108 resultados para Hplc Method


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The acidic ninhydrin spectrophotometric method (ANSM) for quantitative determination of free and bound sialic acid of milk glycoprotein has been proved to be fast and efficient for routine detection of fraudulent addition of rennet whey to fluid milk. In this research the ANSM was compared with the high performance liquid chromatography (HPLC) method, internationally recommended for caseinomacropeptide (CMP) determination, which besides its high accuracy is more sophisticated and requires trained personnel. For several sample conditions (raw milk and milk with variable added amounts of rennet cheese whey), the methods showed an excellent linear correlation, with r = 0.981 when milk was deproteinized with a 120 g.L-1 final concentration of trichloroacetic acid (TCA) concentration. The best correlations could be seen with final concentrations of 100 g.L-1 and 80 g.L-1 TCA; respectively, r = 0.992 and 0.993.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A high-performance liquid chromatography (HPLC) method for the determination of acetaldehyde in fuel ethanol was developed. Acetaldehyde was derivatized with 0.900 mL 2,4-dinitrophenylhydrazine (DNPHi) reagent and 50 mu L phosphoric acid 1 mol L-1 at a controlled room temperature of 15 degrees C for 20 min. The separation of acetaldehyde- DNPH (ADNPH) was carried out on a Shimadzu Shim-pack C-18 column, using methanol/LiCl(aq) 1.0 mM (80/20, v/v) as a mobile phase under isocratic elution and UV-Vis detection at 365 nm. The standard curve of ADNPH was linear in the range 3-300 amg L-1 per injection (20 mu L) and the limit of detection (LOD) for acetaldehyde was 2.03 mu g L-1, with a correlation coefficient greater than 0.999 and a precision (relative standard deviation, RSD) of 5.6% (n=5). Recovery studies were performed by fortifying fuel samples with acetaldehyde at various concentrations and the results were in the range 98.7-102%, with a coefficient of variation (CV) from 0.2% to 7.2%. Several fuel samples collected from various gas stations were analyzed and the method was successfully applied to the analysis of acetaldehyde in fuel ethanol samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cell culture of Maytenus ilicifolia were established in order to produce and to quantify the antitumoral and antioxidant quinonemethide triterpenes. In vitro calli were induced from leaf explants of native plants and cultured in semi-solid medium under controlled conditions of humidity, temperature and photoperiod. The quinonemethide triterpenes showed maximum accumulation in the logarithmic phase growth of the cell culture. A rapid, sensitive and reliable reverse-phase HPLC method was used for quantitative determination of the antitumoral and antioxidant quinonemethide triterpenes, 22β-hydroxymaytenin and maytenin in callus of Maytenus ilicifolia. Well resolved peaks with good detection response and linearity in the range 1.0 - 100 μg/mL were obtained. This quantitative work was performed by an external standard method.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Eremanthus seidelii MacLeish & Schumacher has a restricted occurrence to the Brazilian cerrado surrounding the Furnas (MG) reservoir, in environments that have been seriously damaged by human activity. The present phytochemical investigation reveals that the sesquiterpene lactones (SL) 4β,5-dihydro-2′,3′-dihydroxy-15-desoxy-goyazensolide (1) and 4β,5-dihydro-1′,2′-epoxy-eremantholide-C (2) are the major secondary metabolites in E. seidelii leaves, and an HPLC method was developed for their quantitative analysis. HPLC analysis showed no significant seasonal variation in the concentrations of both SL. No qualitative differences were found in the SL patterns of all individuals sampled. However, there is a different SL quantitative pattern among the plants analyzed, pointing to the existence of three quantitative chemotypes of this species, with differences possibly originating from the activity of the enzymes that cyclize the goyazensolide type SL (1) to a eremantholide type SL (2). ©2005 Sociedade Brasileira de Química.