37 resultados para Waveforms
Resumo:
The Numerical INJection Analysis (NINJA) project is a collaborative effort between members of the numerical relativity and gravitational-wave (GW) astrophysics communities. The purpose of NINJA is to study the ability to detect GWs emitted from merging binary black holes (BBH) and recover their parameters with next-generation GW observatories. We report here on the results of the second NINJA project, NINJA-2, which employs 60 complete BBH hybrid waveforms consisting of a numerical portion modelling the late inspiral, merger, and ringdown stitched to a post-Newtonian portion modelling the early inspiral. In a 'blind injection challenge' similar to that conducted in recent Laser Interferometer Gravitational Wave Observatory (LIGO) and Virgo science runs, we added seven hybrid waveforms to two months of data recoloured to predictions of Advanced LIGO (aLIGO) and Advanced Virgo (AdV) sensitivity curves during their first observing runs. The resulting data was analysed by GW detection algorithms and 6 of the waveforms were recovered with false alarm rates smaller than 1 in a thousand years. Parameter-estimation algorithms were run on each of these waveforms to explore the ability to constrain the masses, component angular momenta and sky position of these waveforms. We find that the strong degeneracy between the mass ratio and the BHs' angular momenta will make it difficult to precisely estimate these parameters with aLIGO and AdV. We also perform a large-scale Monte Carlo study to assess the ability to recover each of the 60 hybrid waveforms with early aLIGO and AdV sensitivity curves. Our results predict that early aLIGO and AdV will have a volume-weighted average sensitive distance of 300 Mpc (1 Gpc) for 10M circle dot + 10M circle dot (50M circle dot + 50M circle dot) BBH coalescences. We demonstrate that neglecting the component angular momenta in the waveform models used in matched-filtering will result in a reduction in sensitivity for systems with large component angular momenta. This reduction is estimated to be up to similar to 15% for 50M circle dot + 50M circle dot BBH coalescences with almost maximal angular momenta aligned with the orbit when using early aLIGO and AdV sensitivity curves.
Resumo:
In this paper an alternative method based on artificial neural networks is presented to determine harmonic components in the load current of a single-phase electric power system with nonlinear loads, whose parameters can vary so much in reason of the loads characteristic behaviors as because of the human intervention. The first six components in the load current are determined using the information contained in the time-varying waveforms. The effectiveness of this method is verified by using it in a single-phase active power filter with selective compensation of the current drained by an AC controller. The proposed method is compared with the fast Fourier transform.
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
Speech signals degraded by additive noise can affects different applications in telecommunication. The noise may degrades the intelligibility of the speech signals and its waveforms as well. In some applications such as speech coding, both intelligibility and waveform quality are important but only intelligibility has been focused lastly. So, modern speech quality measurement techniques such as PESQ (Perceptual Evaluation of Speech Quality) have been used and classical distortion measurement techniques such as Cepstral Distance are becoming unused. In this paper it is shown that some classical distortion measures are still important in applications where speech corrupted by additive noise has to be evaluated.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.
Resumo:
Atualmente, diante das técnicas atuais, a manometria tem sido relegada a plano secundário durante a cateterização cardíaca. No entanto, ainda fornece importantes informações para identificação e avaliação das doenças cardiovasculares. Os dados coletados durante os exames possibilitam a obtenção de variáveis quantitativas e qualitativas, as quais podem ser comparadas aos padrões normais. Os sistemas manométricos são compostos por transdutor, amplificador e registrador, que, em conjunto, devem espelhar com fidelidade a morfologia e os valores das variáveis analisadas. Para atingir esse objetivo, é necessário desempenho adequado de todos os componentes. Se uma determinada informação é de extrema relevância, o operador deve gastar tempo suficiente para obtê-la de maneira inequívoca. Assim, o operador deve estar familiarizado com os sistemas manométricos e com as fontes de erro relacionadas com as técnicas de registro, cateteres, conectores e fluidos. Com os fundamentos analisados neste manuscrito, salientamos que deve ser dispensada atenção às ondas de pressão usadas nas interpretações da fisiopatologia das doenças cardiovasculares.
