505 resultados para distilled spirits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal conductivity, thermal diffusivity, and density of yellow mombin juice were determined at 8.8-49.4 °Brix and at temperature from 0.4 to 77.1 °C. Apparent viscosity was also measured between 7.8 and 30 °Brix and at temperature from 0 to 60 °C. Yellow mombin juice was produced from fruits of two different batches and the concentration process was performed using a roto evaporator or a rising film evaporator, single effect, with recirculation, under vacuum, to obtain concentrated juice. In order to obtain different concentrations, concentrated juice was diluted with distilled water. Multiple regression analysis was performed to fit thermal conductivity, thermal diffusivity and density experimental data obtaining a good fit. Arrhenius and power law relationships were proposed to fit apparent viscosity as a function of temperature and juice concentration at typical shear rates found during processing. The rheological parameters together with experimental values of pressure loss in tube flow were used to calculate friction factors, which were compared to those resulting from theoretical equation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the ultimate tensile strength of a tissue conditioner without nystatin incorporation (GI - control group) and the same tissue conditioner modified by the addition of nystatin in two concentrations: GII - 500,000 International Units (U) and GIII - 1,000,000 U, in which each milligram of the medicament corresponded to 6079 U. Materials and Methods: Dumbbell-shaped specimens (N = 7) with a central cross-sectional area of 33 × 6 × 3 mm were produced for the three experimental groups. After polymerization following manufacturer's instructions, specimens were immersed in distilled water at 37°C for either 24 hours or 7 days and then tested in tension in the MTS 810 at 40 mm/minute. Data were analyzed by two-way ANOVA followed by Tukey's test, at 95% level of confidence. Results: The means (force-grams (gf) ± standard deviation) of the ultimate tensile strength were: GI - 634.29 ± 122.80; GII - 561.92 ± 133.56; and GIII - 547.30 ± 73.47 for 24-hour storage, and GI - 536.68 ± 54.71; GII - 467.50 ± 143.51; and GIII - 500.62 ± 159.76 for 7-day storage. There were no statistically significant differences among the three experimental groups (p > 0.05). The ultimate tensile strength means of all experimental groups after 7 days were significantly lower than those observed after 24 hours (p = 0.04). Conclusions: The results of this study suggest that the addition of nystatin into the tissue conditioner investigated in concentrations below 1,000,000 U did not affect its ultimate tensile strength. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate in vitro three adhesive systems: a total etching single-component system (G1 Prime & Bond 2.1), a self-etching primer (G2 Clearfil SE Bond), and a self-etching adhesive (G3 One Up Bond F), through shear bond strength to enamel of human teeth, evaluating the type of fracture through stereomicroscopy, following the ISO guidance on adhesive testing. Thirty sound premolars were bisected mesiodistally and the buccal and lingual surfaces were embedded in acrylic resin, polished up to 600-grit sandpapers, and randomly assigned to three experimental groups (n = 20). Composite resin cylinders were added to the tested surfaces. The specimens were kept in distilled water (37°C/24 h), thermocycled for 500 cycles (5°C-55°C) and submitted to shear testing at a crosshead speed of 0.5 mm/min. The type of fracture was analyzed under stereomicroscopy and the data were submitted to Anova, Tukey and Chi-squared (5%) statistical analyses. The mean adhesive strengths were G1: 18.13 ± 6.49 MPa, (55% of resin cohesive fractures); G2: 17.12 ± 5.80 MPa (90% of adhesive fractures); and G3: 10.47 ± 3.14 MPa (85% of adhesive fractures). In terms of bond strength, there were no significant differences between G1 and G2, and G3 was significantly different from the other groups. G1 presented a different type of fracture from that of G2 and G3. In conclusion, although the total etching and self-etching systems presented similar shear bond strength values, the types of fracture presented by them were different, which can have clinical implications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji II LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37°C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm2) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (α = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji II LC (10.29 MPa) and the other two materials (p > 0.05). Fuji II LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of surface conditioning methods and thermocycling on the bond strength between a resin composite and an indirect composite system in order to test the repair bond strength. Materials and Methods: Eighteen blocks (5 x 5 x 4 mm) of indirect resin composite (Sinfony) were fabricated according to the manufacturer's instructions. The specimens were randomly assigned to one of the following two treatment conditions (9 blocks per treatment): (1) 10% hydrofluoric acid (HF) for 90 s (Dentsply) + silanization, (2) silica coating with 30-Ìm SiOx particles (CoJet) + silanization. After surface conditioning, the bonding agent was applied (Adper Single Bond) and light polymerized. The composite resin (W3D Master) was condensed and polymerized incrementally to form a block. Following storage in distilled water at 37°C for 24 h, the indirect composite/resin blocks were sectioned in two axes (x and y) with a diamond disk under coolant irrigation to obtain nontrimmed specimens (sticks) with approximately 0.6 mm2 of bonding area. Twelve specimens were obtained per block (N = 216, n = 108 sticks). The specimens from each repaired block were again randomly divided into 2 groups and tested either after storage in water for 24 h or thermocycling (6000 cycles, 5°C to 55°C). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using two-way ANOVA (α = 0.05). Results: Both surface conditioning (p = 0.0001) and storage conditions (p = 0.0001) had a significant effect on the results. After 24 h water storage, silica coating and silanization (method 2) showed significantly higher bond strength results (46.4 ± 13.8 MPa) than that of hydrofluoric acid etching and silanization (method 1) (35.8 ± 9.7 MPa) (p < 0.001). After thermocycling, no significant difference was found between the mean bond strengths obtained with method 1 (34.1 ± 8.9 MPa) and method 2 (31.9 ± 7.9 MPa) (p > 0.05). Conclusion: Although after 24 h of testing, silica coating and silanization performed significantly better in resin-resin repair bond strength, both HF acid gel and silica coating followed by silanization revealed comparable bond strength results after thermocycling for 6000 times.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static load Knoop). The specimens were submitted to 6- or 18-h cycles in the tested media. The solutions were refreshed at the end of each cycle. All solutions were stored for further analysis. After 15-day storage, the final surface microhardness (FSM) and fluoride release were measured. Fluoride dose was measured with a fluoride-specific electrode (Orion 9609-BN) and digital ion analyzer (Orion 720 A). The variables ISM, FSM and fluoride release were analyzed statistically by analysis of variance and Tukey's test (p<0.05). There was significant difference in FSM between the storage media for Vitremer (pH 4.6 = 40.2 ± 1.5; water = 42.6 ± 1.4), Ketac-Fil Plus (pH 4.6 = 73.4 ± 2.7; water = 58.2 ± 1.3) and Fluorofil (pH 4.6 = 44.3 ± 1.8; water = 38.4 ± 1.0). Ketac-Fil Plus (9.9 ± 18.0) and Fluorofil (4.4 ± 1.3) presented higher fluoride release in water, whereas Vitremer (7.4 ± 7.1), Fuji II LC (5.7 ± 4.7) and Freedom (2.1 ± 1.7) had higher fluoride release at pH 4.6. Microhardness and fluoride release of the tested restorative materials varied according to the storage medium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calathea louisae is an herbaceous ornamental plant native of Brazil whose cut foliage has potential to be used as a new product for the local ornamental market, as well as the international market, due to its decorative dark green leaves with greenish white splotches along midrib, and purple undersides. The objective of this study was to evaluate pulse treatments of benzyladenine and gibberellic acid for maintaining quality and extending keepability of foliage. The experiment was conducted in a complete randomized design with three replications (three stems in each vase) and seven treatments: distilled water (control) and pulsing cut petioles in benzyladenine or gibberellic acid for 4 h at 100, 250 and 500 mg L-1. The senescence symptoms were characterized by leaf rolling and a decrease in the angle formed between leaf and petiole as a response to water stress. Gibberellic acid or benzyladenine pulse treatments (250 and 500 mg L-1) significantly extended the longevity of cut foliage compared to the control. Gibberellic acid pulse (250 and 500 mg L-1) maintained leaves' green coloration and brightness for a longer time compared to control and benzyladenine pulse. Pulsing with gibberellic acid or benzyladenine (at all tested concentrations) maintained upright leaves for a longer time, showing a significantly higher angle between leaf and petiole compared to control. Foliage pulsed with gibberellic acid (500 mg L-1) showed a significantly higher leaf relative water content, a significantly smaller loss of accumulated fresh mass percentage compared to control and other gibbberellic acid and benzyladenine treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Toothpastes usually contain detergents, humectants, water colorant, fluoride and thickeners (e.g. silica). Tooth wear has a multi-factorial etilology and the use of abrasive dentifrices is related to abrasion of dental tissues during toothbrushing. This study evaluated in vitro the abrasiveness of a commercial silica gel low-abrasive dentrifice compared to an experimental dentifrice containing vegetable (almond) oil. Distilled water served as a control group. Acrylic specimens (8 per group) were submitted to simulated toothbrushing with slurries of the commercial dentifrice experimental dentifrice, almond oil and water in an automatic brushing machine programmed to 30,000 brush strokes for each specimen which is equivalent to 2 years of manual toothbrushing. Thereafter, surface roughness (Ra) of the specimens was analyzed with a Surfcorder SE 1700 profilometer. Data were analyzed statistically by ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) in the surface roughness after brushing with water almond oil experimental dentifrice. The commercial dentifrice produced rougher surfaces compared to