86 resultados para Flat plate


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the investigation of an abrasive process for finishing flat workpieces, based on the combination of important grinding and lapping characteristics. Instead of loose abrasive grains between the workpiece and the lapping plate, a resinoid grinding wheel of hot-pressed silicon carbide is placed on the plate of a device resembling a lapping machine. The resin bond grinding wheel is dressed with a single-point diamond. In addition to keeping the plate flat, dressing also plays the role of interfering in the behavior of the process by varying the overlap factor (Ud). It was found that the studied process simplify the set-up and can be controlled more easily than in lapping, whose is a painstaking process. The surface roughness and flatness deviation proved comparable to those of lapping, or even finer than it, with the additional advantage of a less contaminated workpiece surface with a shiny appearance. The process was also monitored by acoustic emission (AE), which indicates to be a promissing and suitable technique for use in this process. Copyright © 2008 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pyrophosphatase activity of rat osseous plate alkaline phosphatase was studied at different concentrations of calcium and magnesium ions. with the aim of characterizing the modulation of enzyme activity by these metals. In the absence of metal ions, the enzyme hydrolysed pyrophosphate following Michaelian kinetics with a specific activity of 36.7 U/mg and K-0.5 = 88 mu M. In the presence of low concentrations (0.1 mM) of magnesium (or calcium) ions, the enzyme also exhibited Michaclian kinetics for the hydrolysis of pyrophosphate, but a significant increase in specific activity (123 U/mg) was observed. K-m values remained almost unchanged. Quite different behavior occurred in the presence of 2 mM magnesium (or calcium) ions. In addition to low-affinity sites (K-0.5 = 40 and 90 mu M, for magnesium and calcium, respectively), high-affinity sites were also observed with K-0.5 values 100-fold lower. The high-affinity sites observed in the presence of calcium ions represented about 10% of those observed for magnesium ions. This was correlated with the fact that only magnesium ions triggered conformational changes yielding a fully active enzyme. These results suggested that the enzyme could hydrolyse pyrophosphate, even at physiological concentrations (4 mu M), since magnesium concentrations are high enough to trigger conformational changes increasing the enzyme activity. A model, suggesting the involvement of magnesium ions in the hydrolysis of pyrophosphate by rat osseous plate alkaline phosphatase is proposed. (C) 1998 Published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purified membrane-bound alkaline phosphatase from rat osseous plate hydrolyzed pyrophosphate in the presence of magnesium ions, with a specific activity of 92.7 U/mg. Optimal apparent pH for pyrophosphatase activity was 8.0 and it remained unchanged on increasing the pyrophosphate concentration. In the absence of magnesium ions the enzyme had a K-m = 88 mu M and V = 36.7 U/mg for pyrophosphate and no inhibition by excess substrate was observed. Pyrophosphatase activity was rapidly destroyed at temperatures above 40 degrees C, but magnesium ions apparently protected the enzyme against danaturation. Sodium metavanadate (Ki = 1.0 mM) was a competitive inhibitor of pyrophosphatase activity, while levamisole (Ki = 8.2 mM) and theophylline (Ki = 7.4 mM) were uncompetitive inhibitors. Magnesium ions (K-0.5 = 1.7 mu M) stimulated pyrophosphatase activity, while cobalt (Ki = 48.5 mu M) and zinc (Ki = 22.0 mu M) ions were non-competitive inhibitors. Manganese and calcium ions had no effect on pyrophosphatase activity. The M-w of the pyrophosphatase: protein was 130 kDa by gel filtration, but a value of 65 kDa was obtained by dissociative gel electrophoresis, suggesting that it was a dimer of apparently identical subunits. These results suggested that pyrophosphatase activity stems from the membrane-bound osseous plate alkaline phosphatase and not from a different protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment with phosphatidylinositol-specific phospholipase C of rat osseous plate membranes released up to 90-95% of alkaline phosphatase, but a specific ATPase activity (optimum pH = 7.5) remained bound to the membrane. The hydrolysis of ATP by this ATPase was negligible in the absence of magnesium or calcium ions. However, at millimolar concentrations of magnesium and calcium ions, the membrane-specific ATPase activity increased to about 560-600 U/mg, exhibiting two classes of ATP-hydrolysing sites, and site-site interactions. GTP, UTP, ITP, and CTP were also hydrolyzed by the membrane-specific ATPase. Oligomycin, ouabain, bafilomycin A(1), thapsigargin, omeprazole, ethacrynic acid and EDTA slightly affected membrane-specific ATPase activity while vanadate produced a 18% inhibition. The membrane-specific ATPase activity was insensitive to theophylline, but was inhibited 40% by levamisole. These data suggested that the membrane-specific ATPase activity present in osseous plate membranes, and alkaline phosphatase, were different proteins. (C) 1998 Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teve-se o objetivo de verificar a possível seleção de sementes de milho - arredondadas e achatadas - no processo de semeadura com disco perfurado horizontal, bem como as conseqüências na distribuição longitudinal. Os registros dos dados deram-se pela avaliação visual de duas pessoas, com contador manual, no final da esteira carpetada em movimento de 1,54 m s-1, com 4,60 m de perspectiva para avaliação. Assim, um sensor registrava o número de orifícios do disco horizontal que devia passar pelo tubo condutor, e os espaçamentos falhos e múltiplos eram computados por pessoas diferentes. Os espaçamentos aceitáveis foram obtidos pela subtração dos espaçamentos falhos e múltiplos do total contabilizado. A medição do comprimento e espessura das sementes foi realizada com auxílio de paquímetro. Não houve alterações significativas nas variáveis estudadas, até a passagem de 55 mil orifícios do disco horizontal pelo tubo condutor; portanto, não houve seleção de sementes de milho durante a simulação do processo de semeadura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a boundary element formulation for the analysis of building floor slabs, without beams, in which columns are coupled with the plate. An alternative formulation of boundary element method is presented, which considers three nodal displacements values (w, partial derivativew/partial derivativen and partial derivativew/partial derivatives) for the nodes at the boundary of the plate. In this formulation three boundary equations are written for all nodes at the boundary and in the domain of the plate. As the nodes of the column-plate connections are also represented by three nodal values, all these structural elements can be easily coupled. It is supposed that the cross-sections of the columns remain flat after the deflection and consequently the assumption of linear variation of the stress in the plate-column contact surface is also valid. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar a influência do Laser Terapêutico de Baixa Potência sobre a placa de crescimento de ratos. MÉTODOS: Trinta ratos Wistar machos com 40 dias de idade foram divididos em dois grupos, G1 e G2. O grupo G1 foi submetido à irradiação com laser GaAlAs 830 nm, potência de saída de 40 mW, e densidade de energia de 10 J/cm2. A irradiação foi aplicada diariamente por um período máximo de 21 dias. O mesmo procedimento foi realizado no grupo G2, com a probe desativada. Cinco animais em cada grupo foram sacrificados nos dias 7, 14 e 21 e submetidas à análise histomorfométrica. RESULTADOS: em ambos os grupos, o disco fisário esteve radiograficamente visível em todos os momentos nas incidências craniocaudal e médio-lateral. No 21º dia a porcentagem de comprimento longitudinal do fêmur foi maior em G1 que em G2 em relação ao valor basal, e o número de condrócitos da zona hipertrófica foi maior em G1 que em G2. A zona de cartilagem calcificada estava maior em G1 em relação a G2 em todos os momentos de avaliação. A angiogênese foi maior em G1 que em G2 nos 14º e 21º dias. CONCLUSÃO: A terapia com laser terapêutico de baixa potência influenciou negativamente o disco fisário distal do fêmur de ratos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)