575 resultados para prosthesis pigmentation
Resumo:
There have been numerous surgical techniques developed for removing the epulis fissuratum lesions in order to improve alveolar ridge contour and improving adaptation of full prostheses. Most of these techniques can cause postoperative complications, such as oedema, pain, difficulty in swallowing and jaw movements, haemorrhage, infections and slow placement of final prostheses. The use of carbon dioxide (CO2) laser for the surgical removal of epulis lesions has resulted in many significant improvements including convenient mucosa removal, no bleeding or need for sutures, and minimal postoperative pain and oedema. This study is of 15 cases of removal of extensive epulis with vestibuloplasty in the maxilla and mandible that was carried out with CO2 laser, with no postoperative complications, rapid healing, and excellent aesthetic and functional outcome, all of which allowed for more rapid placement of final prosthesis.
Resumo:
HMB-45, named for the immunogen used (human melanoma, black) is a monoclonal antibody developed 10 years ago by Gown and colleagues to a whole-cell extract of a human melanoma. Over the years, it has been demonstrated that HMB-45 is a highly sensitive and specific reagent for the identification of melanoma. More recently, it has been found that HMB-45 reacts with a protein designated gp100-cl, which is apparently related to the pmel 17 gene product. Because gp100-cl is a melanosomal matrix protein, HMB-45 is more correctly identified as an organelle-specific rather than tumor-specific reagent. HMB-45 immunoreactivity is seen in normal fetal and neonatal melanocytes but not in adult resting melanocytes. Reactive or proliferating melanocytes present in inflamed adult skin or in skin overlying certain dermal neoplasms, can also ''re-express'' the HMB-45-defined antigen. Whereas the vast majority of melanomas are HMB-45-positive, one important exception is desmoplastic malignant melanoma, which consistently demonstrates a much lower rate of expression of the HMB-45-defined antigen compared with other types of melanoma. In recent years there have been scattered reports of HMB-45 immunoreactivity in nonmelanomatous tumors, such as breast and other carcinomas, but virtually all these reports employed commercial ascites fluid preparations of HMB-45 antibody that were subsequently shown to be contaminated with nonspecific antibodies. Thus, for most practical purposes, a positive reaction with HMB-45 indicates active melanosome formation and, therefore, melanocytic differentiation. There is also a set of HMB-45-positive tumors that consistently manifest HMB-45 immunoreactivity but do not display obvious pigmentation: clear cell ''sugar'' tumor of the lung, angiomyolipoma, and lymphangiomyomatosis. Nonetheless, these lesions are all unified by recent ultrastructural studies that confirm the presence premelanosomes. Curiously, all three lesions also manifest evidence for simultaneous smooth-muscle differentiation. HMB-45 remains, therefore, a reliable marker of melanoma but may also provide insights into a rare group of tumors.
Resumo:
Radiative properties (reflectance rho, transmittance tau, and absorptance alpha) were determined for wavelengths from 300 to 850 nm in the haircoat and the skin of water buffalo, deer (Pantanal deer, Blastocerus dichotomus), and cattle of the Holstein, Simmental, Canchim, Brangus, and Nelore breeds. The results showed that white hairs have higher rho (0.60 to 0.67) than the other coat colors, but the gray coats (mixed white and dark hair) of the Nelore cattle presented higher rho than that of the white coats of the European breeds at wavelengths lower than 600 nm. The light gray colored skin of the Canchim cattle had higher rho (0. 66) than the non-pigmented skin of Holstein (0.53). Red skins presented rho values higher than those of dark gray and black skins. Buffalo skin (dark gray) presented an average rho of 0.23+/-0.02 and alpha of 0.77+/-0.02. The red haircoat of the deer presented rho lower (0.37) than that of cattle of the same color (0.58). However, there was little difference between deer and cattle with respect to reflectance and absorptance of the skin. As for the spectral transmittance of the skin, it was very low and about the same for both species, until 600 nm. In the range 600 to 850 nm, the tau values for cattle rose to 0. 17, while those for deer increased only to 0.12.
Resumo:
Acrylic resin denture teeth often exhibit rapid occlusal wear, which may lead to a loss of chewing efficiency and a loss of vertical dimension of occlusion. The use of metal occlusal surfaces on the acrylic resin denture teeth will minimize occlusal wear. Several articles have described methods to construct metal occlusal surfaces; however, these methods are time-consuming, costly, and sometimes considered to be unesthetic. These methods also require that the patient be without the prosthesis for the time necessary to perform the laboratory procedures. This article presents a quick, simple, and relatively inexpensive procedure for construction of composite occlusal surfaces on complete and partial dentures.
Resumo:
A novel method for surface profilometry by holography is presented. We used a diode laser emitting at many wavelengths simultaneously as the light source and a Bi12TiO20 (BTO) crystal as the holographic medium in single exposure processes. The employ of multi-wavelength, large free spectral range (FSR) lasers leads to holographic images covered of interference fringes corresponding to the contour lines of the studied surface. In order to obtain the relief of the studied surface, the fringe analysis was performed by the phase stepping technique (PST) and the phase unwrapping was carried out by the Cellular-automata method. We analysed the relief of a tilted flat metallic bar and a tooth prosthesis.
Resumo:
We report the simultaneous rehabilitation of an edentulous patient with a hybrid (zygomatic and conventional implants) all-on-four implant-supported prosthesis for the maxilla and a standard (conventional implants) all-on-four implant-supported prosthesis for the mandible. The transfer impression was made with a multifunctional guide and the upper and lower prostheses were placed 24 h postoperatively. Clinical and radiographic examinations showed no infection or bony resorption 2 years later. Simultaneous maxillary and mandibular rehabilitation with all-on-four immediate loading is a viable, fast and effective option for edentulous patients. (C) 2009 Published by Elsevier Ltd on behalf of The British Association of Oral and Maxillofacial Surgeons.
