18 resultados para Showers (Plumbing fixtures)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports the 20-month clinical outcome of the use of 4 zygomatic implants with immediate occlusal loading and reverse planning for the retreatment of atrophic edentulous maxilla after failed rehabilitation with autogenous bone graft reconstruction and maxillary implants. The intraoral clinical examination revealed mispositioned and loosened implants underneath a maxillary complete denture. The panoramic radiograph showed 6 maxillary implants. One implant was displaced into the right maxillary sinus, and the implant anchored in the region of tooth 21 was fractured. The other implants presented peri-implant bone loss. The implants anchored in the regions of teeth 21 to 23 and 11 to 13 were first removed. After 2 months, the reverse planning started with placement of 4 zygomatic fixtures, removal of the implants migrated into the sinus cavity and anchored in the region of tooth 17, and installation of a fixed denture. After 20 months of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. The outcomes of this case confirm that the zygoma can offer a predictable anchorage and support function for a fixed denture in severely resorbed maxillae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the satisfaction of patients rehabilitated with zygomatic fixtures and prosthesis with immediate loading.Materials and Methods: The study selected patients who were rehabilitated with zygomatic implants at the clinic of the Latin American Institute for Dental Research and Education (ILAPEO. Curitiba-PR. Brasil) between 2005 and 2009. The patients were asked to answer a control-questionnaire during their follow-up visits. Data were collected regarding the level of patient satisfaction, reason for dissatisfaction, number of post-operative clinical sessions, and the type of complication. Sixteen patients were selected: 10 females and 6 males.Results: Half of the patients were completely satisfied while the other half were satisfied with some complaints. The complaints were related to hygiene, esthetics, phonetics, and discomfort during chewing. Regarding the post-operative evaluation, 50% of the patients were attended due to the prosthesis (62.5%) and the implant (37.5%).Conclusions: The treatment with zygomatic fixtures is predictable and reliable. The patients were satisfied both with implants and prosthesis. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70: 314-319, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the results of the investigations that were done to identify and to quantify the power quality problems resultant from the actions done to improve the efficiency on electric energy consumption. The efficiencies of several electric devices were evaluated, among them: fluorescent bulb, electronic ballast, soft-starter, temperature controller for showers, dimmer and others. This evaluation allowed to establish a cause/effect analysis of the power quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this Letter we report on a search for long-lived particles that decay into final states with two electrons or photons. Such long-lived particles arise in a variety of theoretical models, such as hidden valleys and supersymmetry with gauge-mediated breaking. By precisely reconstructing the direction of the electromagnetic shower we are able to probe much longer lifetimes than previously explored. We see no evidence of the existence of such long-lived particles and interpret this search as a quasi model-independent limit on their production cross section, as well as a limit on a long-lived fourth generation quark. © 2008 The American Physical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: It has been reported that titanium-zirconium alloy with 13-17% zirconium (TiZr1317) implants show higher biomechanical stability and bone area percentage relative to commercially pure titanium (cpTi) grade 4 fixtures. Purpose: This study aimed to determine whether the higher stability for TiZr1317 implants is associated with higher mechanical properties of remodeling bone in the areas around the implants. Materials and Methods: This study utilized 36 implants (n=18: TiZr1317, n=18: cpTi), which were placed in the healed ridges of the mandibular premolar and first molar of 12 mini pigs (n=3 implants/animal). After 4 weeks in vivo, the samples were retrieved, and resin-embedded histologic sections of approximately 100μm in thickness were prepared. In order to determine the nanomechanical properties, nanoindentation (n=30 tests/specimen) was performed on the bone tissue of the sections under wet conditions with maximum load of 300μN (loading rate: 60μN/s). Results: The mean (±standard deviation) elastic modulus (E) and hardness (H) for the TiZr1317 group were 2.73±0.50GPa and 0.116±0.017GPa, respectively. For the cpTi group, values were 2.68±0.51GPa and 0.110±0.017GPa for E and H, respectively. Although slightly higher mechanical properties values were observed for the TiZr1317 implants relative to the cpTi for both elastic modulus and hardness, these differences were not significant (E=p>0.75; H=p>0.59). Conclusions: The titanium-zirconium alloy used in this study presented similar degrees of nanomechanical properties to that of the cpTi implants. © 2013 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)