295 resultados para Cleaning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and fast procedure is proposed for cleaning autosampler cups using acid-vapor steam-cleaning with a miniaturized assembly in a microwave-heated sealed Teflon vessel. A glass cactus-shaped holder was made to support six polyethylene autosampler cups (volume, 2.0 mt) inside a 100 mt microwave vessel. Regent-grade nitric acid was added to the vessels, and the system was heated in a microwave oven for 5 min at 300 W. Chromium was determined by graphite-furnace atomic-absorption spectrophotometry. The blank values were lower with cleaned cups compared to untreated cups (i.e., as received from supplier). The quantification limits, estimated from detection limits established with Milli-Q water, were 0.66 and 0.95 mu g Cr L-1 for cleaned and untreated auto-sampler cups, respectively. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate the spread of Salmonella Enteritidis to different cutting boards (wood, triclosan-treated plastic, glass, and stainless steel) from contaminated poultry skin (5 log CFU/g) and then to tomatoes and to analyze the effect of different protocols used to clean these surfaces to control contamination. The following procedures were simulated: (1) no cleaning after handling contaminated poultry skin; (2) rinsing in running water; (3) cleaning with dish soap and mechanical scrubbing; and (4) cleaning with dish soap and mechanical scrubbing, followed by disinfection with hypochlorite. The pathogen was recovered from all surfaces following procedure 1, with counts ranging from 1.90 to 2.80 log, as well as from the tomatoes handled on it. Reduced numbers of S. Enteritidis were recovered using the other procedures, both from the surfaces and from the tomatoes. Counts were undetectable after procedure 4. From all surfaces evaluated, wood was the most difficult to clean, and stainless steel was the easiest. The use of hypochlorite as a disinfecting agent helped to reduce cross-contamination. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A selection of commercially available disinfectants, sanitizers and water sanitizers based on iodophor, quaternary ammonium compounds (QACs) and phenolic compounds were tested for their activity against a phage type 4 strain of Salmonella serotype Enteritidis in the presence of a variety of organic materials. In general the phenolic preparations were the most effective followed by the QACs and the iodophors. They were all inactivated to different degrees by chick fluff, chicken faeces, feed and wood shavings. The inactivation was greatest when Salmonella organisms were pre-dried in feed. Under these conditions formaldehyde and glutaraldehyde were still active. There was some evidence that induced resistance to stress conditions including culture at 42°C and anaerobic culture increased resistance to one of the water sanitizers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical microscopy and morphometric analysis were used in this study to evaluate, in vitro, the cleaning of the apical region in root canals with mild or moderate curvatures subjected to biomechanical preparation with a rotary system, as well as to assess the amount of extruded material to the periapical area. Lateral incisors (n = 32), 16 with curvature angles smaller or equal to 10° (GI) and 16 between 11° and 25° angles (GII) were submitted to Hero 642 rotary instrumentation with different surgical diameters: (A) 30.02 and (B) 45.02. Irrigation was performed at each change of instrument with 5 mL of ultrapure Milli-Q water and the extruded material through the apical foramen was collected. Root cross-sections were subjected to histological analysis by optical microscopy (×40) and the images were evaluated morphometrically using the Image Tool software. Quantification of the extruded material was performed by weighing after liquid evaporation. ANOVA showed no statistically significant differences (p>0.05) among the groups with respect to the procedures used to clean the apical region. Considering the amount of extruded material, the Tukey's HSD showed that canals with mild curvature prepared with the 45.02 surgical diameter showed significantly higher values (p<0.05) that those of the other groups, which were similar between themselves (p>0.05). In conclusion, the effect of cleaning the apical region did not differ in the groups, considering root curvature and the surgical diameter of instruments used for apical preparation. The amount of extruded material was greater in canals with mild curvature that were prepared with the 45.02 surgical instrument diameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the influence of irrigation needle gauge and design, and the final root canal diameter on the apical cleaning efficacy. Twelve human mandibular incisors were used. At different stages of root canal widening (sizes 20, 30 and 40 K-files), root canals were filled with radiopaque contrast medium. Four different needles were evaluated: 23G with side opening, 22G with apical opening, 30G with side opening and 30G with apical opening. Irrigation was carried out with 2 mL distilled water. The same tooth was radiographed with a digital system several times to assess the four types of needle in those three stages of canal widening. Pre-irrigation (canals filled with contrast) and post-irrigation (canals with remaining contrast) images were submitted to digital