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Glycomacropeptide is a glycosilated fraction of bovine kappa-casein that remains soluble when milk is clotted by rennin. Determinations of milk sialic acid content are useful because its concentration reflects the amount of free GMP of milk. In normal milk these amounts are very low, 12 to 16 times lower than in sweet whey. Therefore, its determination may be applied to verify possible frauds with whey addictions, since it works as a fingerprint. With the description of a new spectrophotometric method for determination of free GMP (ANSM) occurred a simplification of procedures, being faster than others (HPLC method), without loss of accuracy. However, due to variations of glycosilation in kappa-casein between animals, during the lactation period, due to mastitis and yet due to proteolysis on milk, it was necessary to know these variations to interpret correctly the analytical results. It was analyzed 1,703 samples of producer's raw milk and 1,189 samples of processed milk (HTST and UHT). The results showed that normal milk from herd (producer's milk) have only small amounts of free GMP, with A470nm = 0.232±0.088 or 3.89±1.25 mg of sialic acid/L. The upper limit of this distribution was A = 0.496; thus every bigger value may represent a problem, being outside of normal distribution.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Since the beginning of propolis research, several groups have studied its antibacterial, antifungal, and antiviral properties. However, most of these studies have only employed propolis ethanolic extract (PEE) leading to little knowledge about the biological activities of propolis water extract (PWE). Based on this, in a previous study, we demonstrated the anti-inflammatory and immunomodulatory activities of PWE. In order to better understand the equilibrium between effectiveness and toxicity, which is essential for a new medicine, the characteristics of PWE were analyzed. We developed and validated an RP-HPLC method to chemically characterize PWE and PEE and evaluated the in vitro antioxidant/antimicrobial activity for both extracts and the safety of PWE via determining genotoxic potential using in vitro and in vivo mammalian micronucleus assays. We have concluded that the proposed analytical methodology was reliable, and both extracts showed similar chemical composition. The extracts presented antioxidant and antimicrobial effects, while PWE demonstrated higher antioxidant activity and more efficacious for the most of the microorganisms tested than PEE. Finally, PWE was shown to be safe using micronucleus assays. © 2013 Bruno Alves Rocha et al.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive, precise, and specific high-performance liquid chromatographic (HPLC) method was developed for the assay of gatifloxacin (GATX) in raw material and tablets. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was carried out by reversed-phase chromatography on a C18 absorbosphere column (250 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of acetic acid 50/o--acetonitrile-methanol (70 + 15 + 15, v/v/v) pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 287 nm. The calibration graph for GATX was linear from 4.0 to 14.0 mu g/mL. The interday and intraday precisions (relative standard deviation) were less than 1.05%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of 1% acetic acid-acetonitrile-methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Assessing CYP2E1 phenotype in vivo may be important to predict individual susceptibility to those chemicals, including benzene, which are metabolically activated by this isoenzyme. Chlorzoxazone (CHZ), a specific CYP2E1 substrate, is readily hydroxylated to 6-OH-chlorzoxazone (6-OH-CHZ) by liver CYP2E1 and the metabolic ratio 6-OH-CHZ/CHZ in serum (MR) is a specific and sensitive biomarker of CYP2E1 activity in vivo in humans. We used this MR as a potential biomarker of effect in benzene-treated rats and, also, in humans occupationally exposed to low levels of benzene. Male Sprague-Dawley rats (375-400 g b.w.) were treated i.p. for 3 days with either a 0.5 ml solution of benzene (5 mmol/kg b.w.) in corn oil, or 0.5 ml corn oil alone. Twenty-four hours after the last injection, a polyethylene glycol (PEG) solution of CHZ (20 mg/kg b.w.) was injected i.p. in both treated and control animals. After 2, 5.10,15, 20,30,45, 60, 90, 120, 180, and 240 min from injection, 0.2 ml blood was taken from the tip tail and stored at -20 degrees C until analysis. A modified reverse phase HPLC method using a 5 mu m Ultrasphere C18 column equipped with a direct-connection ODS guard column, was used to measure CHZ and its metabolite 6-OH-CHZ in serum. No statistically significant difference in the MR was observed, at any sampling time, between benzene-treated and control rats. The concentration-versus-time area under the curve (AUC), however, was lower (p < 0.05, Mann-Whitney test), whereas the systemic clearance was higher (p < 0.05) in treated than in control rats. Eleven petrochemical workers occupationally exposed to low levels of airborne benzene (mean +/- SD, 25.0 +/- 24.4 mu g/m(3)) and 13 non-exposed controls from the same factory (mean +/- SD, 6.7 +/- 4.0 mu g/m(3)) signed an informed consent form and were administered 500 mg CHZ p.o. Two hours later a venous blood sample was taken for CHZ and 6-OH-CHZ measurements. Despite exposed subjects showed significantly higher levels of t,t-MA and S-PMA, two biomarkers of exposure to benzene, than non-exposed workers, no difference in the MR mean values +/- SD was found between exposed (0.59 +/- 0.29) and non-exposed (0.57 +/- 0.23) subjects. So, benzene was found to modify CHZ disposition, but not CYP2E1 phenotype in benzene-treated rats, nor in workers exposed to benzene, probably due to the levels of exposure being too low. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A high performance liquid chromatography (HPLC) method for extraction and determination of pesticides from raw milk was developed. The method involves direct injection of raw milk samples on a bovine serum albumin-dimethyl-octyl-silica gel (BSA-Si-Cs) column. The mobile phase 0.05 mol.L-1 phosphate buffer pH6.0 in acetonitrile (70:30 v/v) was employed for extraction and separation of bendiocarb, methylparathion, pentachlorophenol, and methomyl pesticides. The method shows good results of recovery in the pesticides studied, higher than 99.6%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The isolation of polyphenolic compounds from an infusion of the Brazilian plant Davilla elliptica (Dilleniaceae), used as tea by virtue of its digestive properties, is described. An improved preparative HPLC method was used in order to isolate pure polyphenols from the complex mixture. Liquid-liquid extraction and solid-phase extraction were employed to minimise the interference of polymeric compounds and to provide an enriched fraction of the compounds of interest. The identification of the isolated compounds was performed using analytical HPLC as well as direct injection electrospray ionisation ion trap tandem mass spectrometry (ESI-IT-MS/MS). The high flavonoid content suggests that D. elliptica may be a promising source of compounds to produce natural phytomedicines. Copyright (C) 2007 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two high-performance liquid chromatographic methods for determination of residual monomer in dental acrylic resins are described. Monomers were detected by their UV absorbance at 230 nm, on a Nucleosil((R)) C-18 (5 mu m particle size, 100 angstrom pore size, 15 x 0.46 cm i.d.) column. The separation was performed using acetonitrile-water (55:45 v/v) containing 0.01% triethylamine (TEA) for methyl methacrylate and butyl methacrylate, and acetonitrile-water (60:40 v/v) containing 0.01% TEA for isobutyl methacrylate and 1,6-hexanediol dimethacrylate as mobile phases, at a flow rate of 0.8 mL/min. Good linear relationships were obtained in the concentration range 5.0-80.0 mu g/mL for methyl methacrylate, 10.0-160.0 mu g/mL for butyl methacrylate, 50.0-500.0 mu g/mL for isobutyl methacrylate and 2.5-180.0 mu g/mL for 1,6-hexanediol dimethacrylate. Adequate assay for intra- and inter-day precision and accuracy was observed during the validation process. An extraction procedure to remove residual monomer from the acrylic resins was also established. Residual monomer was obtained from broken specimens of acrylic disks using methanol as extraction solvent for 2 h in an ice-bath. The developed methods and the extraction procedure were applied to dental acrylic resins, tested with or without post-polymerization treatments, and proved to be accurate and precise for the determination of residual monomer content of the materials evaluated. Copyright (c) 2005 John Wiley & Sons, Ltd.