Resumo:
Facial injuries with the retention of foreign bodies inside the tissues, both in soft and hard ones, can cause major functional and aesthetic damage. Among the different etiological agents, cutting tools, fragments of a firearm, the splinter of wood, steel, or iron, launched by misuse, or even caused by defects in equipment, are the main cause of these injuries. The aim of this study was to discuss the peculiarity of the multidisciplinary approach in caring of a 33-year-old man, victim of an accident at work, by the rupture of an emery disc and consequent penetration of the fragments in violation of the tissues in the orbital and zygomatic region of the left side, with perforation of the eyeball and orbital-zygomatic fracture. Urgent treatment consisted of debridement of wounds, bleeding control, removal of foreign bodies, fracture reduction with rigid internal fixation, and suture, performed by the oral and maxillofacial surgical team. Reconstruction of orbital tissues by the ophthalmology team consisted of suture of the injuries. About 1 month after the trauma, phthisis bulbi was noted, and the patient underwent a new procedure under general anesthesia for eye evisceration and installation of an alloplastic prosthesis associated with the homogenous sclera. Facial harmony was restored, especially in aesthetics and function of the zygomatic-orbital complex.
Resumo:
The present investigation examined the extracutaneous pigmentation pattern of three species of anuran amphibians, Dendropsophus nanus, Physalaemus cuvieri, and Rhinella schneideri, during the course of their breeding seasons. Pigmentation intensity in the different organs was graded on a 4-category scale, in which category 0 refers to organs without pigment and category 3 refers to intensely pigmented organs, with 2 intermediate stages of progressively stronger pigmentation. Rhinella schneideri showed testicular pigmentation, with intra-specific variation (categories 0 and 1). In P. cuvieri the pigmentation in the lungs varied in time: all the animals showed pigmentation (category 1) at the beginning of the breeding season, and as the season progressed the absence of pigments became the most common pattern. In the liver of the first animals collected, the pigment intensity was high (category 2) with many iridophores present, but in the last specimens collected no iridophores were found. The variation in D. nanus occurred in the kidneys, where animals collected at the beginning of the season did not show pigmentation. Renal veins displayed few melanocytes (category 1); animals collected at the end of the season showed more pigmentation in the kidneys (category 2), whereas in the renal veins the intensity remained the same. The changes observed in the extracutaneous pigment system in some organs, during the reproductive period, may be due to physiological alterations or may represent a species-specific characteristic.
Resumo:
AimTo evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.Material and methodsForty SLActive Straumann (R) short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.ResultsTwo out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34 +/- 0.38 mm. After loading, the mean marginal bone loss was 0.23 +/- 0.33 and 0.21 +/- 0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2 +/- 9) and the 6-week evaluation (74.8 +/- 6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.ConclusionShort implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.To cite this article:Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study.Clin. Oral Impl. Res. 21, 2010; 937-943.doi: 10.1111/j.1600-0501.2010.01942.x.
Resumo:
The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.
Resumo:
The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.
Resumo:
This study assessed the oral health of individuals 60 years or older in the city of Araraquara, Sao Paulo, Brazil, in 1998. Of the 194 people who participated in the study, 91 of them were institutionalized and had an average age of 73.6 years, and 103 were not institutionalized and had an average age of 69.3 years. The study participants were examined by a previously trained oral surgeon who determined the prevalence of the most common oral health problems. The results revealed a large number of edentulous individuals (72% of those institutionalized and 60% of the noninstitutionalized participants) and many persons with extracted teeth (93% and 90%, respectively), as well as a high frequency of periodontal pockets (57% and 75%, respectively) and of inadequate dentures (80% and 61%, respectively). Our results show reduced quality of life for a large proportion of these older individuals, and also indicate that public health services should pay greater attention to this population group.
Resumo:
Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.
Resumo:
Utilization of contemporary post and core systems has facilitated the aesthetic restoration of endodontically treated teeth. Light transmission and biocompatibility have been enhanced by the introduction of metal-free post systems. The periodontal and endodontic status, root length, and histological structure of the devitalized teeth must be considered in order to achieve successful restoration following endodontic treatment. This article presents various restorative criteria for the aesthetic placement and buildup of post and core materials, as well as the preservation of maximum coronal and root structure.
Resumo:
Purpose: This investigation studied the effects of 3 surface treatments on the shear bond strength of a light-activated composite resin bonded to acrylic resin denture teeth. Materials and Methods: The occlusal surfaces of 30 acrylic resin denture teeth were ground flat with up to 400-grit silicon carbide paper. Three different surface treatments were evaluated: (1) the flat ground surfaces were primed with methyl methacrylate (MMA) monomer for 180 seconds; (2) light-cured adhesive resin was applied and light polymerized according to the manufacturer's instructions; and (3) treatment 1 followed by treatment 2. The composite resin was packed on the prepared surfaces using a split mold. The interface between tooth and composite was loaded at a cross-head speed of 0.5 mm/min until failure. Results: Analysis of variance indicated significant differences between the surface treatments. Results of mean comparisons using Tukey's test showed that significantly higher shear bond strengths were developed by bonding composite resin to the surfaces that were previously treated with MMA and then with the bonding agent when compared to the other treatments. Conclusion: Combined surface treatment of MMA monomer followed by application of light-cured adhesive resin provided the highest shear bond strength between composite resin and acrylic resin denture teeth.