201 resultados para Axial Length


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to estimate genetic parameters for milk yield at 244 days and lactation length in graded buffalo cows at the El Cangre Cattle Genetic Enterprise. Data were gathered from 2575 lactations, 1377 buffalo cows, 37 milking units and between 2002-2009 calving years. It was employed the Restricted Maximum Likelihood method (REML) for estimating (co) variance components with multi trait model. Average of milk yield at 244 days and lactation length were 864 kg and 240 days, respectively. Heritability was 0.15 for milk yield and 0.13 for lactation length. Genetic correlation between these traits was 0.63. It was concluded that it is necessary to intensify selection and to increase control of the information of the genetic herds to obtain high precision in the estimates and therefore, obtain bigger genetic progress in of this species in our country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our hypothesis was that increasing the length of an estradiol and progesterone (P4) timed artificial insemination (TAI) protocol would improve pregnancy per artificial insemination (P/AI). Lactating Holstein cows (n = 759) yielding 31 +/- 0.30 kg of milk/d with a detectable corpus luteum (CL) at d - 11 were randomly assigned to receive TAI (d 0) following 1 of 2 treatments: (8d) d - 10 controlled internal drug release (CIDR) and 2.0 mg of estradiol benzoate, d - 3 = PGF(2 alpha) (25 mg of dinoprost tromethamine), d - 2 = CIDR removal and 1.0 mg of estradiol cypionate, d 0 = TAI; or (9d) d - 11 = CIDR and estradiol benzoate, d -4 = PGF(2 alpha), d -2 CIDR removal and estradiol cypionate, d 0 TAI. Cows were considered to have their estrous cycle synchronized in response to the protocol by the absence of a CL at artificial insemination (d 0) and presence of a CL on d 7. Pregnancy diagnoses were performed on d 32 and 60. The ovulatory follicle diameter at TAI (d 0) did not differ between treatments (14.7 +/- 0.39 vs. 15.0 +/- 0.40 mm for 8 and 9 d, respectively). The 9d cows tended to have greater P4 concentrations on d 7 in synchronized cows (3.14 +/- 0.18 ng/mL) than the 8d cows (3.05 +/- 0.18 ng/mL). Although the P/AI at d 32 [45 (175/385) vs. 43.9% (166/374) for 8d and 9d, respectively] and 60 [38.1 (150/385) vs. 40.4% (154/374) for 8d and 9d, respectively] was not different, the 9d cows had lower pregnancy losses [7.6% (12/166)] than 8d cows [14.7% (25/175)]. The cows in the 9d program were more likely to be detected in estrus [72.0% (269/374)] compared with 8d cows [62% (240/385)]. Expression of estrus improved synchronization [97.4 (489/501) vs. 81% (202/248)], P4 concentrations at d 7 (3.22 +/- 0.16 vs. 2.77 +/- 0.17 ng/mL), P/AI at d 32 [51.2 (252/489) vs. 39.4% (81/202)], P/AI at d 60 [46.3 (230/489) vs. 31.1% (66/202)], and decreased pregnancy loss [9.3 (22/252) vs. 19.8% (15/81)] compared with cows that did not show estrus, respectively. Cows not detected in estrus with small (<11 mm) or large follicles (>17 mm) had greater pregnancy loss; however, in cows detected in estrus, no effect of follicle diameter on pregnancy loss was observed. In conclusion, increasing the length of the protocol for TAI increased the percentage of cows detected in estrus and decreased pregnancy loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo nesta pesquisa consiste em fazer um trabalho de prevenção junto às instituições APAE (Associação de Pais e Amigos de Excepcionais) e ASIN (Associação de síndrome de Down), ambas de São José dos Campos e ASPAD (Associação de Pais e Amigos de síndrome de Down) de Jacareí, orientando e avaliando sobre a presença ou não da instabilidade atlanto-axial (IAA), assim como verificar a prevalência dessa anormalidade nesses indivíduos. Foram convidados a participar do projeto todos os indivíduos das três instituições de assistência à SD, tendo formado uma amostra com 68 indivíduos, com idades entre 2 a 34 anos, sendo 39 do sexo masculino e 29 do feminino. Foram realizadas radiografias da coluna cervical nas posições de extensão, flexão e neutra, para as quais todos os responsáveis assinaram termo de consentimento. A verificação da IAA foi feita pela análise da distância atlanto-odontóide (DAO), utilizando o programa Radiocef, com uma ferramenta criada para isso. A DAO foi analisada nas três incidências, e era considerada a presença de IAA desde que o indivíduo apresentasse valores ?4,5mm em pelo menos uma dessas posições. Após a realização dos testes estatísticos e análise dos resultados, concluímos que a prevalência de IAA foi de 22,1% dos indivíduos, com valores DAO entre 4,5 e 8,83mm, tendo sido mais prevalente nos indivíduos do sexo masculino do que feminino, assim como nas crianças do que nos jovens e adultos. Foi possível verificar também que, a posição de flexão apresentou maior prevalência de IAA, mas que ela não deve sobrepor às posições de extensão e neutra, pois pode omitir casos ausentes em flexão, mas presentes nas outras posições. Dessa forma, foi realizado o trabalho de prevenção com a avaliação da IAA por meio da realização dos exames radiográficos em que os laudos... