21 resultados para stress testing
Resumo:
The electrocardiographic effects of dobutamine stress testing (10 to 40 mu g/kg/minute) were investigated in five conscious healthy dogs. We studied the changes in the duration and amplitude of P wave, PR interval, duration of QRS complex, R wave amplitude, QT interval, and heart rate. Development of arrhythmias and ST segment abnormalities were also recorded. It was observed that dobutamine significantly affects atrioventricular-nodal conduction and total electrical systole time at higher infusion rates. Only a single episode of sustained ventricular tachycardia was observed, which was promptly restored to sinus rhythm shortly after dobutamine infusion was discontinued. No ST segment abnormalities were detected. Dobutamine stress testing was concluded to play a role in some ECG parameters at higher infusion rates.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
FUNDAMENTO: A Tolerância ao Esforço Físico (TEF) é uma medida de condicionamento cardiorrespiratório. A capacidade aeróbica é reduzida na Insuficiência Cardíaca (IC), embora não haja dados disponíveis sobre esse parâmetro em animais com disfunção ventricular e sem sinais de IC. OBJETIVO: Avaliar a TEF em ratos com disfunção ventricular diastólica isolada ou associada com disfunção sistólica induzida pela Estenose da Aorta ascendente (EAo). MÉTODOS: Ratos Wistar machos jovens (20-30 dias de idade) foram divididos em Grupo Controle (GC, n = 11) e Grupo EAo (n = 12). Os animais foram avaliados em 6 e 18 semanas após a cirurgia para EAo. O teste ergométrico foi feito até a exaustão e foram avaliadas a velocidade da esteira e a concentração de lactato [LAC] no limiar de lactato, velocidade da esteira e [LAC] na exaustão, e tempo total do teste. RESULTADOS: Dados ecocardiográficos revelaram remodelação do átrio esquerdo e hipertrofia concêntrica ventricular esquerda em 6 e 18 semanas. A fração de encurtamento endocárdico mostrou-se maior no grupo EAo do que no GC em 6 e 18 semanas. A fração de encurtamento da parede média mostrou-se maior no grupo EAo do que no GC em 6 semanas. O índice cardíaco mostrou-se semelhante no GC e no grupo EAo em 6 e 18 semanas, tendo diminuído entre 6-18 semanas em ambos os grupos. A razão entre a onda E a onda A foi maior no GC do que no grupo EAo em ambos os períodos e não se alterou em ambos os grupos entre a semana 6 e a semana 18. Os parâmetros do teste de esforço na esteira foram semelhantes nos dois grupos tanto na semana 6 quanto na semana 18. CONCLUSÃO: Embora a EAo promova a disfunção diastólica isolada ou associada à disfunção sistólica, em 6 ou 18 semanas, ela não é suficiente para alterar a tolerância ao esforço físico.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 x 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 x 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 x 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.
Resumo:
The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the Sao Jose dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. Materials and and methods: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10) and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. Results: The fracture test presented the following averages and standard deviation: G1 (45.63 +/- 8.77), G2 (49.98 +/- 7.08), G3 (43.84 +/- 5.52), G4 (47.61 +/- 7.23). Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. Conclusions: The experimental post (original and modified versions) presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008PA/CEP).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To study the role played by 5-HT mechanisms of the MRN, behavioural and physiological parameters were presently measured in rats having either electrolytic or 5,7-dihydroxytryptamine (5,7-DHT) lesion of the MRN made 7 days before testing. Half the animals were submitted to 2-h restraint 24 h before the test. In the elevated plus-maze, the electrolytic lesion increased the percentage of open-arm entries and of time spent on open arms - an anxiolytic effect - in both restrained and nonrestrained rats. The neurotoxic lesion had a similar effect, but only on restrained rats. Restraint had anxiogenic effect. The electrolytic lesion increased transitions between the light and dark compartments and the time spent in the bright compartment of the light-dark box in both restrained and nonrestrained rats. The neurotoxic lesion only increased bright time in restrained rats. The incidence, number and size of gastric ulcers were increased by either the electrolytic or the neurotoxic lesion in both restrained and nonrestrained animals. Both types of lesion depleted 5-HT in the hippocampus in restrained and nonrestrained rats. Restraint increased 5-HT levels. These results implicate 5-HT mechanisms of the median raphe nucleus in the regulation of anxiety and in the genesis of gastric stress ulcers. (C) 2001 Elsevier B.V. All rights reserved.
Resumo:
A new protocol using 3-h fast animal for intestinal motility test was developed in our laboratory aiming the 3R's concept to reduce the stress of animals. Our results may aid in formulating recommendations that can be included in revised guidelines with regard to fasting time of mice.
Resumo:
Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare.
Resumo:
Maxillary defects resulting from cancer, trauma, and congenital malformation affect the chewing efficiency and retention of dentures in these patients. The use of implant-retained palatal obturator dentures has improved the self-esteem and quality of life of several subjects. We evaluate the stress distribution of implant-retained palatal obturator dentures with different attachment systems by using the photoelastic analysis images. Two photoelastic models of the maxilla with oral-sinus-nasal communication were fabricated. One model received three implants on the left side of the alveolar ridge (incisive, canine, and first molar regions) and the other did not receive implants. Afterwards, a conventional palatal obturator denture (control) and two implant-retained palatal obturator dentures with different attachment systems (O-ring; bar-clip) were constructed. Models were placed in a circular polariscope and a 100-N axial load was applied in three different regions (incisive, canine, and first molar regions) by using a universal testing machine. The results were photographed and analyzed qualitatively using a software (Adobe Photoshop). The bar-clip system exhibited the highest stress concentration followed by the O-ring system and conventional denture (control). Images generated by the photoelastic method help in the oral rehabilitator planning. © 2013 SPIE.