the control and abrasive free products (p<0.05). Further studies are necessary in confirm the potential benefits of using vegetable oil in toothpaste as an alternative in abrasives in an attempt to minimize the tooth wear caused by toothbrushing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to evaluate the dynamic performance of an agricultural tractor utilizing distilled biodiesel (50% ethylic + 50% methylic) as a function of the proportion of biodiesel and diesel of petroleum (0 and 100%, 5 and 95%, 15 and 85%, 25 and 75%, 50 and 50%, 75 and 25% and 100 and 0%), respectively. This research was done in the area of the Department of Rural Engineering of the Paulista State University (UNESP), Jaboticabal Campus, SP, located in the latitude 21° 14′ 28″ S and longitude 48° 17′12″ W. A tractor 4 x 2 FWA was used, with a 73.6 kW (100 HP) motor and a ballast tractor. The biodiesel used was produced from spent oil from food frying. The experimental design was entirely randomized, with 7 treatments and 5 repetitions, totaling 35 observations. The results showed that the biodiesel and diesel blend significantly influenced the hourly volumetric consumption, hourly mass consumption, fuel consumption per worked area and specific fuel consumption variables. When the tractor operated with 100% of biodiesel (B100) the specific fuel consumption increased 18% on average in relation to diesel (B0).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to identify treatments capable of promoting and standardizing the germination of Murdannia nudiflora (L.) Brenan seeds. The seeds of this weed were submitted to the following treatments: mechanical abrasion with 220-grit sandpaper (20, 30 and 40 frictions); immersion in sulfuric acid (90% for 30 and 40 seconds), followed by washing in running water; immersion in sodium hypochlorite (2.5% for 8 and 12 hours) and lye (5 minutes), followed by five washings in distilled water; immersion in KNO 3 (1% for 24 hours); preheating at 40°C in a humid or dry substrate for 2, 3 and 4 weeks. The statistical design was totally randomized, with four repetitions. The number of germinated seeds was counted every other day. The most favorable treatments were preheating at 40°C in humid substrate for 3 weeks, followed by mechanical abrasion after 40 frictions and immersion in sulfuric acid for 40 seconds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The plant species Phalaris canariensis, known as canary grass, is widely used in folk medicine as diuretic, as well as in culinary and animal feed. In this study, the effect of P. canariensis aqueous extract (AE) on water flow (V) and sodium renal excretion (Qe (Na+)) was evaluated in anesthetized Wistar rats. Arterial pressure alterations (AP) were also assessed. Two groups were studied: Control group (CON) - oral administration of 1.0 mL distilled water, and Experimental group (EA) - oral administration of 1.0 mL P. canariensis aqueous extract 40%. Rats were anesthetized and subjected to cannulation of trachea (for better pulmonary ventilation), left carotid artery (for arterial pressure measurement) and urinary bladder (for urine collection). Control animals did not present significant alterations (p>0.05) in all analyzed parameters after water administration. EA group had a significant arterial pressure reduction at 60 minutes (31.4%) and 90 minutes (49.1%) after the extract administration (p<0.05). Renal parameters did not have any significant alteration (p>0.05). In this study, P. canariensis aqueous extract had a hypotensive effect in anesthetized Wistar rats, without renal alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Marantaceae leaves have a contrasting color pattern and a decorative design which are interesting traits for its use as cut foliage. No postharvest research has been carried out on the potential as cut foliage for species of Ctenanthe, a member of the Marantaceae. Grey-maranta (Ctenathe setosa) is an herbaceous ornamental plant native of Brazil whose cut foliage has potential to be used as new crop product for local and international ornamental markets. The objective of this study was to evaluate pulse treatments to extend the longevity of foliage. The experiment was conducted in a complete randomized design with three replications and eight treatments: distilled water; pulsing cut petioles-ends in citric acid (pH = 2.8/1h); 2% sucrose (4h); 1% sucrose plus 200 mg L-1 citric acid (4h); 0.01% Tween® 20 (4h); 100 mg L -1 benzyladenine plus 0.01% Tween® 20 (4h); 100 mg L-1 gibberellic acid plus 0.01% Tween® 20 (4h); and maintenance of cut petiole in holding solution with commercial sodium hypochlorite (0.5 mL L-1). The senescence symptoms were mainly characterized by leaf rolling and by a decrease in the angle formed between leaf and petiole as a response to water deficit stress. Gibberellic acid or benzyladenine pulse treatments significantly extended longevity (6 days compared to control) and maintained leaves' green coloration and brightness for a longer time compared to control. However, only the benzyladenine plus Tween® 20 pulse maintained leaves in an erect form for a longer time, showing a significantly higher angle between leaf and petiole compared to control. Also, foliage pulsed with benzyladenine plus Tween® 20 showed a significant smallest loss of accumulated fresh mass percentage compared to control by the T test as to parallelism of treatments lines.