257 resultados para Repeated Measures


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To compare the cyclosporine 0.05 % exposure effect on fibroblasts from primary and recurrent pterygium. Primary culture of fibroblasts from primary and recurrent pterygium was performed until the third passage, which was exposed to cyclosporine 0.05 % in a group and the other remaining unexposed (control group), in triplicates. After 3, 6, 12, and 17 days of exposure the viable cell counting was performed by hemocytometer. The results were statistically analyzed using the technique of analysis of non-parametric variance model for repeated measures with three factors. There was a significant reduction in both fibroblast proliferation, in primary as in the recurrent pterygium cultures exposed to cyclosporine when compared not exposed cultures, with statistical significance (P < 0.05). Comparing primary and recurrent pterygium that received the drug, there was no significant difference in cell proliferation in relation to primary or recurrent pterygium. Cyclosporine 0.05 % is effective in inhibiting fibroblast proliferation in culture, both in primary and as in recurrent pterygium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate the change in masticatory efficiency and quality of life of patients treated with mandibular Kennedy class I removable partial dentures (RPDs) and maxillary complete dentures at the Department of Dentistry of the Federal University of Rio Grande do Norte. A total of 33 Kennedy class I patients were rehabilitated with maxillary complete dentures, and mandibular RPDs were selected for this non-randomized prospective intervention study. The patients had a mean age of 59.1 years. Masticatory efficiency was evaluated by colorimetric assay using fuchsin capsules. The measurements were conducted at baseline and 2 and 6 months after prosthesis insertion. Quality of life was evaluated using the Oral Health Impact Profile (OHIP-14) at baseline and 6 months after denture insertion. The Kolmogorov-Smirnov normality test was applied. Masticatory efficiency was evaluated by repeated measures ANOVA. Oral health-related quality of life was compared using the paired t test. There was no statistically significant difference in masticatory efficiency after denture insertion (p = 0.101). Significant differences were found (p = 0.010) for oral health-related quality of life. A significant improvement in psychological discomfort (p < 0.01) and psychological disability (p < 0.01) was observed. Mean difference value (95 % confidence interval) was 6.8 (3.8 to 9.7) points, reflecting a low impact of oral health on quality of life, considering the 0-56 range of variation of the OHIP-14 and a Cohen's d of 1.13. According to the results of the present study, rehabilitation with Kennedy class I RPDs and complete dentures did not influence masticatory efficiency but improved oral health-related quality of life. The association between the patient's quality of life and the masticatory efficiency is important for treatment predictability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to investigate the effect of recovery time after quadriceps muscle fatigue on gait in young adults. Forty young adults (20-40 years old) performed three 8-m gait trials at preferred velocity before and after muscle fatigue, and after 5, 10 and 20min of passive rest. In addition, at each time point, two maximal isometric voluntary contractions were preformed. Muscle fatigue was induced by repeated sit-to-stand transfers until task failure. Spatio-temporal, kinetic and muscle activity parameters, measured in the central stride of each trial, were analyzed. Data were compared between before and after the muscle fatigue protocol and after the recovery periods by one-way repeated measures ANOVA. The voluntary force was decreased after the fatigue protocol (p<0.001) and after 5, 10 and 20min of recovery compared to before the fatigue protocol. Step width (p<0.001) and RMS of biceps femoris (p<0.05) were increased immediately after the fatigue protocol and remained increased after the recovery periods. In addition, stride duration was decreased immediately after the fatigue protocol compared to before and to after 10 and 20min of rest (p<0.001). The anterior-posterior propulsive impulse was also decreased after the fatigue protocol (p<0.001) and remained low after 5, 10 and 20min of rest. We conclude that 20min is not enough to see full recovery of gait after exhaustive quadriceps muscle fatigue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Regular physical activity can prevent and treat various diseases and non-communicable diseases such as diabetes, hypertension, obesity and cardiovascular disease. However, the prevalence of physical inactivity among adolescents in Rio Claro is 83%. Thus, it is necessary to encourage physical atividade through the community, especially parents and schools. The objective was to investigate the influence of two types of gym class in functional abilities in high school students in the city of Rio Claro-SP. Methodology: The study included 20 students from high school, 8 boys and 12 girls. The study took place in two high school halls of a public school in the city of Rio Claro. With the collaboration and participation in only 10 students in each room search reviews of all students occurred in mid-July in the year 2012 with the completion of the battery of tests and application of PAQ-C questionnaire at the beginning of classes of and after three months. All students were subjected to the test battery Eurofit. To compare the values of physical fitness for each type of class was held factorial ANOVA for repeated measures using SPSS and the level of physical activity was performed the Wilcoxon test. To compare the delta values (post-test-time time pre test every physical fitness) we performed the t test for all analyzes was adopted p <0.05 Classes G1 followed the schedule proposed by the state 's Notebook, where he worked subjects as body and beauty and its relationship with the media today, prevailing more conceptual classes than procedural . Unlike what has been developed with the G2 who had classes were focused on physical fitness and physical conditioning to increase the level of physical activity inside and outside the school environment . Result :The results from the data collected in this study indicate that physical fitness is not worked continuously or expressive within the Physical Education classes of high school to the population...