497 resultados para Dentin adhesives
Resumo:
Introduction: It is known that self-etching adhesive systems can act as semi-permeable membranes. Objective: Evaluate the effects of additional layer of hydrophobic resin on the microtensile bond strength of self-etching one-bottle adhesives. Material and method: Sixty bovine incisors were used in this study. The facial enamel surfaces of the crowns were abraded with silicon carbide paper to expose flat, mid-coronal dentin surfaces. The following adhesives were used: Clearfil Tri S Bond (CTSB), AdheSE One (ADH) and One Coat 7.0 (OC). Each material was tested with and without applying an additional layer of hydrophobic material from the same manufacturer. Z-350 composite resin was inserted in three 1 mm increments. All adhesive restorative procedure was performed under simulated pulpal pressure and the microtensile test was performed immediately after curing the composite resin. Data were submitted to ANOVA and Tukey test (p < 0.05). Result: For all adhesives tested, the worst results were observed in groups which the additional layer of hydrophobic resin was not applied. Conclusion: The application of additional layer of hydrophobic material can improve the adhesion of self-etching all-in-one adhesive systems.
Resumo:
The knowledge of the etiology of any disease or condition is paramount to a safe and effective treatment. This literature review aims to show some options to treat dentine hypersensitivity (HSDC). The loss of cervical enamel and cementum exposure of tubules leads to a painful condition and patient discomfort, called HSDC. This loss of tooth structure occurs due to formation of cervical lesions in cases of gingival recession, abrasion, erosion, or abfraction by the association of two or more factors. Some treatments are not effective, but there are effective therapies, such as: application of ferric oxalate, potassium oxalate, potassium nitrate, fluoride varnish, solutions of calcium phosphate, adhesives and Bonding procedures. Therefore, the identification and removal of etiological factors is essential to successful treatment of HSDC normally associated to tubules obliterate and consequent reduction of fluid motion within the dentin.
Resumo:
Purpose: The purpose of this study was to evaluate the increase of the cervical area and dentin thickness in mesial and distal walls of the mesial canals from mandibular molars after the use of LA Axxess (LA), CP Drill (CP) and Gates-Glidden (GG) rotary instruments. Material and Methods: Sixty root canals from thirty mandibular first molar were sectioned 3 mm below the cement-enamel junction, divided in 3 groups (n = 20 root canals, each) according to rotary instrument used, and the cervical images were captured before and after pre-enlargement instrumentation. The increase of the instrumented cervical area (mm2) and the dentin removal thickness (mm), at mesial and distal walls were calculated using Image tools software, by comparison of images. Data were analyzed by ANOVA and Tukey tests (p=0.05). Results: All rotary instruments promoted thickness reduction in dentin walls. In mesial wall, all rotary instruments promoted similar thickness reduction of dentinal wall and did not differ from each other (p>0.05). In distal wall, LA Axxess instrument promoted higher dentin thickness reduction than other groups (p<0.05). The three rotary instruments promoted different increase at the instrumented cervical area (p<0.05), LA promoted the highest increase area and GG and CP presented similar results. Conclusion: LA 20/0.06 promoted the highest thickness reduction in distal wall and increase of cervical area of root canal. On the other hand, CP was the safest instrument, with lower dentin removal of distal wall and similar increased area to GG.
Resumo:
Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealer-contaminated dentin.
Resumo:
This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.
Resumo:
Introduction: Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealercontaminated dentin.
Resumo:
Ideally projected to be applied on soft tissues, infrared lasers were improved by restorative dentistry to be used in hard dental tissues cavity preparations-namely enamel and dentin. This paper evidentiates the relevant aspects of infrared Erbium laser's action mechanism and its effects, and characterizes the different effects deriving from the laser's beams emission. The criteria for use and selection of optimal parameters for the correct application of laser systems and infuence of supporting factors on the process, such as water amount and its presence in the ablation process, protection exerted by the plasma shielding and structural factors, which are indispensable in dental tissues cavity preparation related to restorative technique, are subordinated to optical modifcations caused by the interaction of the energy dissipated by these laser light emission systems in the targeted tissue substrate. Clinical relevance: Differences in the action of infrared Erbium laser system in regard to the nature of the ablation process and variations on the morphological aspects observed in the super-fcial structure of the target tissue irradiated, may be correlated to the structural optical modifcations of the substrate produced by an interaction of the energy propagated by laser systems.
Resumo:
This study sought to assess the use of chlorhexidine with several excipients as a dentin surface treatment and its effect on marginal adaptation of class V restorations with current-generation dentin bonding agents. A total of 120 human third molars were selected and allocated into 12 groups, with standardized buccal class V restorations randomly divided into preconditioned dentin rinsed with: water; water + chlorhexidine; ethanol; or ethanol + chlorhexidine. After rinsing of dentin (previously conditioned with 35% phosphoric acid) with the test solutions, the Adper single bond 2, prime and bond 2.1, and Excite bonding systems were applied randomly. Restorations were performed with FiltekTM Z350 XT composite resin. The resulting specimens were subjected to thermal and mechanical load cycling. Quantitative analysis of marginal adaptation was performed on epoxy replicas by means of scanning electron microscopy. Results were assessed by means of the Kruskal-Wallis test (percentages of continuous margins) and Wilcoxon test (differences between percentages of continuous margins before and after thermal cycling and mechanical loading), at a significance level of p < 0.05. Outcomes in the chlorhexidine-treated groups were not superior to those obtained with other treatments.
Resumo:
The aim of this study was to compare the hydraulic conductance in human dentin disks, where 1, 2 or 3 layers of adhesive Single Bond 2(SB2) and Single Bond Universal(SBU) were applied. 84 1 mm. thick(+/- 0.1 mm.) dentin disks were fabricated. Samples were divided into 7 groups (n = 12) Control (without adhesive), A1: one layer of SB2, A2: two layers SB2, A3: three layers SB2, B1: one layer SBU, B2: two layers of SBU, B3: three layers of SBU. The results as averages for the hydraulic conductance of each separate group were: Control (0.0363), A1 (0.0206), A2 (0.0070), A3 (0.0061), B1 (0.0161), B2 (0.0062), B3(0.0056) expressed µl/min.cm2. There is statistically significant difference CH, between the control group and those samples that one coat was applied (p = 0.000) and also between the application of one and two layers (p = 0.000). No difference between the two adhesives (p = 0.434). Summary Key words: Dentin, conductance, difussion adhesive layers.
Resumo:
Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments.
Resumo:
Aim The aim of the present study was to evaluate the effect of three different formulations of sodium hypochlorite on the microhardness of root canal dentin in cervical and apical segments. Methods Twenty-four extracted human teeth had their roots sectioned along their long axes in a buccolingual direction. One half of each root was selected, and transversely sectioned resulting in two segments, cervical and apical, with similar lengths. The specimens were divided into three groups (n = 16), according to the sodium hypochlorite formulation used: (a) group 1, 2.5% sodium hypochlorite; (b) group 2, Chlor-XTRA; and (c) group 3, 5.5% sodium hypochlorite gel. These groups were subdivided in two subgroups (n = 8): cervical and apical root segments. Before testing the substances, dentin microhardness was measured on each section, 100 μm from the root canal with a Knoop tester. After 15 min of application, a new measurement was performed on each segment. Data were collected and registered for statistical treatment. Results In both segments, the substances reduced dentin microhardness. No differences were observed between the groups, independent of the analyzed segment (P > 0.05). Conclusions All substances reduced dentin microhardness. Chlor-XTRA and 5.5% sodium hypochlorite gel promoted a reduction similar to the 2.5% sodium hypochlorite solution.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)