subtraction using the Adobe Photoshop CS4 program. Pre-irrigation (filled with contrast) and subtracted (cleaned by irrigation) areas were outlined by a trained and blinded operator using the Image Tool 3.0 software. Their ratio was calculated to express the percentage of apical cleaning in each stage of canal widening (sizes 20, 30 and 40 K-files) with each of the four needles. Data obtained were subjected to one-way ANOVA and Tukey's tests. The 30G needles with side and apical opening promoted better apical cleaning at all stages of root canal widening (p<0.05). In conclusion, smaller diameter needles were more efficacious in cleaning the apical third of the root canals, regardless of their design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Computação - IBILCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Researches concerning cooling-lubrication optimization in grinding have been conducted to contribute to a more sustainable process. An alternative to flood coolant is minimum quantity lubrication (MQL), which spray oil droplets in a compressed air jet. However, problems related to wheel cleaning were reported, due to wheel loading by a mixture of chips and oil, resulting in worsening of surface quality. This work aims to evaluate the viability of Teflon and aluminum oxide for wheel cleaning, compared to MQL without cleaning and MQL with cleaning by compressed air, through the following output variables: surface roughness, roundness, wheel wear, grinding power and acoustic emission. Vickers microhardness measurements and optical microscopy were also carried out. The results showed that both materials were efficient in cleaning the wheel, compared to MQL without cleaning, but not as satisfactory as compressed air. Much work is to be done in order to select the right material for wheel cleaning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conveyor belts are widely used in food handling areas, especially in poultry processing plants. Because they are in direct contact with food and it is a requirement of the Brazilian health authority, conveyor belts are required to be continuously cleaned with hot water under pressure. The use of water in this procedure has been questioned based on the hypothesis that water may further disseminate microorganisms but not effectively reduce the organic material on the surface. Moreover, reducing the use of water in processing may contribute to a reduction in costs and emission of effluents. However, no consistent evidence in support of removing water during conveyor belt cleaning has been reported. Therefore, the objective of the present study was to compare the bacterial counts on conveyor belts that were or were not continuously cleaned with hot water under pressure. Superficial samples from conveyor belts (cleaned or not cleaned) were collected at three different times during operation (T1, after the preoperational cleaning [5 a.m.]; T2, after the first work shift [4 p.m.]; and T3, after the second work shift [1:30 a.m.]) in a poultry meat processing facility, and the samples were subjected to mesophilic and enterobacterial counts. For Enterobacteriaceae, no significant differences were observed between the conveyor belts, independent of the time of sampling or the cleaning process. No significant differences were observed between the counts of mesophilic bacteria at the distinct times of sampling on the conveyor belt that had not been subjected to continuous cleaning with water at 45 degrees C. When comparing similar periods of sampling, no significant differences were observed between the mesophilic counts obtained from the conveyor belts that were or were not subjected to continuous cleaning with water at 45 degrees C. Continuous cleaning with water did not significantly reduce microorganism counts, suggesting the possibility of discarding this procedure in chicken processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the effect of different etching durations of feldspathic ceramic with hydrofluoric acid (HF) and ultrasonic cleaning of the etched ceramic surface on the microtensile bond strength stability of resin to a feldspathic ceramic. The research hypotheses investigated were: (1) different etching times would not affect the adhesion resistance and (2) ultrasonic cleaning would improve the adhesion. Ceramic blocks (6 x 6 x 5 mm) (N = 48) were obtained. The cementations surfaces were duplicated in resin composite. The six study groups (n = 8) were: G1Etching with 10% aqueous HF (30 s) + silane; G 210% HF (1 min) + silane; G3-10% HF (2 min) + silane; G4-10% HF (30 s) + ultrasonic cleaning (4 min) in distilled water + silane; G5-10% HF (1 min) + ultrasonic cleaning + silane; G6-10% HF (2 min) ultrasonic cleaning + silane. The cemented blocks were sectioned into microbars for the microtensile test. The etching duration did not create significant difference among the groups (p = .156) but significant influence of ultrasonic cleaning was observed (p = .001) (Two-way ANOVA and Tukey's test, p > 0.05). All the groups after ultrasonic cleaning presented higher bond strength (19.38-20.08 MPa) when compared with the groups without ultrasonic cleaning (16.2117.75 MPa). The bond strength between feldspathic ceramic and resin cement was not affected by different etching durations using HF. Ultrasonic cleaning increased the bond strength between ceramic surface and resin cement, regardless of the etching duration.