207 resultados para Prótese sobre implantes


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design of implant structure is still a questioning to the professionals, while their variations can to influence of stress distribution favorably to bone. Therefore, the aim of study was to review addressing the topic of osseointegrated implants design establishing answers for the patient oral rehabilitation, according variations existing on the market. It was conducted a detailed search strategy by the PubMed/ Medline and Bireme, it was used as descriptors: “dental implants cylinder”; “dental implants thread”; “dental implants geometry”, until May 2014. From 798 articles, after review were selected 18 articles and 1 specific area book. The results were divided to compare design of implant and threads for further discussion and conclusions. Thus, conclude that the threads implants are best used because of its advantages with respect to the stress distribution and stability primary. The variations of the differents types of threads, have influence for stress distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increased prevalence of diabetic individuals has become a public health problem. Diabetes Mellitus is a metabolic disorder characterized by an increase in plasma glucose levels. It impairs the physiological equilibrium in utilization of carbohydrate by tissues. The persistent hyperglycemia can produce deleterious effects on bone formation due the microvascular complication. The present paper reviews the bibliography linking the impact of glycemic control at complications associated at diabetes mellitus on osseointegration. In experimental models of diabetes it was observed a reduced level of bone-implant contact. This failure can be reduced by means of hyperglycemia control. Also, several studies point the beneficial effect of coated implant on osseointegration process. It is necessary to take special care into account for the placement of implants in diabetic patient and improve the percentages of implant survival. A rigorous control of plasma glycaemia, together with other measures, like as absence of chronic complications, good oral hygiene and regular medical follow-up has been related to rising the percentages of successful in diabetic patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Removable partial denture improve functional and aesthetic failures caused by partial loss of teeth, however specific characteristics of each patients can determine the success of treatment, especially with regard to the support of the prosthesis, which may depend on teeth, the combination of teehe and mucosa and currently associated with the dental implants. The aim of this study is report a case in which there was the need of the association, to enable better aesthetics and self-esteem to the patients. After implant placement and fabrication of prosthetic patient reported satisfaction with the rehabilitation treatment, improving their quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study used 12 photoelastics models with different height and thickness to evaluate if the axial loading of 100N on implants changes the morphology of the photoelastic reflection. Methods: For the photoelastic analysis, the models were placed in a reflection polariscope for observation of the isochromatic fringes patterns. The formation of these fringes resulted from an axial load of 100N applied to the midpoint of the healing abutment attached to the implant with 10.0mm x 3.75mm (Conexão, Sistemas de Próteses, Brazil). The tension in each photoelastic model was monitored, photographed and observed using the software Phothoshop 7.0. For qualitative analysis, the area under the implant apex was measured including the green band of the second order fringe of each model using the software Image Tool. After comparison of the areas, the performance generated by each specimen was defined regarding the axial loading. Results: There were alterations in area with different height and thickness of the photoelastic models. It was observed that the group III (30mm in height) presented the smallest area. Conclusion: There was variation in the size of the areas analyzed for different height and thickness of the models and the morphology of the replica may directly influence the result in researches with photoelastic models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The maxillofacial prosthetic rehabilitation aims of individuals with craniofacial deformities resulting from trauma, congenital malformations or tumors. Many researches have been done to improve the stability and retention of dentures in patients. With the advent of osseointegration, the maxillofacial prosthesis suffered a major advance making possible the realization of prosthetic works with stability, aesthetic quality and predictable results. This paper reviews the literature regarding the use of zygomatic implants in the fixation of maxillofacial prostheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Morse Taper implant system, developed from its introduction in engineering, has become increasingly effective for use in dentistry. However, other systems, main external hexagon type, have been used more frequently today. Current studies have been reported the positive features of the Morse taper system and even emphasized as ideal within the systems used in implantology. Unfortunately, some professional duty by not knowing this system, or even prefer hexagon type system by decreased cost of components, have refused to use it. Thus, this study was aimed to perform a brief review of the Morse taper system, emphasizing its main points of interest in dentistry, in an attempt to familiarize the professionals to at least learn more about this system that has the prospect to become the leading system implants used in dentistry in the coming years. It is concluded that this system of dental implants is favorable showing predictability and success.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: o tratamento com implantes dentários para a reposição de dentes na região estética exige a utilização de materiais e técnicas que permitam o máximo de naturalidade entre a restauração, os dentes vizinhos e o tecido gengival. Dessa forma, torna-se necessário criar o correto perfil de emergência para o dente, assim como a utilização de materiais com alto potencial estético. Objetivo: o objetivo do presente trabalho foi ilustrar, através de um caso clínico, a utilização de uma técnica de moldagem para a correta cópia do perfil de emergência do dente e sua transferência para o modelo de trabalho, tornando possível a confecção de uma restauração totalmente cerâmica, perfeitamente integrada ao tecido gengival. Caso clínico: paciente de 30 anos, procurou o clínica de prótese dentária com desejo de melhorar a estética dos dentes. Após diagnóstico e planejamento, foram confeccionadas 2 coroas totalmente cerâmicas sobre os dentes 12 e 21, e confecção de 1 coroa cerâmica sobre um pilar de zircônia após o estabelecimento e registro do perfil de emergência do dente 11. Conclusão: após a conclusão do tratamento, observou-se naturalidade, estética e perfeita integração entre as restaurações, os dentes remanescentes e o tecido gengival.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The obstructive sleep apnea syndrome affects millions of people around the world. The mandibular repositioning devices have been indicated in cases of mild/moderate syndrome; however in edentulous patients its use is deficient since there is no retention. Therefore the objective of this study was to conduct a review on the use of this treatment method combined to osseointegrated implants. A search on the theme: Dental implant and sleep apnea syndromewas performed in the Medline/PubMed, ISI, Cochrane, Dentistry Oral Science, Clinical Trials, Controlled Trials, and Bireme-BvS, databases, and 22 articles were found. After anevaluation 2 studies were selected and the review was complemented with an analysis of randomized controlled trials in the previous seven bases using the key-words: Sleep apnea syndrome, Oral appliance and Randomized controlled trial. The search returned 37 articles, and after they were submitted to inclusion criteria 17 studies were selected. There are a small number of studies presenting the use of dental implants as a mean to assist the stabilization of the mandibular repositioning appliances; those that are available are case reports that focusing on the effectiveness of the technique. Studies examining the effect these appliances in dentate patients indicate improvement in the levels of apnea and snoring. The use of mandibular repositioning appliances in dentate patients is an effective technique in treatment of patients with obstructive sleep apnea syndrome mild/moderate. Randomized controlled trialsare required in order to enable an analysis of the use of mandibular repositioning devices with the aid of dental implants .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present article describes the treatment planning and fabrication of overlay denture to restore the jaw relationship in a partial edentulous patient with bruxism. A male patient, 51 years old, was referred to the oral rehabilitation clinic complaining about the chewing and aesthetic. The occlusal surface of the superior teeth presented severe wear. The fabrication of an interim overlay denture to restore the jaw relationship was planned. The overlay had metallic projections and covered the occlusal surface of superior teeth. After overlay insertion both function and aesthetic of the patient were recovered. It was concluded that the use of overlay improved the physiological normal position of the jaw and could provide a favorable prognosis for a definitive oral rehabilitation with implant-supported fixed denture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concept of switching platform is the use of an implant by platform wider than the abutment. Recently, researches have shown that this type of dental implant design tends to offer a higher preservation of crestal bone when compared to the traditional pattern of bone loss. The present study aims to perform a critical review on the switching platform concept establishing possible advantages of the technique. A search was performed on Medline/Pubmed about the topic “dental implant” and “platform switching”, and after applying inclusion criteria 40 studies were selected. The literature on longevity present prospective studies that show less bone loss, studies in biomechanics exhibit better or similar stress distribution around the bone crest, however, is not yet defined the role of the biological width. Thus, studies of longevity, and randomized prospective studies are of a great relevance to be performed in order to confirm the benefits of this technique and to establish a protocol indication. It is possible, based on this literature review, to conclude that longitudinal and randomized studies show that the platform switching implants have longevity and less bone loss. Biomechanically, the technique is possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this revision was to explore the concept of Platform Switching in implantology and its acting in the clinical practice. The concept of platform switching will be considered together with a revision of pertinent literature, with the purpose of providing guidelines based on scientific evidences. The following databases were used: Pubmed, Library Cochrane and ISI in the last 17 years. The inclusion approaches were: clinical articles, laboratorials and of revision on the topic, in English language. 41 articles were selected, using the describers "platform switching dental implants", "platform shifting and dental implants", "expanded platform dental implant". In accordance with this revision, implant them platform switching they present a rate of more favorable bony remodeling that you implant them conventional. This fact seems to be resulting of a group of biological factors and mechanics. The concept of platform switching has important relevance in the aesthetic area.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Titanium dental implants have been common practice in the dental office, which can increases the number of allergic reactions to this material. Objectives: to alert dental surgeons and specialists of this possible phenomenon through a literature review. Material and methods: an electronic search at PubMed was performed with the keywords “dental implants”, “titanium”, and “allergy” from January 1990 to May 2013. Only articles published in the English language were included. Letters to editor were excluded. Results: from the 22 initially retrieved articles, only 7 were included, being 4 clinical case reports and 3 experimental studies. For clinical cases, the reactions included edema, erythema, exfoliative cheilitis, and eczema. Regarding experimental studies, skin rash and dermatitis were reported. A patch test was not used in two clinical reports. Only one study used histological analysis to attest the lack of allergic reactions. Conclusion: within the limits of the available literature, allergic reactions to titanium dental implants are extremely rare and seem to be related to the female gender. More controlled clinical studies are necessary to elucidate this question.