowable stresses compared with the standard proposed by the AISC. The stress in the structural analyzes are lower than allowable therefore considered for the configuration presented, unexpected structural problems
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS