247 resultados para IMPLANT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the presence or absence of adjacent teeth on the level of the mesial and distal alveolar bony crest following healing at sites where implants were installed immediately into extraction sockets. Material and methods: Six Labrador dogs were used. In the right side of the mandible, full-thickness flaps were elevated, and the second, third, and fourth premolars and first molars were extracted. In the left side of the mandible, endodontic treatments of the mesial roots of the third and fourth premolars as well as of the first molars were performed. Full-thickness flaps were elevated, the teeth were hemi-sected, and the distal roots were removed. The second premolars were extracted as well. Subsequently, implants were bilaterally installed with the implant shoulder flush with the buccal bony crest. Implants were placed in the center of the alveoli, but at the fourth premolars, they were placed toward the lingual bony plate of the alveoli. After 3 months of healing, the animals were euthanized and histological sections of the sites prepared. Results: Larger bony crest resorption was observed at the test compared with the control sites, both at the bucco-lingual and mesio-distal aspects. The differences between test and controls for the coronal level of osseointegration were smaller than those for resorption. When data from all mesial and distal sites facing an adjacent tooth were collapsed and compared with those opposing an edentulous zone, lower bony crest resorption and deeper residual marginal defects were found at the sites with neighboring teeth. Conclusion: The extraction of teeth adjacent to a socket into which implants were installed immediately after tooth extraction caused more alveolar bone resorption both for the bucco-lingual and at the mesio-distal aspects compared with sites adjacent to a maintained tooth. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It has been reported that titanium-zirconium alloy with 13-17% zirconium (TiZr1317) implants show higher biomechanical stability and bone area percentage relative to commercially pure titanium (cpTi) grade 4 fixtures. Purpose: This study aimed to determine whether the higher stability for TiZr1317 implants is associated with higher mechanical properties of remodeling bone in the areas around the implants. Materials and Methods: This study utilized 36 implants (n=18: TiZr1317, n=18: cpTi), which were placed in the healed ridges of the mandibular premolar and first molar of 12 mini pigs (n=3 implants/animal). After 4 weeks in vivo, the samples were retrieved, and resin-embedded histologic sections of approximately 100μm in thickness were prepared. In order to determine the nanomechanical properties, nanoindentation (n=30 tests/specimen) was performed on the bone tissue of the sections under wet conditions with maximum load of 300μN (loading rate: 60μN/s). Results: The mean (±standard deviation) elastic modulus (E) and hardness (H) for the TiZr1317 group were 2.73±0.50GPa and 0.116±0.017GPa, respectively. For the cpTi group, values were 2.68±0.51GPa and 0.110±0.017GPa for E and H, respectively. Although slightly higher mechanical properties values were observed for the TiZr1317 implants relative to the cpTi for both elastic modulus and hardness, these differences were not significant (E=p>0.75; H=p>0.59). Conclusions: The titanium-zirconium alloy used in this study presented similar degrees of nanomechanical properties to that of the cpTi implants. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The present case describes an inferior alveolar nerve lateralization for implant placement that caused mandible fracture a few days after surgery. CLINICAL REPORT: In this case, a 56-year-old female patient who had a severely atrophied jaw and showing bone height less than 7 mm from the bone crest and the mandibular canal was submitted to surgery lateralization of the inferior alveolar conducted with piezzo. Even with all postoperative care, the patient suffered an incomplete fracture of the mandible a few days after lateralization of the inferior alveolar nerve for implant placement. The patient was treated with soft diet and medications for pain and antibiotics, besides removing the implant associated with the fracture. CONCLUSION: It is suggested that this procedure may be conducted in 2 operative periods: firstly, the lateralization of the inferior alveolar; and secondly, after a period of 3 months, the implant placement in a situation of more bone stability. Copyright © 2013 by Mutaz B. Habal, MD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate stress distribution of the peri-implant bone by simulating the biomechanical influence of implants with different diameters of regular or platform switched connections by means of 3-dimensional finite element analysis. Five mathematical models of an implant-supported central incisor were created by varying the diameter (5.5 and 4.5 mm, internal hexagon) and abutment platform (regular and platform switched). For the cortical bone, the highest stress values (rmax and rvm) were observed in situation R1, followed by situations S1, R2, S3, and S2. For the trabecular bone, the highest stress values (rmax) were observed in situation S3, followed by situations R1, S1, R2, and S2. The influence of platform switching was more evident for cortical bone than for trabecular bone and was mainly seen in large platform diameter reduction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Dental implants, indicated for re-establishing both mastigatory and aesthetic functions, can be placed in the sockets immediately after tooth extraction. Most studies investigate the anterior and upper regions of the dental arch, whereas few examine longitudinal appraisal of immediate implant installation in the mandibular molar region. Objective: The aim of this retrospective study was to evaluate the success rate of immediate dental implants placement in mandibular molars within a follow-up period as long as 8 years. Materials and methods: Seventy-four mandibular molar implants after non-traumatic tooth extraction between 2002 