377 resultados para Screw Extrusion


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report our achievements in the elaboration and optical characterizations of low-losses suspended core optical fibers elaborated from As2S3 glass. For preforms elaboration, alternatively to other processes like the stack and draw or extrusion, we use a process based on mechanical drilling. The drawing of these drilled performs into fibers allows reaching a suspended core geometry, in which a 2 μm diameter core is linked to the fiber clad region by three supporting struts. The different fibers that have been drawn show losses close to 0.9 dB/m at 1.55 μm. The suspended core waveguide geometry has also an efficient influence on the chromatic dispersion and allows its management. Indeed, the zero dispersion wavelength, which is around 5 μm in the bulk glass, is calculated to be shifted towards around 2μm in our suspended core fibers. In order to qualify their nonlinearity we have pumped them at 1.995 μm with the help of a fibered ns source. We have observed a strong non linear response with evidence of spontaneous Raman scattering and strong spectral broadening. © 2011 SPIE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A set of 12 samples of acid rock types Palmas (ATP) and Chapecó (ATC) was used to determine the chemical composition of plagioclase and pyroxene by electron microprobe, with the purpose to get information about the pressure and temperature of crystallization of these rocks. The results show that the pyroxene of ATP rocks (3,2 ± 1,2 kbar, max = 5,1 kbar and 1028 ± 38°C) were formed under pressure conditions higher than those ATC (1,8 ± 0,9 kbar, max = 3,4 kbar and 995 ± 26oC). However, the pressures obtained from plagioclase showed higher pressures for ATC (3.2 ± 1 kbar, max = 6,4 kbar and 1033 ± 12°C) than ATP (1,9 ± 1 kbar, max = 4,8 kbar and 1043 ± 5°C), suggesting that the crystallization of rocktype ATP began with the formation of pyroxene and plagioclase almost simultaneously at a depth of around 17 km while the ATC, began with the crystallization of plagioclase at a depth of about 21 km (assuming a gradient of 3,3 kbar/km). The geothermometry of plagioclase allow us to calculate the concentration of water from about 1 ± 0,3% H2O for both acid rock types. Additional calculations allow us to get the depth of water exsolution of magmatic liquid at 30m below the surface. Although the data are still preliminary and insufficient to model the extrusion of these rocks, they point out to an effusion mechanism of a partially fluidized magma by volatile, which would spread to large areas with small friction with the surface that would increased with the increase of viscosity caused by the loss of volatile and decreasing of temperature, developing coherent structures as lava flows.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work evaluated the effects of high moisture silage, extrusion and corn and sorghum drying with and without tannin, on the chemical composition and ruminal digestion of dry matter. The experimental design was completely randomized in 3x3 factorial scheme (kinds of grains: processing), for the chemical composition and degradability and three blocks (animals) through in situ method. It was verified significant difference between kinds of grains and processing in relation to the chemical composition, except for crude protein and mineral matter. The contents of etherextract in the three types of grains, were reduced significantly with the high moisture silage, extrusion and drying in relation to the humid material. For the contents of phenols, total and condensed tannin there was effect of hybrid, processing and interaction, and the most elevated contents were found in sorghum with tannin. Although grain composition has been similar, the interaction in ruminal ambient associated to the tannin, promoted differences in the dry matter degradability. It was concluded that sorghum without tannin may be ensiled or extruded, while the sorghum with tannin, must be extruded to improve the degradability and availability of nutrients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Bioactive glass and bioactive glass-ceramic cone implants were placed in the rabbit eviscerated socket to assess their biocompatibility. Methods: Fifty-one Norfolk albino rabbits underwent evisceration of the right eye followed by implantation of cones made from Bioglass® 45S5 (control group) and two types of bioactive