60 resultados para Digital-to-analog converters


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The architecture of proposed input stage converter is composed by five interleaved boost rectifiers operating in discontinuous conduction mode. Furthermore, due to the power lines characteristics, the proposed input power structure can act as AC to DC or as DC to DC converter providing a proper DC output voltage range required to the DC bus. When operation is AC to DC, the converter is capable to provide high power factor with reduced harmonic distortion for the input current, complying with the restrictions imposed by IEC 61000-3-4 standard. Finally, the main experimental results are presented in order to verify the feasibility of the proposed converter, demonstrating the benefits and the possibility for AC feeding system for trolleybus type vehicle. © 2010 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper a new algorithmic of Analog-to-Digital Converter is presented. This new topology use the current-mode technique that allows a large dynamic range and can be implemented in digital CMOS process. The ADC proposed is very small and can handle high sampling rates. Simulation results using a 1.2um CMOS process show that an 8-b ADC can support a sampling rate of 50MHz.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper provides an insight to the trade-off between settling time and power consumption in regulated current mirrors as building parts in micropower current-switching D/A converters. The regulation-loop frequency characteristic is obtained and difficulties to impose a dominant-pole condition to the resulting 2nd-order system are evaluated. Raising pole frequencies in micropower circuits, while meeting consumption requirements, is basically limited by parasitic capacitances. For such cases, an alternative is to impose a twin-pole condition in which design constraints are somewhat relieved and settling slightly improved. Relationships between pole frequencies, transistor geometry and bias are established and design guidelines for regulated current mirrors founded. By placing loop-transistors in either weak or strong inversion, small (W/L) ratios are allowed and stray capacitances reduced. Simulated waveforms suggest a good agreement with theory. The proposed approach applied to the design of a micropower current-mode D/A converter improves both simulated and experimental settling performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work proposes a methodology to generalize the Y-connections for 12- and 18-pulse autotransformers. A single mathematical expression, obtained through simple trigonometric operations, represents all the connections. The proposed methodology allows choosing any ratio between the input and the output voltages. The converters can operate either as step-up or as step-down voltage. To simplify the design of the windings, graphics are generated to calculate the turn-ratio and the polarity of each secondary winding, with respect to the primary winding. A design example, followed by digital simulations, illustrates the presented steps. Experimental results of two prototypes (12 and 18 pulses) are presented. The results also show that high power factor is an inherent characteristic of multi-pulse converters, without any active or passive power factor pre-regulators needs. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An accurate switched-current (SI) memory cell and suitable for low-voltage low-power (LVLP) applications is proposed. Information is memorized as the gate-voltage of the input transistor, in a tunable gain-boosting triode-transconductor. Additionally, four-quadrant multiplication between the input voltage to the transconductor regulation-amplifier (X-operand) and the stored voltage (Y-operand) is provided. A simplified 2 x 2-memory array was prototyped according to a standard 0.8 mum n-well CMOS process and 1.8-V supply. Measured current-reproduction error is less than 0.26% for 0.25 muA less than or equal to I-SAMPLE less than or equal to 0.75 muA. Standby consumption is 6.75 muW per cell @I-SAMPLE = 0.75 muA. At room temperature, leakage-rate is 1.56 nA/ms. Four-quadrant multiplier (4QM) full-scale operands are 2x(max) = 320 mV(pp) and 2y(max). = 448 mV(pp), yielding a maximum output swing of 0.9 muA(pp). 4QM worst-case nonlinearity is 7.9%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work proposes a methodology to generalize the A-connections for 12 and 18-pulse autotransformers. A single mathematical expression, obtained through simple trigonometric operations, represents all the connections. The proposed methodology allows choosing any ratio between the input and the output voltages. The converters can operate either as step-up or as step-down voltage. To simplify the design of the windings, graphics are generated to calculate the turn-ratio and the polarity of each secondary winding, with respect to the primary winding. A design example, followed by digital simulations, and experimental results illustrate the presented steps. The results also show that high power factor is an inherent characteristic of multi-pulse converters, without any active or passive power factor pre-regulators needs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The identification of ground control on photographs or images is usually carried out by a human operator, who uses his natural skills to make interpretations. In Digital Photogrammetry, which uses techniques of digital image processing extraction of ground control can be automated by using an approach based on relational matching and a heuristic that uses the analytical relation between straight features of object space and its homologous in the image space. A build-in self-diagnosis is also used in this method. It is based on implementation of data snooping statistic test in the process of spatial resection using the Iterated Extended Kalman Filtering (IEKF). The aim of this paper is to present the basic principles of the proposed approach and results based on real data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A linearly tunable low-voltage CMOS transconductor featuring a new adaptative-bias mechanism that considerably improves the stability of the processed-signal common,mode voltage over the tuning range, critical for very-low voltage applications, is introduced. It embeds a feedback loop that holds input devices on triode region while boosting the output resistance. Analysis of the integrator frequency response gives an insight into the location of secondary poles and zeros as function of design parameters. A third-order low-pass Cauer filter employing the proposed transconductor was designed and integrated on a 0.8-mum n-well CMOS standard process. For a 1.8-V supply, filter characterization revealed f(p) = 0.93 MHz, f(s) = 1.82 MHz, A(min) = 44.08, dB, and A(max) = 0.64 dB at nominal tuning. Mined by a de voltage V-TUNE, the filter bandwidth was linearly adjusted at a rate of 11.48 kHz/mV over nearly one frequency decade. A maximum 13-mV deviation on the common-mode voltage at the filter output was measured over the interval 25 mV less than or equal to V-TUNE less than or equal to 200 mV. For V-out = 300 mV(pp) and V-TUNE = 100 mV, THD was -55.4 dB. Noise spectral density was 0.84 muV/Hz(1/2) @1 kHz and S/N = 41 dB @ V-out = 300 mV(pp) and 1-MHz bandwidth. Idle power consumption was 1.73 mW @V-TUNE = 100 mV. A tradeoff between dynamic range, bandwidth, power consumption, and chip area has then been achieved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To evaluate the oral features in individuals with oral-facial-digital syndrome type 1 (OFD 1), previously diagnosed by the Genetic Sector of the Hospital of Rehabilitation of Craniofacial Anomalies of the University of São Paulo (HRAC-USP).Design: Twelve patients with OFD 1 were examined clinically and radiographically; their medical files were also evaluated.Results: Associated oral malformations were observed in all patients (100%). The most frequent findings were tongue hamartomas, multiple buccal frena, asymmetric lips, asymmetric tongue, and bilateral maxillary gingival swelling. Interestingly, atrophy of the maxillary midline frenum was also observed in all the individuals examined.Conclusions: Several extra and intraoral alterations were observed in patients with OFD 1. The authors suggest the inclusion of atrophy of the maxillary midline frenum as a commonly found characteristic of OFD 1.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work aims at finding out the threshold to burning in surface grinding process. Acoustic emission and electric power signals are acquired from an analog-digital converter and processed through algorithms in order to generate a control signal to inform the operator or interrupt the process in the case of burning occurrence. The thresholds that dictate the situation of burn and non-burn were studied as well as a comparison between the two parameters was carried out. In the experimental work one type of steel (ABNT-1045 annealed) and one type of grinding wheel referred to as TARGA model 3TG80.3-NV were employed. Copyright © 2005 by ABCM.