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among the numerous possibilities of physical exercise, it has been recommended that stretching routines should be incorporated into training programs focused on the elderly population, and that these routines should be preferentially performed on the same strength or aerobic training session. However, studies have shown that muscle strength production can be acutely impaired if it is preceded by static stretching exercises (AE). Although there seems to be a relationship between the number of stretched muscles and strength response, no studies were found examining such relationship in the same study, simultaneously. Thus, the objective of this study is to analyze the acute effect of stretching of different muscle groups on strength performance in older women. Nineteen physically active older women participated in the study (67.8 ± 5.3 years, 68.9 ± 12.4 kg, 157.2 ± 6.4 cm)-usar ponto final em inglês e não vírgula. The participants visited the lab for six consecutive days, three of which were intended to familiarization. Over the next three days, all the participants performed the experimental conditions: control; quadriceps stretching alone and complete stretching, involving the major extensors muscle groups of knees and hips. Both the two stretching conditions were realized with three series of 30s (total volume of 90 seconds for each exercise). All experimental conditions was be performed with an interval of at least 24 hours and order of execution was be randomized. The force transducer was connected to a leg press apparatus, where the isometric force time curve and electromyographic activity of the vastus medial and vastus lateralis were recorded. Measurements were registered immediately after each experimental condition, during five seconds. Statistical analysis comprised descriptive procedures and the One way ANOVA test for repeated measures (p<0.05). No statistically significant differences between the control and the two...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several methods are used towards delayed onset muscle soreness appraisal. This study's goal was to investigate, amongst three commonly adopted methods, which one would be the most effective (the one that shows higher values) in the quantification of this phenomenon. 10 male subjects, of age 22.8 ± 3.1 years old, weight 80 ± 12.4 kg, height 174 ± 0.07 cm, without recent experience with strength training (lower limbs) and/or running took place in this study. All subjects carried out a muscle damage induction protocol, which consisted of 30 minute downhill running (-16% or -9.09º) at 80% speed compared to their maximum oxygen consumption. Muscle damage determinants such as isometric peak torque, knee joint range of motion and circumference of the medial portion of the thight were measured before, during, 24, 48, 72 and 96 hours after downhill running. The subjective pain perception was measured simultaneously with the other determinants through three different tests: sitting on and getting up of a chair; climbing and descending from a 45cm step; and self thigh palpation. After going through all subjective pain perception tests, the subjects filled out a visual analog scale with their perception of pain. Muscle damage changes over time were compared through variance analysis (ANOVA) one way for repeated measures. Subjective pain perception values obtained in all three different tests were compared through two way ANOVAs for repeated numbers. The significance level adopted in this study was z ≤ 0.05. The results showed that the step test was the on which better evaluated the delayed onset muscle soreness. No significant differences were found through the ADM and CIR recovery markers. Downhil running determined reduced of PTI (~22.4%). Significant links between pain were obtained for both subjective pain perception tests starting at 24 and 48 hours, where the highest registered average happened in the step test after 48h, with high...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: Indirect dental composites may have adequate clinical performance. However, the literature is scarce regarding indirect composite resins and these solutions should be considered to maintain their properties. The aim of the study was to evaluate the influence of beverages, mouthwashes and bleaching agents on the hardness of indirect composite resins. Methods: Five different brands of indirect composite resins were evaluated: Adoro, Resilab, Cristobal, Sinfony and Epricord. Ten specimens of each brand were immersed in eleven different solutions: four mouthwashes (Listerine, Oral-B, Plax, Periogard), four beverages (coke soft drink, red wine, coffee, orange juice), three dental bleaching agents (16% peroxide of carbamide, 7.5% and 38% peroxide of hydrogen) and artificial saliva (control group). The Knoop hardness was measured before (baseline) and after 12, 24, 36 and 60 hours of immersion in mouthwashes; after 7, 14 and 21 days of immersion in beverages and after 7 and 14 days of immersion in dental bleaching agents. The results were analyzed using 3-way repeated measures ANOVA and Tukey’s test (p<0.05). Results: All resins presented significant decrease on hardness values after immersion process whereas this reduction was higher for Resilab and Sinfony. The latter exhibited the lowest initial values of hardness while Cristobol resin presented the highest hardness values. The mouthwashes promoted a significant decrease in the hardness of specimens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context: The possibility of bleaching vital teeth with peroxide-based products considerably revolutionized esthetic dentistry. Aim: The aim of this clinical study was to evaluate tooth color change and dental sensitivity after exposure to preloaded film containing a 10% hydrogen peroxide whitening system (Opalescence Trθswhite Supreme). Materials and Methods: A total of 13 volunteers, aged 18 to 25 years, participated in this study. The patients used the whitening system once a day for 60 minutes during the 8-day study. For maxillary incisors and canines, the color change was visually evaluated with the Vita color scale before, immediately, and six months after the treatment. Tooth sensitivity was evaluated during the daily gel applications. All whitening applications were done in office and under the supervision of a dental professional. Statistical Analysis Used: The results were analyzed using the Friedman Test (nonparametric repeated measures ANOVA) at a level of 5%, and Dunn's Multiple Comparison Test at the level of 5%. Results: It was verified that the original mean color values observed at the baseline analysis differed significantly from those observed immediately after bleaching, as well as from those seen in the analysis at six months ( P = 0.001). There was no significant difference between the mean color values observed in the immediate time and in the analysis at six months ( P = 0.474). No tooth sensitivity was observed in any patients. Conclusion: It was concluded that the bleaching technique using the 10% hydrogen peroxide system was effective in a short period of time without tooth sensitivity during applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)