glass-ceramic (Biosilicate®), a single- and a two-phase bioactive glass-ceramic implants into the scleral cavity. Postoperative reactions, animal behavior and socket conditions were monitored daily. Clinical exam, biochemical evaluations, and orbit computed tomographic scan were done at 7, 90, and 180 days post-procedure. After that, the animals were euthanized, and the orbital content was removed and prepared to light microscopy with morphometric evaluation and scanning electron microscopy examination. Statistical analysis was done by parametric and non-parametric analysis of variance, complemented by Dunn's and Tukey's tests (p<0.05). Results: All animals did not develop systemic toxicity throughout the experimental period and also did not have orbit infection, implant migration or extrusion. Morphological analysis demonstrated pseudocapsule around all implants. Bioglass® and single-phase Biosilicate® implants induced less inflammation and pseudocapsule formation than two-phase Biosilicate® cones. Seven days post-procedure, the inflammatory reaction was intense and gradually decreased throughout the experiment. Tissue reaction was least intense in animals receiving Bioglass® implants. Conclusions: We observe discrete differences among the studied materials, with best responses obtained with use of Bioglass® 45S5 and single-phase Biosilicate®. The authors agree these implants might be useful in the management of the anophthalmic socket. © 2012 Informa Healthcare USA, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The bone tissue responses to Cyanoacrylate have been described in the literature, but none used N-butyl-2-cyanoacrilate (NB-Cn) for bone graft fixation. Purpose: The aims of the study were: (a) to analyze the bone grafts volume maintenance fixed either with NB-Cn or titanium screw; (b) to assess the incorporation of onlay grafts on perforated recipient bed; and (c) the differences of expression level of tartrate-resistant acid phosphatase (TRAP) protein involved in bone resorption. Materials and Methods: Eighteen New Zealand White rabbits were submitted to calvaria onlay grafting on both sides of the mandible. On one side, the graft was fixed with NB-Cn, while on the other hand the bone graft was secured with an osteosynthesis screw. The computed tomography (CT) was performed just after surgery and at animals sacrifice, after 1 (n=9) and 6weeks (n=9), in order to estimate the bone grafts volume along the experiments. Histological sections of the grafted areas were prepared to evaluate the healing of bone grafts and to assess the expression of TRAP protein. Results: The CT scan showed better volume maintenance of bone grafts fixed with NB-Cn (p≤0.05) compared with those fixed with screws, in both experimental times (analysis of variance). The immunohistochemical evaluation showed that the TRAP expression in a 6-week period was significantly higher compared with the 1-week period, without showing significant difference between the groups (Wilcoxon and Mann-Whitney). Histological analysis revealed that the NB-Cn caused periosteum damage, but provided bone graft stabilization and incorporation similar to the control group. Conclusion: The perforation provided by screw insertion into the graft during fixation may have triggered early revascularization and remodeling to render increased volume loss compared with the experimental group. These results indicate that the NB-Cn possesses equivalent properties to titanium screw to be used as bone fixation material in osteosynthesis. © 2010 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the majority of cases of bone fracture requiring surgery, orthopedic implants (screw-plate and screw) are used for osteosynthesis and the infections associated with such implants are due to the growth of microorganisms in biofilms. The objective of this study was to identify microorganisms recovered from osteosynthesis implants used to fix bone fractures, to assess the viability of the cells and the ability of staphylococci to adhere to a substrate and to determine their sensitivity/resistance to antimicrobials. After surgical removal, the metal parts of austenitic stainless steel (ASTM F138/F139 or ISO NBR 5832-1/9) were transported to the Laboratory of Clinical Microbiology, washed in buffer and subjected to ultrasonic bath at 40±2 kHz for 5 minutes. The sonicated fluid was used to seed solid culture media and cell viability was assessed under the microscope by with the aid of