502 resultados para root canal irrigants


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim To compare the ex vivo antibacterial effectiveness of the Endox Plus system and sodium hypochlorite (NaOCl) in combination with BioPure MTAD (Tulsa Dental, Tulsa, OK, USA) or with EDTA in Enterococcus faecalis-contaminated root canals.Methodology After initial preparation, the root canals of 70 single-rooted human teeth were inoculated with E. faecalis (ATCC 29212) and incubated for 21 days. Specimens were divided into five groups: Endox Plus/saline; 2.5% NaOCl/MTAD; 2.5% NaOCl/EDTA; saline (positive control); negative control (root canals not prepared, nor irrigated). Samples were collected using paper points. Microbiological analysis evaluated the number of CFUs. Data were analysed by anova and Tukey tests at 0.05 significance.Results All specimens had bacterial growth after the incubation period, with similar CFU per mL counts (P > 0.05). After chemo-mechanical preparation, the number of bacteria in all groups reduced, except for the negative control. No significant differences were observed between 2.5% NaOCl/MTAD and 2.5% NaOCl/EDTA, but these groups had lower CFU counts than the other groups (P < 0.05). In the final samples, an increase in the bacterial counts was observed for Endox Plus/saline, 2.5% NaOCl/MTAD, 2.5% NaOCl/EDTA and saline (P < 0.05) with no significant differences between these groups.Conclusions This ex vivo study revealed that the Endox Plus system was associated with a reduced antibacterial effectiveness compared with conventional irrigation using 2.5% NaOCl/MTAD and 2.5% NaOCl/EDTA. All irrigation procedures allowed recovery of bacteria 7 days after treatment, demonstrating persistence of contamination within the root canal system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin. Material and Methods: Forty extracted single-rooted human teeth were examined and the coronal and middle thirds of the canals were prepared with a 1.50 mm post drill (FibreKor Post System, Pentron). The teeth were allocated in two experimental groups, irrigated with 2.5% NaOCl+17% EDTA or saline solution (control group) and instrumented using Race rotary files (FKG) to a size #40 at the working length. Then, the groups were divided into four subgroups and filled with Epiphany sealer (Group 1), EndoREZ (Group 2), AH26 (Group 3) and Grossman's Sealer (Group 4). After 2 weeks of storage in 100% humidity at 37 degrees C, all teeth were sectioned transversally into 2-mm-thick discs. Push-out tests were performed at a cross-head speed of 1 mm/min using a universal testing machine. The maximum load at failure was recorded and expressed in MPa. Results: Means (+/- SD) in root canals irrigated with 2.5% NaOCl and 17% EDTA were: G1 (21.6 +/- 6.0), G2 (15.2 +/- 3.7), G3 (14.6 +/- 4.5) and G4 (11.7 +/- 4.1). Two-way ANOVA and Tukey's test showed the highest bond strength for the Epiphany's group (p < 0.01) when compared to the other tested sealers. Saline solution decreased the values of bond-strength (p < 0.05) for all sealers. Conclusion: Epiphany sealer presented higher bond strength values to dentin in both irrigating protocols, and the use of 2.5% NaOCl and 17% EDTA increased the bond strength values for all sealers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To report the outcome of the endodontic treatment of a reimplanted central maxillary incisor with open apex after 8 years and 7 months of follow-up.This case report presents the treatment of a right central maxillary incisor of an 8-year old white male patient with history of traumatic avulsion and immediate replantation. The endodontic therapy consisted of periodical changes of calcium hydroxide dressing and a definitive root canal filling with mineral trioxide aggregate (MTA). The treatment was successful without pathologies up to 7 years of follow-up. After the institution of orthodontic treatment a localized and late root resorption was noticed at the last radiographic examination (8 years and 7 months postoperative follow-up). Moreover, the use of MTA promoted a mild crown grey discoloration.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated the presence of residues after removal of calcium hydroxide [Ca(OH)2] associated with different vehicles. Thirty single-rooted teeth were instrumented to a master apical file #25 using 2.5% NaOCl as main irrigant and 17% trisodium EDTA (ethylenediaminetetraacetic acid) as final agent irrigant. Then, the root canals were dressed with Ca(OH)2 associated with silicone oil (Group 1), 2% chlorhexidine gluconate (Group 2), or propylene glycol (Group 3). After coronal sealing, all teeth were kept in a moist environment at room temperature. After 7 days, the teeth were reopened and medicaments were removed using 5 mL of saline solution and instrumentation with master apical file followed by new irrigation with 5 mL of 2.5% NaOCl. Subsequently, teeth were split longitudinally and assessed by scanning electron microscopy. The wall cleanliness of the cervical and apical thirds of the roots were evaluated and scored by three blinded examiners. Statistical analysis was performed using KruskalWallis and Wilcoxon tests at 5% level of significance. All roots had residues of Ca(OH)2 on the canal walls. All experimental groups had similar results (P > 0.05) regardless of the third evaluated. There was significant difference between the apical and cervical thirds only in Group 3 (P < 0.05). Association of different vehicles to Ca(OH)2 does not influence the persistence of residues on the root canal walls. Microsc. Res. Tech. 