and 2008 were examined in the study. All implants were evaluated radiographically immediately after prosthesis placement, 1 year after implantation, and by the end of the experimental period, in 2010. Clinical evaluation was done according to [Albrektsson et al. (1986) The International Journal of Oral & Maxillofacial Implants, 1, 11-25] success criteria for marginal bone loss. The mean bone losses, calculated as the difference between the final evaluation measures and those taken by the end of the first year of implant, were compared using Kruskal-Wallis test with a significance level of 5%. Results: All implants presented clinical and radiographic stable conditions, that is, 100% success rate. Significant bone loss was not found between final evaluation and that of the first functional year (P > 0.05). Conclusion: Immediate implant placement of mandibular molars proved to be a viable surgical treatment given the high success rate up to 8 years after implantation. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution in implants of regular platforms and of wide diameter with different sizes of hexagon by the 3-dimensional finite element method. We used simulated 3-dimensional models with the aid of Solidworks 2006 and Rhinoceros 4.0 software for the design of the implant and abutment and the InVesalius software for the design of the bone. Each model represented a block of bone from the mandibular molar region with an implant 10 mm in length and different diameters. Model A was an implant 3.75 mm/regular hexagon, model B was an implant 5.00 mm/regular hexagon, and model C was an implant 5.00 mm/ expanded hexagon. A load of 200 N was applied in the axial, lateral, and oblique directions. At implant, applying the load (axial, lateral, and oblique), the 3 models presented stress concentration at the threads in the cervical and middle regions, and the stress was higher for model A. At the abutment, models A and B showed a similar stress distribution, concentrated at the cervical and middle third; model C showed the highest stresses. On the cortical bone, the stress was concentrated at the cervical region for the 3 models and was higher for model A. In the trabecular bone, the stresses were less intense and concentrated around the implant body, and were more intense for model A. Among the models of wide diameter (models B and C), model B (implant 5.00 mm/regular hexagon) was more favorable with regard to distribution of stresses. Model A (implant 3.75 mm/regular hexagon) showed the largest areas and the most intense stress, and model B (implant 5.00 mm/regular hexagon) showed a more favorable stress distribution. The highest stresses were observed in the application of lateral load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and Ca and P were present for the RBMa and hybrid surfaces. Following 2 weeks in vivo, no significant differences were observed for torque, bone-to-implant contact, and bone-area fraction occupied measurements. Newly formed woven bone was observed in proximity with all surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The retaining screw of the implant-supported dental prosthesis is the weakest point of the crown/implant system. Furthermore, crown height is another important factor that may increase the lever arm. Therefore, the aim of this study was to assess the stress distribution in implant prosthetic screws with different heights of the clinical crown of the prosthesis using the method of three-dimensional finite element analysis. Three models were created with implants (3.75 mm × 10 mm) and crowns (heights of 10, 12.5 and 15 mm). The results were visualised by means of von Mises stress maps that increased the crown heights. The screw structure exhibited higher levels of stresses in the oblique load. The oblique loading resulted in higher stress concentration when compared with the axial loading. It is concluded that the increase of the crown was damaging to the stress distribution on the screw, mainly in oblique loading. © 2013 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of extensive pathologic lesions in the jaw, most of the time, can generate rehabilitation problems to the patient. The solid ameloblastoma is a locally invasive odontogenic tumor with a high recurrence rate. Its treatment is aggressive and accomplished through resection with safety margin. The criterion standard for reconstruction is autogenous bone, but it can provide a high degree of resorption, causing inconvenience to the patient because of lack of rehabilitative option. This study aimed to describe a patient with ameloblastoma treated through resection and reconstruction with autogenous bone graft, in which, after an extensive resorption of the graft was made, a modified bar was applied to support a prosthetic implant overdenture. Copyright © 2013 by Mutaz B. Habal, MD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microorganisms from the oral cavity may settle at the implant-abutment interface (IAI). As a result, tissue inflammation could occur around these structures. The databases MEDLINE/PubMed and PubMed Central were used to identify articles published from 1981 through 2012 related to the microbial colonization in the implant-abutment gap and its consequence in terms of crest bone loss and osseointegration. The following considerations could be put forward, with respect to the clinical importance of IAI: (a) the space present at the IAI seems to allow bacterial leakage to occur, in spite of the size of this space; (b) bacterial leakage seems to occur at the IAI, irrespective of the type of connection. More studies are necessary to clarify the relationship between leakage at IAI and abutment connection designs; (c) losses at the peri-implant bone crests cannot be related to the IAI size, since few studies have shown no relationship. Also, the microbial leakage at the IAI cannot be related to the bone crest loss, since there are no articles reporting this relationship; remains controversial the influence of the IAI position on the bone crest losses. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 1321-1328, 2013. Copyright © 2013 Wiley Periodicals, Inc.