288 resultados para Wolf (Steamship)
Resumo:
Laryngeal Electromyography (LEMG) is a diagnostic test commonly used in patients with vocal fold movement disorder The aim of this study is to describe LEMG in patients with vocalfold immobility. A total of 55 dysphonic patients with vocal fold immobility diagnosed by laryngeal endoscopy were grouped according to probable clinical cause: 1) unknown; 2) traumatic; or 3) tumoral compression. They were submitted to LEMG by percutaneous insertion of concentric needle electrode. LEMG was conclusive in all patients and showed a majority with peripheral nerve injury. LEMG diagnosed peripheral nerve damage in 25 group 1, 12 group 2, and 11 group 3 patients. LEMG was normal in 4 patients, suggesting cricoarytenoid joint fixation. Central nervous system disorders was suggested in 2 and myopathic pattern in 1. As the major cause of vocal fold immobility is peripheral nerve damage, LEMG is an important test to confirm diagnosis.
Resumo:
Use of serological tests in the diagnosis of infectious diseases in wild animals has several limitations, primarily the difficulty of obtaining species-specific reagents. Wild canids, such as maned wolves (Chrysocyon brachyurus), are highly predisposed to infection by Toxoplasma gondii and, to a lesser extent, to Neospora caninum. The aim of the present study was to evaluate homologous, heterologous, and affinity conjugates in enzyme-linked immunosorbent assays (ELISAs) and indirect fluorescent antibody tests (IFATs) for detecting immunoglobulin (Ig) G antibodies against T. gondii and N. caninum in maned wolves. Serum samples were obtained from 59 captive animals in Brazil and tested by ELISA for T. gondii serology and IFAT for N. caninum serology using 3 different enzymatic and fluorescent conjugates: homologous (guinea pig anti-maned wolf IgG-peroxidase and -fluorescein isothiocyanate [FITC]), heterologous (rabbit anti-dog IgG-peroxidase and -FITC), and affinity (protein A-peroxidase and -FITC). Seropositivity to T. gondii was comparable among the homologous (69.5%), heterologous (74.6%), and affinity (71.2%) enzymatic conjugates. A significant positive correlation was found between the antibody levels determined by the 3 enzymatic conjugates. The highest mean antibody levels (ELISA index = 4.5) were observed with the protein A-peroxidase conjugate. The same seropositivity to N. caninum (8.5%) was found with the homologous and heterologous fluorescent conjugates, but protein A-FITC was not able to detect or confirm any positive samples with homologous or heterologous conjugates. Our results demonstrate that homologous, heterologous, and affinity conjugates might be used in ELISA for serological assays of T. gondii in wild canids, whereas for N. caninum infection, only the homologous or heterologous fluorescent conjugates have been shown to be useful. © American Society of Parasitologists 2005.
Resumo:
The objective of this work is to introduce and demonstrate the technical feasibility of the continuous flash fermentation for the production of butanol. The evaluation was carried out through mathematical modeling and computer simulation which is a good approach in such a process development stage. The process consists of three interconnected units, as follows: the fermentor, the cell retention system (tangential microfiltration) and the vacuum flash vessel (responsible for the continuous recovery of butanol from the broth). The efficiency of this process was experimentally validated for the ethanol fermentation, whose main results are also shown. With the proposed design the concentration of butanol in the fermentor was lowered from 11.3 to 7.8 g/l, which represented a significant reduction in the inhibitory effect. As a result, the final concentration of butanol was 28.2 g/l for a broth with 140 g/l of glucose. Solvents productivity and yield were, respectively, 11.7 g/l.h and 33.5 % for a sugar conversion of 95.6 %. Positive aspects about the flash fermentation process are the solvents productivity, the use of concentrated sugar solution and the final butanol concentration. The last two features can be responsible for a meaningful reduction in the distillation costs and result in environmental benefits due to lower quantities of wastewater generated by the process. © 2008 Berkeley Electronic Press. All rights reserved.
Resumo:
We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/. c to 1 TeV/. c. The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.), independent of the muon momentum, below 100 GeV/. c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. © 2010.
Resumo:
A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS experiment uses self-triggering arrays of drift tubes in the barrel muon trigger to perform the identification of the correct bunch crossing. The identification is unique only if the trigger chain is correctly synchronized. In this paper, the synchronization performed during an extended cosmic ray run is described and the results are reported. The random arrival time of cosmic ray muons allowed several synchronization aspects to be studied and a simple method for the fine synchronization of the Drift Tube Local Trigger at LHC to be developed. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS High-Level Trigger (HLT) is responsible for ensuring that data samples with potentially interesting events are recorded with high efficiency and good quality. This paper gives an overview of the HLT and focuses on its commissioning using cosmic rays. The selection of triggers that were deployed is presented and the online grouping of triggered events into streams and primary datasets is discussed. Tools for online and offline data quality monitoring for the HLT are described, and the operational performance of the muon HLT algorithms is reviewed. The average time taken for the HLT selection and its dependence on detector and operating conditions are presented. The HLT performed reliably and helped provide a large dataset. This dataset has proven to be invaluable for understanding the performance of the trigger and the CMS experiment as a whole. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS Collaboration conducted a month-long data taking exercise, the Cosmic Run At Four Tesla, during October-November 2008, with the goal of commissioning the experiment for extended operation. With all installed detector systems participating, CMS recorded 270 million cosmic ray events with the solenoid at a magnetic field strength of 3.8 T. This paper describes the data flow from the detector through the various online and offline computing systems, as well as the workflows used for recording the data, for aligning and calibrating the detector, and for analysis of the data. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance. © 2010 IOP Publishing Ltd and SISSA.
Resumo:
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented. © 2010 IOP Publishing Ltd and SISSA.