358 resultados para cylindrical grinding


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat treatment); treatment 1 (T1): heating at 750°C for 2 h; and treatment 2 (T2): annealing at 955°C for 1 h and aging at 620°C for 2 h. After heat treatments, the specimens were embedded in acrylic resin and their surface was ground and polished and hardness was measured. Vickers hardness means (VHN) and standard deviations were analyzed statistically by Kruskal-Wallis test at 5% significance level. For commercially pure titanium, Vickers hardness means of group T2 (259.90 VHN) was significantly higher than those of the other groups (control - 200.26 VHN and T1 - 202.23 VHN), which presented similar hardness means to each other (p>0.05). For Ti-6Al-4V alloy, statistically significant differences were observed among the three groups: T2 (369.08 VHN), T1 (351.94 VHN) and control (340.51 VHN) (p<0.05). The results demonstrated different hardness of CP Ti and Ti-6Al-4V when different heat treatments were used. For CP Ti, VHN means of T2 group was remarkably higher than those of control and T1 group, which showed similar VHN means to each other. For Ti-6Al-4V alloy, however, VHN means recorded for each group may be presented as follows: T2>T1>control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To describe the normal bony orbital structure of the large fruit-eating bat (Artibeus lituratus) with emphasis on a unique intraorbital bony structure previously not described in the literature. Procedures: The bony anatomy of the orbital cavity was studied on dissected skulls of large fruit-eating bats. The anatomic description of a unique intraorbital spine was made while studying the bony orbit of macerated skulls. Additional observations were made on dissected formalin-fixed whole heads. Both procedures were performed under a stereo dissecting microscope, using ×2-4-magnification. A histologic analysis of soft tissues surrounding this cylindrical bony structure was performed using cross and longitudinal oblique sections from decalcified whole heads, which had been fixed in formalin. Additionally, biometric measurements and a histomorphometric analysis were performed. Results and conclusions: An intraorbital cylindrical osseous structure measuring 3.96 ± 0.68 mm in length and 155.62 ± 14.03 μm in diameter was observed in the large fruit-eating bat (A. lituratus), creating a unique orbital structural design among mammals. We suggest the name optic spine of the alisphenoid bone. The anatomic, biometric and histologic characterization of this element might contribute to a further understanding of the dynamics of bat vision and the sort of factors that influenced evolution of the visual system of microbats. The authors hope that the documentation of this distinctive anatomic feature will also expand the debate about the phylogenetic analysis of the relationship among bat species in the near future. © 2007 American College of Veterinary Ophthalmologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Achyrocline alata occurs in a dense and low vegetation in Mato Grosso do Sul State, Brazil and it has been studied under physical-chemical and yield aspects, being scarce anatomical data. The present work has as objective the study of the aerial vegetative axis. Stem is cylindrical and hairy, having five wings, which are arisen from their leaves. The blade shows the presence of uniseriate epidermis, which is covered by the cuticle of variable thickness; and non-glandular and glandular trichomes. The non-glandular trichomes are uniseriate and multicellular and have their apex cell in whip form, while the glandular trichomes are multicellular, uniseriate or biseriate. The mesophyll is dorsiventral with uni-stratified palisade parenchyma in most of the cases and lacunal parenchyma formed by three to four layers of irregular cells. Only one collateral vascular bundle occurs in the midvein. Stem in transversal section is covered by epidermis with trichomes similar to leaves; the cortex is constituted by a discontinuous area of angular collenchyma, which is followed by chlorophyll parenchyma. Vascular cylinder that is delimited by pericycle shows vascular bundles of collateral type. In the secondary structure, the periderm is originated from epidermal and subepidermal tissues. In vascular region, the fascicular cambium differs into secondary xylem and phloem, while interfascicular cambium produces sclerenchymatous tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents specific cutting energy measurements as a function of the cutting speed and tool cutting edge geometry. The experimental work was carried out on a vertical CNC machining center with 7,500 rpm spindle rotation and 7.5 kW power. Hardened steels ASTM H13 (50 HRC) were machined at conventional cutting speed and high-speed cutting (HSC). TiN coated carbides with seven different geometries of chip breaker were applied on dry tests. A special milling tool holder with only one cutting edge was developed and the machining forces needed to calculate the specific cutting energy were recorded using a piezoelectric 4-component dynamometer. Workpiece roughness and chip formation process were also evaluated. The results showed that the specific cutting energy decreased 15.5% when cutting speed was increased up to 700%. An increase of 1 °in tool chip breaker chamfer angle lead to a reduction in the specific cutting energy about 13.7% and 28.6% when machining at HSC and conventional cutting speed respectively. Furthermore the workpiece roughness values evaluated in all test conditions were very low, closer to those of typical grinding operations (∼0.20 μm). Probable adiabatic shear occurred on chip segmentation at HSC Copyright © 2007 by ABCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work used four cylindrical PVC (polyvinyl chloride) mini compost bins, they all had the same size and were identical, with 40 cm diameter and 75 cm length, they also were opened on both sides. Each mini compost bean received 35,5 kg of solid organic wastes, which were previously crushed and 6 kg of sawdust. It was evaluated during the composting process the C/N analyses, temperature measurement, humidity and pH. Results showed that the use of sawdust as a source of high carbon inputs on the mini compost beans and using low quantities of organic solid wastes reached temperatures as high as 65° C, keeping on the thermophilic phase for almost 6 days. After 18 days the environmental temperature was reached, the organic wastes were then laid to reach full maturity for 55 more days. The C/N ratio was initially around 30/1 and after 73 days it was around 12/1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study was conducted in twenty-three butcheries in the city of Taquaritinga, State of São Paulo, Brazil, surveyed during a 10 months period. Among two hundred and eighty-seven Escherichia coli strains isolated from samples of ground beef, meat-grinding-machines and the hands of manipulators, five were recognized as extraintestinal pathogenic E. coli (ExPEC), showing virulence factors (P and S fimbriae, hemolysin and aerobactin) and presenting multidrug resistance. Retail-sold food may constitute an important vehicle for the dissemination of ExPEC in communities, giving rise to reasons for concern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate, at different times, the diametral tensile strength (DTS) of dual-curing resin cements that were not photopolymerized. METHOD AND MATERIALS: Equal amounts of base and catalyst pastes of Panavia F (Kuraray), Variolink II (Vivadent), Rely X (3M ESPE), and Enforce (Dentsply) were mixed and inserted into cylindrical molds (4 x 2 mm) (n = 10). Cements were not photopolymerized. DTS test was performed in a testing machine at 30 minutes, 1 hour, 24 hours, and 7 days. The specimens were stored in light-proof containers with distilled water at 37 degrees C until the time of assay. An autopolymerizing resin cement (Cement-It, Jeneric Pentron) and a zinc phosphate cement served as controls. One-way analysis of variance (ANOVA) and Tukey test were performed separately for each cement and for each time (P <.05). RESULTS: All cements showed an increase in DTS when tested at 1 and 24 hours. Tests at 24 hours and 7 days revealed no statistically significant differences. In all groups, the zinc phosphate cement had the lowest DTS mean values (2.1 MPa, 3.6 MPa, 6.5 MPa, and 6.9 MPa), while Cement-It (35.1 MPa, 33.6 MPa, 46.9 MPa, and 46.3 MPa) and Enforce (31.9 MPa, 31.7 MPa, 43.4 MPa, and 47.6 MPa) presented the highest DTS mean values. CONCLUSION: All cements presented maximal strength at 24 hours. The dual-curing resin cements, even when nonphotopolymerized, demonstrated higher DTS than the zinc phosphate cement and similar or lower values than the autopolymerizing resin cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work results are presented of laboratory tests aiming to evaluate the possibility of using concrete wastes in manufactured soil-cement pressed bricks. Tests of characterization of used soil of the composite of this soil with concrete wastes and of the mixtures of soil cement made with this composite were evaluated. According to results of tests carried out with cylindrical specimens and with soil cement pressed bricks, it was verified that the addition of the concrete wastes improved soil cement mechanical properties, favoring the a reduction of the cement consumption, obtaining pressed bricks with a better quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The knowledge of dental occlusion should be considered the basic foundation to an excellent orthodontic practice. The patient's diagnose without the centric relation assessment can take the orthodontist to an unpleasant surprises. The use of rectangular archwires requires occlusal contacts been checked to decide what kind of the dental movement will be necessary to achieve the dental equilibrium and mainly to investigate if the movement will be possible. Considering the occlusal surfaces complexity, the occlusal adjustment by selective grinding should be performed during the orthodontic treatment to allow vertical dental movements reducing treatment's time. Occlusal interferences are responsible not only for biomechanics adverse effects, producing undesirable dental movements, but also for potential side effects such as excessive forces (occlusal trauma), leading to roots reabsorption. The occlusal adjustment is a determinant point on dental balance after the end of orthodontics treatments, where each posterior occlusal tooth contacts A and B, or B and C on buccolingual aspect, as well as the stoppers and equalizers contacts on mesiodistal direction must be achieved and well established. The appropriate role of anterior teeth in mandibular movements must be determined, allowing immediate disclusion of posterior teeth, known as anterior guide, and promoting protecting muscle forces to the stomatognathic system. Selective grinding should not be used. in place of well planned and executed orthodontic movement. Aim: The aim of this article is to present the rationale use of occlusal adjustment in Orthodontics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the effect of bleaching agents on the microhardness