a fluorescent marker. The production of extracellular polysaccharide by Staphylococcus spp. was investigated by means of adhesion to a polystyrene plate. The profile of susceptibility to antimicrobials was determined by the disk diffusion assay. The most frequently isolated bacteria included coagulase-negative Staphylococcus resistant to erythromycin, clindamycin and oxacillin. Less frequent were Pseudomonas aeruginosa resistant to trimethoprim/sulfamethoxazole and ampicillin, Acinetobacter baumannii resistant to ceftazidime, Enterobacter cloacae resistant to cephalothin, cefoxitin, cefazolin, levofloxacin and ciprofloxacin, Bacillus spp. and Candida tropicalis. The observation of slides by fluorescence microscope showed clusters of living cells embedded in a transparent matrix. The test for adherence of coagulase-negative Staphylococcus to a polystyrene plate showed that these microorganisms produce extracellular polysaccharide. In conclusion, the metal parts were colonized by bacteria related to orthopedic implant infection, which were resistant to multiple antibiotics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Biological and mechanical implant-abutment connection complications and failures are still present in clinical practice, frequently compromising oral function. The purpose of this study was to evaluate the reliability and failure modes of anterior single-unit restorations in internal conical interface (ICI) implants using step-stress accelerated life testing (SSALT). Materials and methods: Forty-two ICI implants were distributed in two groups (n = 21 each): group AT-OsseoSpeed™ TX (Astra Tech, Waltham, MA, USA); group SV-Duocon System Line, Morse Taper (Signo Vinces Ltda., Campo Largo, PR, Brazil). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to SSALT in water. Use-level probability Weibull curves and reliability for a mission of 50,000 cycles at 200 N were calculated. Differences between groups were assessed by Kruskal-Wallis along with Bonferroni's post-hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value derived from use level probability Weibull calculation was 1.62 (1.01-2.58) for group AT and 2.56 (1.76-3.74) for group SV, indicating that fatigue was an accelerating factor for failure of both groups. The reliability for group AT was 0.95 and for group SV was 0.88. Kruskal-Wallis along with Bonferroni's post-hoc tests showed no significant difference between the groups tested (P > 0.27). In all specimens of both groups, the chief failure mode was abutment fracture at the conical joint region and screw fracture at neck's region. Conclusions: Reliability was not different between investigated ICI connections supporting maxillary incisor crowns. Failure modes were similar. © 2012 John Wiley & Sons A/S.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metallic biomaterials are used to reinforce or to restore the form and function of hard tissues. Implants and prosthesis are used to replace shoulders, knees, hips and teeth. When these materials are inserted in bone several biological reactions happen. This process can be associated to surface properties (topography, roughness and surface energy). In this work, the influence of biomimetic surface treatment in the osseointegration of Ti-30Ta dental implants was evaluated. Ingots were obtained from titanium and tantalum by using an arc-melting furnace. They were submitted to heat treatment at 1,100°C for 1 h, cooled in water and cold worked by swaging. Then, screw-shaped implants (2.0 mm diameter by 2.5 mm length) were manufactured and they were implanted in a rat's femur. Animals were divided into two groups: untreated (control group) and treated (biomimetic surface treatment). They were sacrificed 30 days after implantation. For histological analysis, implants with surrounding tissue were removed and immersed in formaldehyde. Samples were embedded in polymethyl methacrylate and after polymerization, cut with a saw, polished and mounted on glass slides. The results obtained suggest that biomimetic surface treatment was able to promote an increase osseointegration on the surface of dental implants. © Springer-Verlag Berlin Heidelberg 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent studies have evaluated many methods of internal fixation for sagittal split ramus osteotomy (SSRO), aiming to increase stability of the bone segments while minimizing condylar displacement. The purpose of this study was to evaluate, through biomechanical