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The length-weight relationships (LWRs) are described for 29 fish species in the region of the Tucurui Reservoir, located in the Tocantins/Araguaia Basin, northern Brazil. Fishes in fourteen sites were sampled seasonally for 10 years, from 2001 to 2010. Significant differences between sexes were found for two species, while 27 species had similar LWRs for males and females. The relationship of standard length and total length is presented for all species as well as the minimum and average size of reproductive females and seasonality of occurrence. No information on LWRs of these 29 species was heretofore available in FishBase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When materials for application in aircraft structural components are studied, it must be considered that they will be submitted to cyclic loading, and this is an important parameter to design the study in fatigue life of the materials. Whereas, for example, a landing gear operation, the study of fatigue life and corrosion in the materials used in it is essential, especially when you want to use new techniques for surface treatments. The objective is to study the influence of surface treatment of immersion ion implantation nitrogen plasma, in axial fatigue of Stainless steel 15-5 PH in 39-42 HRC condition. Stainless steel 15-5 PH was tested in axial fatigue and corrosion in salt spray. It was also performed microindentation tests, optical microscopy for microstructural analysis and scanning electron microscopy for fractographic analysis. It was observed that the 3IP had no effect on the thickness of the material and not the hardness of it, and still provided a significant increase in fatigue life of the material

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the time spent for direct (DBB - direct bracket bonding) and indirect (IBB - indirect bracket bonding) bracket bonding techniques. The time length of laboratorial (IBB) and clinical steps (DBB and IBB) as well as the prevalence of loose bracket after a 24-week follow-up were evaluated. METHODS: Seventeen patients (7 men and 10 women) with a mean age of 21 years, requiring orthodontic treatment were selected for this study. A total of 304 brackets were used (151 DBB and 153 IBB). The same bracket type and bonding material were used in both groups. Data were submitted to statistical analysis by Wilcoxon non-parametric test at 5% level of significance. RESULTS: Considering the total time length, the IBB technique was more time-consuming than the DBB (p < 0.001). However, considering only the clinical phase, the IBB took less time than the DBB (p < 0.001). There was no significant difference (p = 0.910) for the time spent during laboratorial positioning of the brackets and clinical session for IBB in comparison to the clinical procedure for DBB. Additionally, no difference was found as for the prevalence of loose bracket between both groups. CONCLUSION: the IBB can be suggested as a valid clinical procedure since the clinical session was faster and the total time spent for laboratorial positioning of the brackets and clinical procedure was similar to that of DBB. In addition, both approaches resulted in similar frequency of loose bracket.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the association between serum levels of 25(OH) vitamin D-3 with midupper arm muscle circumference (MUAMC), handgrip strength and length of hospital stay (LOS) after hip fracture.Methods: In total, 102 consecutive patients with hip fracture over the age of 65 were admitted to the orthopedic unit and prospectively evaluated. All of the patients were treated according to specific protocols depending on the type of fracture. Anthropometric measurements and handgrip strength were performed, and blood samples were taken for serum biochemistry and 25(OH) vitamin D-3 analysis within the first 72 h of admission. All of the patients were followed during their hospital stay, and the length of stay was recorded.Results: Of the patients, two were excluded because of pathologic fractures. In total, 100 patients with a mean age of 80 +/- 7 y were included in the analysis. Among these patients, 73% were female, and 37% had vitamin D deficiency. The median LOS was 7 (5-11) d. Patients with vitamin D deficiency had lower handgrip strength in univariate analysis. In the multiple linear regression analysis with robust standard error, serum vitamin D levels adjusted by age and sex were associated with handgrip strength but not with MUAMC and LOS after hip fracture.Conclusions: In conclusion, vitamin D serum levels were associated with handgrip strength but not with muscle mass or length of hospital stay after hip fracture. (C) 2015 Elsevier Inc. All rights reserved.