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the ability of Resilon (Resilon Research, LLC, North Branford, CT) and 2 types of gutta-percha to fill simulated lateral canals when using the Obtura II system (Model 823-700; Obtura Spartan, Fenton, MO). Methods: Forty-five human single-rooted teeth were selected and subjected to root canal preparation. After that, simulated lateral canals were made at 2, 5, and 8 mm from the working length (WL). The specimens were divided into 3 groups (n = 15) according to the filling material used: Obtura Flow 150 gutta-percha (Obtura flow), Odous Endo Flow gutta-percha (Odous; Odous de Deus Ind e Corn. Ltda Belo Horizonte, MG, Brazil), and Resilon pellets (Resilon). Root canals were filled using the Obtura II system with the tip inserted to 3 mm from the WL. No sealer was used for root canal obturation. Specimens were subjected to a tooth decalcification and clearing method, and filling of the lateral canals was analyzed by digital radiography and photographs. The measurement of lateral canal filling was done using Image Tool software (UTHSCSA Image Tool for Windows version 3.0, San Antonio, TX). Data were statistically analyzed with the Kruskal-Wallis test at 5% significance. Results: All materials showed an ability to penetrate into the simulated lateral canals, with a minimum percentage of 73% in all thirds of the root canal. Conclusions: It was concluded that gutta-percha and Resilon are solid core materials with a lateral canal filling ability when used with the Obtura II system. (J Endod 2012;38:676-679)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Epiphany (TM) Sealer is a new dual-curing resin-based sealer and has been introduced as an alternative to gutta-percha and traditional root canal sealers. The canal filling is claimed to create a seal with the dentinal tubules within the root canal system producing a 'monoblock' effect between the sealer and dentinal tubules. Therefore, considering the possibility to incorporate the others adhesive systems, it is important to study the bond strength of the resulting cement. Forty-eight root mandibular canines were sectioned 8-mm below CEJ. The dentine discs were prepared using a tapered diamond bur and irrigated with 1% NaOCl and 17% EDTA. Previous the application Epiphany (TM) Sealer, the Epiphany (TM) Primer, AdheSE, and One Up Bond F were applied to the root canal walls. The LED and QTH (Quartz Tungsten Halogen) were used to photo-activation during 45 s with power density of 400 and 720 mW/cm(2), respectively. The specimens were performed on a universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The force was recorded and the debonding values were used to calculate Push-out bond strength. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed significant statistical differences (P < 0.05) to Epiphany (TM) Sealer/Epiphany (TM) Primer/QTH and EpiphanyTM Sealer/AdheSE/QTH, which had the highest mean values of bond strength. The efficiency of resin-based filling materials are dependent the type of light curing unit used including the power density, the polymerization characteristics of these resin-based filling materials, depending on the primer/adhesive used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to evaluate the apical sealing of dentinal tubules after root-end surface cutting by using Er:YAG and Nd:YAG lasers. After root-canal instrumentation and filling, apices of 50 extracted maxillary canine human teeth were resected by Er: YAG with 400 mJ, 10 Hz, for 30 sec. The samples were randomly assigned to five groups (n = 10): (GI) treated without root-end cavity, but with Nd: YAG (1.0W, 10 Hz, 20 sec) for dentinal tubules sealing; (GII) treated with root-end cavity without the use of Nd: YAG; (GIII) treated with root-end cavity and Nd: YAG application; (GIV) treated with root-end cavity made by Er: YAG with no focus and without Nd: YAG application; and (GV) treated without root-end cavity and without Nd: YAG application. The root-end cavities were performed by using Er: YAG at 300 mJ, 10 Hz, for 20 sec. Subsequently, all teeth were waterproofed and immersed in 2% methylene blue for 48 h in a vacuum environment. The samples were longitudinally sectioned, and microleakage was measured. ANOVA and the Fisher LSD test showed that GIV was less susceptible to microleakage than were the other groups (p < 0.05). Interestingly, the use of the Er: YAG with no focus showed superior dentinal tubule sealing in comparison with the other groups, even with or without root-end cavity and Nd: YAG application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The success of endodontic treatment depends on the complete elimination of microorganisms from the root canal system, thus the search for new procedures to eliminate them is justified. The aim of this study was to assess bacterial reduction after intracanal irradiation with the Er:YAG laser. The canals of 70 extracted human maxillary canines were prepared up to file #40 using 1% NaOCl, irrigated with 17% EDTA, and then washed with physiological solution activated by ultrasound. The roots were sterilized by autoclaving, inoculated with 10 mu l of a suspension containing 1.5 x 10(8) CFU/ml of Enterococcus faecalis ATCC 29212 and incubated at 37A degrees C for 72 h. The canals were irradiated with the Er:YAG laser using two energy settings: 60 mJ and 15 Hz, and 100 mJ and 10 Hz. The remaining bacteria were counted immediately and 48 h after laser irradiation. The results showed a high bacterial reduction at both time points. With 60 mJ and 15 Hz there was an immediate reduction of 99.73% and the reduction was 77.02% after 48 h, and with 100 mJ and 10 Hz there was an immediate reduction of 99.95% and the reduction was 84.52% after 48 h. Although the best results were observed with 100 mJ of energy, the difference between the two settings was not statistically significant. The count performed 48 h after irradiation showed that E. faecalis were able to survive, and can grow even from small numbers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. Methods: One hundred eighty bovine incisors were selected to assess post retention; after endodontic treatment, the canals were flared with diamonds burs. Post holes were prepared in lengths of 5, 7.5, and 10 mm; the fiber posts were relined with composite resin and luted with RelyX ARC, RelyX Unicem, or RelyX Luting 2. All cements are manufactured by 3M ESPE (St. Paul, MN). Samples were subjected to a pull-out bond strength test in a universal testing machine; the results (N) were submitted to a three-way analysis of variance and the Tukey post hoc test (alpha = 0.05). Results: The improvement of post retention occurred with the increase of the post length luted into the root canal; the relining procedure improved the pull-out bond strength. RelyX Unicem and RelyX ARC showed similar values of retention, both showing higher values than RelyX Luting 2. Conclusion: Post length, the reining procedure, and the cement type are all important factors for improving the retention of fiber posts. (J Endod 2010;36:1543-1546)