testing, the stability of the fixation comparing a specially designed bone plate to other two commonly used methods. Thirty hemimandibles were separated into three equal groups. All specimens received SSRO. In Group I the osteotomies were fixed with three 15 mm bicortical positional screws in an inverted-L pattern with an insertion angle of 90°. In Group II, fixation was carried out with a four-hole straight plate and four 6 mm monocortical screws. In Group III, fixation was performed with an adjustable sagittal plate and eight 6 mm monocortical screws. Hemimandibles were submitted to vertical compressive loads, by a mechanical testing unit. Averages and standard deviations were submitted to analysis of variance using the Tukey test with a 5% level of significance. Bicortical screws presented the greatest values of loading resistance. The adjustable miniplate demonstrated 60% lower resistance compared to bicortical screws. Group II presented on average 40% less resistant to the axial loading. © 2012 International Association of Oral and Maxillofacial Surgeons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking reconstruction plate in the fixation of atrophic mandible fractures. Polyurethane mandibles with a simulated linear fracture at the midline were used as substratum. Results show that resistance of the fixation is poor when one and two screws are used on each side of the fracture. Three screws on each side of the fracture significantly increases the resistance to displacement. However, no additional strength is added to the construct when more than three screws per side are used. © 2013 International Association of Oral and Maxillofacial Surgeons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of exogenous enzymes supplementation on kibble diets for dogs formulated with soybean meal (SBM) as a substitute for poultry by-product meal (PM) was investigated on nutrient digestibility, fermentation products formation, post-prandial urea response and selected faecal bacteria counts. Two kibble diets with similar compositions were used in two trials: PM-based diet (28.9% of PM; soybean hulls as a fibre source) and SBM-based diet (29.9% of SBM). In experiment 1, the SBM diet was divided into three diets: SBM-0, without enzyme addition; SBM-1, covered after extrusion with 7500U protease/kg and 45U cellulase/kg; and SBM-2, covered with 15000U protease/kg and 90U cellulase/kg. In experiment 2, the SBM diet was divided into three diets: SBM-0; SBM-1, covered with 140U protease/kg; 8U cellulase/kg, 800U pectinase/kg, 60U phytase/kg, 40U betaglucanase/kg and 20U xylanase/kg; and SMB-2, covered with 700U protease/kg, 40U cellulase/kg, 4000U pectinase/kg, 300U phytase/kg, 200U betaglucanase/kg and 100U xylanase/kg. Each experiment followed a block design with six dogs per diet. Data were submitted to analysis of variance and means compared by orthogonal and polynomial contrasts (p<0.05). In both experiments, nutrients and energy digestibility did not differ between diets (p>0.05). SBM consumption resulted in increased faecal moisture and production (p<0.05), without effect on faecal score. Higher concentration of propionate, acetate and lactate, and lower ammonia and pH were found in the faeces of dogs fed SBM (p<0.05). Higher post-prandial urea was verified in dogs fed SBM (p<0.05). In experiment 2, the addition of enzymes increased faecal concentration of propionate, acetate and total short-chain fatty acid (p<0.05) and tended to reduce post-prandial urea concentration (p=0.06). Although with similar digestibility, SBM shows a worse utilization of absorbed amino acids than the PM. Soybean oligosaccharides can beneficially change gut fermentation product formation. Enzymes can increase the gut fermentation activity and improve the SBM proteic value. © 2013 Blackwell Verlag GmbH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, there is an interest in technologies that favour the use of coproducts for animal nutrition. The effect of adding two enzyme mixtures in diets for dogs formulated with wheat bran (WB) was evaluated. Two foods with similar compositions were formulated: negative control (NC; without WB) and test diet (25% of WB). The test diet was divided into four treatments: without enzyme (positive control), enzyme mixture 1 (ENZ1; added before extrusion β-glucanase, xylanase, cellulase, glucoamylase, phytase); enzyme mixture 2 (ENZ2; added before extrusion the ENZ1 more α-amylase); enzyme mixture 2 added