of nanoparticle resin composite. Methods: Twenty-eight cylindrical test specimens (8× 1mm) of Filtek™ Supreme XT resin (3M/ESPE) were prepared and divided into 5 groups. The initial Vickers microhardness was measured (load of 50 grams force for 30 seconds) on the top surface of the test specimens. The groups were treated and divided as follows: G1 - artificial saliva (21 days - control); G2 - 7% hydrogen peroxide gel applied for 4h/day, for 14 days; G3 - 10% carbamide peroxide for 4h/day, for 14 days: G4 - 35% hydrogen peroxide gel applied in three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions; G5 - 35% carbamide peroxide, three sessions of 30 minutes each, with an interval of one week (21 days) between the sessions. The top surfaces of the test specimens received treatment and were submitted to the Vickers microhardness test. Results: The results obtained were submitted to the Analysis of Variance at a fixed criterion, at a level of significance of p=0.05. No significant differences were observed among the treatments tested (p=0.42) when compared with G1. Significant differences (Tukey test) were found when the initial microhardness values were compared with the values after experimental treatments (p<0.01). Conclusion: The application of bleaching agents did not alter the microhardness of resin composites. Therefore, there is no need to change restorations after bleaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the investigation of an abrasive process for finishing flat workpieces, based on the combination of important grinding and lapping characteristics. Instead of loose abrasive grains between the workpiece and the lapping plate, a resinoid grinding wheel of hot-pressed silicon carbide is placed on the plate of a device resembling a lapping machine. The resin bond grinding wheel is dressed with a single-point diamond. In addition to keeping the plate flat, dressing also plays the role of interfering in the behavior of the process by varying the overlap factor (Ud). It was found that the studied process simplify the set-up and can be controlled more easily than in lapping, whose is a painstaking process. The surface roughness and flatness deviation proved comparable to those of lapping, or even finer than it, with the additional advantage of a less contaminated workpiece surface with a shiny appearance. The process was also monitored by acoustic emission (AE), which indicates to be a promissing and suitable technique for use in this process. Copyright © 2008 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft linings are materials used to reduce the tension and forces of mastication, forming all or part of the fitting surface of a denture. This study evaluated the effect of thermocycling on water absorption, solubility, Shore A hardness and color stability of permanent soft liner materials. MATERIAL AND METHODS: Two chemically activated soft liner materials (Sofreliner S; GC Reline Ultrasoft) were tested. Twenty cylindrical specimens (30.0 x 1.0 mm) were prepared for measuring water absorption and solubility and another twenty (30.0 x 3 mm) for analyzing Shore A hardness and color stability. Color was measured by a spectrophotometer before and after 2000 thermocycles. A one-way ANOVA test and Tukey test at a 5% confidence level (p<0.05) were performed. RESULTS: The results did not show statistical differences for water absorption, solubility or color stability. The post-thermocycling Shore A hardness values were significantly higher than those before the treatment. CONCLUSION: Thermocycling of soft liner materials increased Shore A hardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this in vitro study was to evaluate the surface roughness of three glass ionomer cements (GICs) indicated for ART restorations. Methods: Ten cylindrical specimens of three commercial glass ionomers cements (Vidrion R - S.S. White, Maxxion R - FGM and Vitromolar DFL) were prepared (n=30) without surface finishing or protection. Twenty-four hours after preparation, the surface roughness measurements were obtained as the mean of three readings of the surface of each specimen by profilometry. The roughness values (Ra, μm) were subjected to one-way ANOVA and Tukey's test (p<0.05). Results: No statistically significant differences were observed between Vidrion R (0.18 ± 0.05) and Vitromolar (0.21 ± 0.05), whereas Maxxion R presented significantly higher roughness values than those of the other materials. Conclusions: It may be concluded that characteristics of particle size and composition of the different GICs affected their surface roughness 24 h after preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Petrobras produced green petroleum coke (GPC) is a carbon rich fuel, virtually ash-free, with low sulfur content, and is a fuel suitable to replace metallurgical coke in blast furnaces. The GPC was tested in a pulverized coal injection simulator built in the Volta Redonda research center. It presented a low burning efficiency due to low volatile material content and high substitution rate by the carbon content. The tests were carried out in blast furnaces with ≤ 50% Petrobras GPC in the coal blends. The injected coal/CVP mixtures produced no negative side effects in the blast furnace grinding systems, pneumatic conveying, or operating process. The mixture burning process inside the blast furnace showed a decrease in fuel consumption, with a significant reduction in metallurgical coke consumption. The industrial-scale tests of the GPC mixtures did not reach the 70% maximum for lack of the GPC feedstock, which is necessary to continue with standard coal mixtures.