310 resultados para Maned wolf


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to propose a simple and efficient mechanism to deal with the problem of executing sequential code in a pure dataflow machine. Our results is obtained with a simulator of Wolf [4] architecture. The implemented mechanism improved the architecture performance when executing sequential code and we expect that this improvement could be better if we use some heuristics to deal with some special groups of instructions such as branch operations. Further research will show us if this is true.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quantitative analysis of normal values of motor unit action potentials duration and amplitude of muscles tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL), and cricoaritenoideus posterioris (CAP) was performed in 14 adult normal Brazilian volunteers. The recordings were obtained by percutaneously inserted concentric needle electrode. Different motor unit action potentials were manually selected in each muscle for quantitative computerized analysis of duration and amplitude. The mean values for duration and amplitude were respectively 3.8 ms and 413 μV for TA, 4.9 ms and 585 μV for CT, 4.1 ms and 388 μV for CAL and 4.5 ms and 475 μV in CAP. There were no similar reports of normal values of motor unit action potentials in Brazilian subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laryngeal Electromyography (LEMG) is an auxiliary diagnostic method used for the comprehension and diagnosis of different neurological diseases that compromise laryngeal function. The most common LEMG technique is the percutaneous insertion of needle electrodes guided by surface anatomical references. We describe techniques for inserting needle electrodes into the tireoaritenoideus (TA), cricotireoideus (CT), cricoaritenoideus lateralis (CAL) and cricoaritenoideus posterioris (CAP) muscles; these are used at UNICAMP laryngology ambulatory; we discuss difficulties found and their proposed solutions. All patients were submitted to otorhinolaryngological, phonoaudiological and laryngeal endoscopy before LEMG. The CAP approach, by digital rotation of the thyroid cartilage was found to be the most difficult, followed by the CAL approach. TA and CT approaches gave no major problems, except with some older and obese patients. A significant complication of the TA approach via thyroid cartilage was a hematoma in one patient which partially obstructed the laryngeal lumen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes preliminary laryngeal electromyography (LEMG) data and botulinum toxin treatment in patients with dysphonia due to movement disorders. Twenty-five patients who had been clinically selected for botulinum toxin administration were examined, 19 with suspected laryngeal dystonia or spasmodic dysphonia (SD), 5 with vocal tremor, and 1 with Gilles de la Tourette syndrome (GTS). LEMG evaluations were performed before botulinum toxin administration using monopolar electrodes. Electromyography was consistent with dystonia in 14 patients and normal in 5, and differences in frequency suggesting essential tremor in 3 and Parkinson tremors in 2. The different LEMG patterns and significant improvement in our patients from botulinum toxin therapy has led us to perform laryngeal electromyography as a routine in UNICAMP movement disorders ambulatory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laryngeal Electromyography (LEMG) is a diagnostic test commonly used in patients with vocal fold movement disorder The aim of this study is to describe LEMG in patients with vocalfold immobility. A total of 55 dysphonic patients with vocal fold immobility diagnosed by laryngeal endoscopy were grouped according to probable clinical cause: 1) unknown; 2) traumatic; or 3) tumoral compression. They were submitted to LEMG by percutaneous insertion of concentric needle electrode. LEMG was conclusive in all patients and showed a majority with peripheral nerve injury. LEMG diagnosed peripheral nerve damage in 25 group 1, 12 group 2, and 11 group 3 patients. LEMG was normal in 4 patients, suggesting cricoarytenoid joint fixation. Central nervous system disorders was suggested in 2 and myopathic pattern in 1. As the major cause of vocal fold immobility is peripheral nerve damage, LEMG is an important test to confirm diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this work is to introduce and demonstrate the technical feasibility of the continuous flash fermentation for the production of butanol. The evaluation was carried out through mathematical modeling and computer simulation which is a good approach in such a process development stage. The process consists of three interconnected units, as follows: the fermentor, the cell retention system (tangential microfiltration) and the vacuum flash vessel (responsible for the continuous recovery of butanol from the broth). The efficiency of this process was experimentally validated for the ethanol fermentation, whose main results are also shown. With the proposed design the concentration of butanol in the fermentor was lowered from 11.3 to 7.8 g/l, which represented a significant reduction in the inhibitory effect. As a result, the final concentration of butanol was 28.2 g/l for a broth with 140 g/l of glucose. Solvents productivity and yield were, respectively, 11.7 g/l.h and 33.5 % for a sugar conversion of 95.6 %. Positive aspects about the flash fermentation process are the solvents productivity, the use of concentrated sugar solution and the final butanol concentration. The last two features can be responsible for a meaningful reduction in the distillation costs and result in environmental benefits due to lower quantities of wastewater generated by the process. © 2008 Berkeley Electronic Press. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/. c to 1 TeV/. c. The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.), independent of the muon momentum, below 100 GeV/. c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. © 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A large sample of cosmic ray events collected by the CMS detector is exploited to measure the specific energy loss of muons in the lead tungstate (PbWO4) of the electromagnetic calorimeter. The measurement spans a momentum range from 5 GeV/c to 1 TeV/c. The results are consistent with the expectations over the entire range. The calorimeter energy scale, set with 120 GeV/c electrons, is validated down to the sub-GeV region using energy deposits, of order 100 MeV, associated with low-momentum muons. The muon critical energy in PbWO4 is measured to be 160+5 -68 GeV, in agreement with expectations. This is the first experimental determination of muon critical energy. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS Collaboration conducted a month-long data-taking exercise known as the Cosmic Run At Four Tesla in late 2008 in order to complete the commissioning of the experiment for extended operation. The operational lessons resulting from this exercise were addressed in the subsequent shutdown to better prepare CMS for LHC beams in 2009. The cosmic data collected have been invaluable to study the performance of the detectors, to commission the alignment and calibration techniques, and to make several cosmic ray measurements. The experimental setup, conditions, and principal achievements from this data-taking exercise are described along with a review of the preceding integration activities. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were executed, and the trigger synchronisation. Using data from extended cosmic ray runs, the muon, electron/photon, and jet triggers have been validated, and their performance evaluated. Efficiencies were found to be high, resolutions were found to be good, and rates as expected. © 2010 IOP Publishing Ltd and SISSA.