148 resultados para liquid chromatography–mass spectrometry (LC-MS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical®, F. Hoffmann-La Roche Ltd., Switzerland) vs. generic (Lipiblock®, EMS-Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock® revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical® appears to offer a better safety margin than Lipiblock® which, however, compares quite well to other generic formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rocuronium (ROC) is a neuromuscular blocking agent used in surgical procedures which is eliminated primarily by biliary excretion. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of ROC in human plasma. Separation of ROC and IS (verapamil) was performed using an endcapped C-18 column and a mixture of water:acetonitrile:trifluoracetic acid (50:50:0.1, v/v) as mobile phase. Aliquots of 100 mu L of human plasma were extracted at pH 3, using dichloromethane. The lower limit of quantification of 5 ng/mL shows the high sensitivity of this method. Intra- and inter-assay precision (as relative standard deviation) was all <= 14.2% and accuracy (as relative standard error) did not exceed 10.1%. The validated method was successfully applied to quantify ROC concentrations in patients under surgical procedures up to 6 h after the administration of the 0.4-0.9 mg/kg ROC. The pharmacokinetic parameter estimations of ROC showed AUC/dose of 563 mu g min/mL, total clearance of 2.5 mL/min/kg, volume of distribution at steady state of 190 mL/kg and mean residence time of 83 min. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection was developed for the determination of pantoprazole (CAS 102625-70-7) in human plasma using lansoprazole (CAS 103577-45-3) as the internal standard. The analyte and internal standard were extracted from the plasma samples by liquid/liquid extraction using diethyl-ether/dichloromethane (70:30; v/v) and chromatographed on a C-8 analytical column. The mobile phase consisted of acetonitrile/water/methanol (57:25:18; v/v/v) + 10 mmol/l acetic acid + 20 mmol/l ammonium acetate. The method has a chromatographic total run time of 4.5 min and was linear within the range 5.0-5,000 ng/mL. Detection was performed on a triple quadrupole tandem mass spectrometer by Multiple Reaction Monitoring (MRM). The intra- and inter-run precisions calculated from quality control (QC) samples were 4.2% and 3.2%, respectively. The accuracies as determined from QC samples were -5.0% (intra-run) and 2.0% (inter-run). The method herein described was employed in a bioequivalence study of two tablet formulations of pantoprazole.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparative HPLC-UV and LC-MS/MS studies of impurity profiles of a reference sample (Xenical (R), F. Hoffmann La Roche Ltd., Switzerland) vs. generic (Lipiblock (R), EMS Sigma Pharma, a generic drug) were carried out with ethanol extracts of commercial samples. The generic formulation contained higher levels of common impurities as well as a considerable number of impurities not found in the reference product. The detected impurity profile of Lipiblock (R) revealed that it most likely is based on fermentation. Since the effect of the impurities is unknown, at this point fully synthetic Xenical (R) appears to offer a better safety margin than Lipiblock (R) which, however, compares quite well to other generic formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the bioequivalence of 2 tablet formulations of phentolamine (Regitine phentolamine 40 mg tablet formulation by Novartis, Brazil, as test formulation, and Vasomax, phentolamine 40 mg tablet formulation by Schering Plough S.A., Brazil, as reference formulation). Methods: A single 40 mg oral dose of each formulation was administered to 36 male healthy volunteers. The study was conducted after screening, using an open, randomized, 2-period crossover design, a 7-day interval between doses, and wash-out period of at least 4 weeks. Plasma samples for determination of phentolarnine were obtained predose and at intervals over 720 min postdose. Plasma concentrations were quantified by reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS) with positive ion electrospray ionization using multiple reactions monitoring (MRM) method. Precision of the method was evaluated using calibration curves and plasma quality control samples. The subjects were monitored throughout the study. Systolic and diastolic blood pressure and pulse rate measurement were taken predose and at intervals up to 720 min. Tolerance of both products was good. No serious adverse reactions were reported. The pharmacokinetic parameters calculated for both compounds included: AUC((0-720 min)), AUC((0-infinity)), C-max,C- C-max/AUC((0-720 min),) t(max), t(1/2) and k(c). Results: the maximum concentrations reached (Cmax) were compared. Regitine 40 mg formulation C-max geometric mean ratio was 108.29% (90% Cl = 98.58 - 118.96) of Vasomax 40 mg formulation. The areas under the curve (AUC((0-720 min))) were compared. Regitine 40 formulation (AUC((0-720 min)) geometric mean ratio was 102.33% (90% Cl = 97.21 - 107.72) of Vasomax 40 mg formulation. Conclusion: Since the 90% Cl for both Cmax and AUC ratio where inside the 80 to 125% interval proposed by the Food and Drug Administration, it is concluded that Regitine 40 mg tablet is bioequivalent to Vasomax for the rate and extent of absorption.