after the extrusion (ENZ2ex). ENZ1 and ENZ2 were used to evaluate the enzyme effect on extruder pre-conditioner (processing additive) and ENZ2ex to evaluate the effect of enzyme supplementation for the animal. Digestibility was measured through total collection of faeces and urine. The experiment followed a randomized block design with five treatments (diets) and six dogs per diet, totalling 30 dogs (7.0 ± 1.2 years old and 11.0 ± 2.2 kg of body weight). Data were submitted to analysis of variance and means compared by Tukey's test and orthogonal contrasts (p < 0.05). Reducing sugars showed an important reduction after extrusion, suggesting the formation of carbohydrate complexes. The apparent total tract digestibility (ATTD) of dry matter, organic matter, crude protein, acid-hydrolysed fat and energy was higher in NC than in diets with WB (p < 0.001), without effects of enzyme additions. WB diets resulted in higher faecal production and concentration of short-chain fatty acids (SCFA) and reduced pH and ammonia concentration (p < 0.01), with no effect of enzyme addition. The enzyme addition did not result in improved digestibility of a diet high in non-starch polysaccharides; however, only ATTD was measured and nutrient fermentation in the large intestine may have interfered with the results obtained. WB modified fermentation product formation in the colon of dogs. © 2013 Blackwell Verlag GmbH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The retaining screw of the implant-supported dental prosthesis is the weakest point of the crown/implant system. Furthermore, crown height is another important factor that may increase the lever arm. Therefore, the aim of this study was to assess the stress distribution in implant prosthetic screws with different heights of the clinical crown of the prosthesis using the method of three-dimensional finite element analysis. Three models were created with implants (3.75 mm × 10 mm) and crowns (heights of 10, 12.5 and 15 mm). The results were visualised by means of von Mises stress maps that increased the crown heights. The screw structure exhibited higher levels of stresses in the oblique load. The oblique loading resulted in higher stress concentration when compared with the axial loading. It is concluded that the increase of the crown was damaging to the stress distribution on the screw, mainly in oblique loading. © 2013 Taylor & Francis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate and compare the biocompatibility of two types of Ferrara intracorneal ring segment: with and without chondroitin sulfate coating by clinical and histopathological evaluation. METHODS: A randomized experimental study was carried out on thirty right-eye corneas from 30 Norfolk albino rabbits allocated into two experimental groups: Group G1 - implanted with Ferrara intracorneal ring segment without coating (FICRS) and Group G2 - implanted with Ferrara intracorneal ring segment with chondroitin sulfate coating (FICRS-CS). Left eyes formed the control group. Clinical parameters analyzed were: presence of edema, vascularization, infection and ring extrusion one, 30, and 60 days after surgery. Histopathological parameters analyzed were: number of corneal epithelial layers over and adjacent to the ring, presence of spongiosis, hydropic degeneration, basement membrane thinning, inflammatory cells, neovascularization and pseudocapsule formation. RESULTS: At clinical examination 60 days after implant, edema, vascularization and extrusion were observed respectively in 20%, 26.7%, 6.7% of FICRS corneas and in 6.7%, 6.7%, and 0% of FICRS-CS corneas. Histopathological evaluation showed epithelial-layer reduction from 5 (5;6) to 3 (3;3) with FICRS and from 5 (5;5) to 4 (3;5) with FICRS-CS in the region over the ring. Epithelial spongiosis, hydropic degeneration, and basement membrane thinning were present in 69.2%, 53.8%, and 69.2% of FICRS and in 73.3%, 73.3%, and 46.7% with FICRS-CS, respectively. Vascularization was present in 38.5% of FICRS and 13.3% with FICRS-CS, inflammatory cells in 75% of FICRS and 33.3% with FICRS-CS, and pseudocapsule in 66.7% of FICRS and 93.3% with FICRS-CS. Giant cells occurred only in the FICRS-CS group (20%). CONCLUSION: Ferrara intracorneal rings coated with chondroitin sulfate (FICRS-CS) caused lower frequency of clinical and histopathological alterations than Ferrara intracorneal rings without the coating (FICRS), demonstrating higher biocompatibility of the FICRS-CS.