Resumo:
A proposta deste trabalho é apresentar uma nova metodologia para determinação experimental das capacitancias parasitas do motor de indução trifásico de rotor em gaiola. As capacitancias parasitas fazem parte do circuito equivalente do motor para estudos de interferência eletromagnética causada no motor de indução em modo comum quando ele for acionado por inversor controlado por modulação por largura de pulsos (MLP). Os procedimentos propostos para o desenvolvimento deste novo método consistem em: a) determinação dos parâmetros do circuito equivalente do motor de indução trifásico, em regime permanente, através de ensaio em laboratório; b) estabelecer configurações de ligações entre o inversor MLP e o motor para medições das grandezas de interesse que são as seguintes: tensões de modo comum e de eixo, correntes de fuga e de eixo, através de circuito de medição desenvolvido para este fim; c) calcular os valores das capacitancias parasitas entre estator e carcaça do motor; estator e rotor; rotor e carcaça e de rolamento utilizando a expressão matemática da definição de capacitancia; d) utilizar o software Pspice para simular o sistema motor de indução trifásico, alimentado por inversor MLP, com os circuitos equivalentes em baixas e altas frequências; e) obter as formas de onda características do fenômeno de modo comum.
Resumo:
This paper provides an insight to the trade-off between settling time and power consumption in regulated current mirrors as building parts in micropower current-switching D/A converters. The regulation-loop frequency characteristic is obtained and difficulties to impose a dominant-pole condition to the resulting 2nd-order system are evaluated. Raising pole frequencies in micropower circuits, while meeting consumption requirements, is basically limited by parasitic capacitances. For such cases, an alternative is to impose a twin-pole condition in which design constraints are somewhat relieved and settling slightly improved. Relationships between pole frequencies, transistor geometry and bias are established and design guidelines for regulated current mirrors founded. By placing loop-transistors in either weak or strong inversion, small (W/L) ratios are allowed and stray capacitances reduced. Simulated waveforms suggest a good agreement with theory. The proposed approach applied to the design of a micropower current-mode D/A converter improves both simulated and experimental settling performance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Teaching a course of special electric loads in a continuing education program to power engineers is a difficult task because they are not familiarized with switching topology circuits. Normally, in a typical program, many hours are dedicated to explain the thyristors switching sequence and to draw the converter currents and terminal voltages waveforms for different operative conditions. This work presents teaching support software in order to optimize the time spent in this task and, mainly to benefit the assimilation of the proposed subjects, studying the static converter under different non-ideal operative conditions.
Resumo:
Trade-off between settling time and micropower consumption in MOS regulated cascode current sources as building parts in high-accuracy, current-switching D/A converters is analyzed. The regulation-loop frequency characteristic is obtained and difficulties to impose a dominant-pole condition to the resulting 2nd-order system are discussed. Raising pole frequencies while meeting consumption requirements is basically limited by parasitic capacitances. An alternative is found by imposing a twin-pole system in which design constraints are somewhat relaxed and settling slightly faster. Relationships between pole frequencies, transistor geometry and bias are established. Simulated waveforms obtained with PSpice of designed circuits following a voltage perturbation suggest a good agreement with theory. The proposed approach applied to the design of a micropower current-mode D/A converter improves its simulated settling performance.
Resumo:
The behaviors of an arc-shaped stator induction machine (the sector-motor) and a disc-secondary linear induction motor are analyzed in this work for different values of the frequency. Variable frequency is produced by a voltage source controlled-current inverter which keeps constant the r.m.s. value of the phase current, also assuring a sinusoidal waveform. For the simulations of the machine developed thrust, an equivalent circuit is used. It is obtained through the application of the one-dimensional theory to the modeling. The circuit parameters take into account the end effects, always present is these kind of machines. The phase current waveforms are analyzed for their harmonic contents. Experimental measurements were carried out in laboratory and are presented with the simulations, for comparison.