45 resultados para METALLIC STENT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Isolated iliac artery aneurysms are rare in the general population (0.03%) and represent 2% of all abdominal aneurysms, and the association with Marfan syndrome is even rarer. We report a Marfan syndrome case with an isolated common iliac artery aneurysm treated by using a modified 'stent-graft sandwich' technique, with preservation of the internal iliac artery perfusion. The modified 'stent-graft sandwich' technique involves building an appropriate proximal neck just in the common iliac artery for fittingly housing two new stent-grafts inside, both deployed simultaneously and each one going to both distal iliac arteries (internal and external).
Resumo:
Background: Limitations of endovascular thoracic aneurym treatment include small, tortuous, or severely calcified iliac Back, arteries. We present our experience with a total laparoscopic access to deploy thoracic endografts.Methods. A total laparoscopic left retrocolic approach was used in all cases. A Dacron conduit was laparoscopically sutured to either the iliac artery or to the aorta directly. The endograft was inserted through this conduit. After graft deployment, the Dacron prosthesis was tunneled to the groin and anastomosed with the femoral artery.Results. The laparoscopic procedure could successfully be performed in 11 patients. In six cases, the aorta was used as all access and in five patients, the iliac arteries were preferred. In one of these cases, the right iliac artery, was used for deployment of the endograft. After successful aorto- or ileo-femoral bypass grafting, all patients had an improvement of their ankle brachial index postoperatively. The mean operative time was almost four hours, including laparoscopy, laparoscopic anastomosis, endograft deployment, and femoral artery anastomosis or profundaplasty.Conclusion: Totally laparoscopic assisted graft implantation in aorta or iliac arteries provides a safe and effective access for the endovascular delivery system. However, further evaluation and long follow-up are necessary to ensure the potential advantages of this technique. It is a less invasive option to overcome access-related problems with thoracic endograft deployment, giving the patient the advantage of a totally minimal invasive procedure. (J Vasc Surg 2010;51:504-8.)
Resumo:
This case report describes a technique that uses a palatal mucosal graft and an acrylic resin postoperative stent in an attempt to increase the layer of keratinized tissue around osseointegrated implants in an atrophic mandible. During second-stage surgery a split-thickness labial flap is reflected and apically repositioned by being sutured onto the periosteum and connective tissue. A palatal mucosal graft is then sutured onto the recipient site. The stent is worn for at least 4 weeks following surgery. This procedure helps to eliminate mobility of the mucosa in the area, deepen the vestibule, and prevent muscle reinsertion. (Int J Periodontics Restorative Dent 2008;28:617-623.)
Resumo:
Background. Severely resorbed mandibles often present a short band of keratinized tissue associated with a shallow vestibule. As a result, prominent muscle insertions are present, especially in the mental region of the mandible. This case report describes the deepening of the vestibular sulcus in an atrophic mandible by combining free gingival grafts harvested from the palate and a postoperative acrylic resin stent screwed on osseointegrated implants placed at the anterior region of the mandible.Study design. During the second-stage surgery, a split-thickness labial flap was reflected and apically sutured onto the periosteum. Two free gingival grafts were obtained and then sutured at this recipient site. A previously custom-made acrylic stent was then screwed onto the most distally positioned implants. To document the procedure's stability over time, a metal ball was placed in the most apical part of the vestibule and standardized cephalometric radiographs were taken before and 6 months after the procedure. Linear measurements of vestibular depths over the observation time were realized using specific software for radiographic analysis.Results. The proposed technique augmented the band of attached masticatory mucosa, deepened the vestibule and prevented the muscle reinsertion. The difference between the 2 measurements of vestibular depths was 9.39 mm (initial 20.88 mm, final 11.49 mm) after a 6-month postoperative period.Conclusion. The technique, in combination with palatal mucosal graft and use of a postoperative stent, decreased the pull of mentalis muscle and provided a peri-implantally stable soft tissue around implants. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: e7-e14)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This clinical report describes a method to reduce the number of clinical sessions for the rehabilitation of implant-supported fixed dentures through a simplified and versatile procedure indicated mainly for immediate loading. According to this method, the immediate implant-supported fixed dentures for edentulous patients can be safely fabricated within 2 days. In this technique, the teeth in the wax are prepared on a base of light-polymerized resin, and both wax teeth and metallic superstructure trials are accomplished at the same session.
Resumo:
Crystalline molybdate thin films were prepared by the complex polymerization method. The AMoO(4) (A = Ca, Sr, Ba) films were deposited onto Si wafers by the spinning technique. The Mo-O bond in the AMoO(4) structure was confirmed by FTIR spectra. X-ray diffraction revealed the presence of crystalline scheelite-type phase. The mass, size, and basicity of A(2+) cations was found to be dependent on the intrinsic characteristics of the materials. The grain size increased in the following order: CaMoO4 < SrMoO4 < BaMoO4. The emission band wavelength was detected at around 576 nm. Our findings suggest that the material's morphology and photoluminescence were both affected by the variations in cations (Ca, Sr, or Ba) and in the thermal treatment.
Resumo:
Plantas dos capins braquiaria brachiaria decumbens Stapf (Prain) , quicuio da Amazonia, (Brachiaria humidicola (Rendle) Schweickerdt), pangola (Digitaria decumbens Stent), jaraguá (Hyphrrhenia rufa (Ness) Stapf), gordura (Melinis minutiflora Pal de Beauv), colonião (Panicum maximum Jacq) e napier (Pennisetwn purpure um Schum) foram cultivadas em solução nutritiva completa contendo, 0,12; 0,48; 1,94; 7,75 e 31,00 mg de fósforo por litro, com o objetivo de determinar os níveis críticos internos e externos de fosforo, e avaliar a eficiência com que absorvem e utilizam o fósforo. Aos setenta e cinco dias as plantas foram coletadas, separadas em caules, folhas, bainhas e raízes. Após secagem a 80ºC, as amostras foram pesadas e analisadas para fósforo na matéria seca. Curvas representativas do peso da matéria seca e da concentração de fósforo na matéria seca em função dos níveis de fosforo da solução nutritiva foram obtidas a partir de dados calculados de equações de regressão. Verificou-se que: - As espécies diferiram quanto à necessidade externa de fósforo, sendo B. humidicola e H. rufa as menos exigentes. Seguiram-se em ordem crescente B. decumbens, M. minutiflora, P. maximum, P. purpureum e D. decumbens. - Os níveis críticos internos de fósforo variaram entre as espécies, sendo maior em D. decumbens (0,38%) que nas demais. Seguiram-se em ordem decrescente B. decumbens (0,32%), B. humidioola (0,26%), M. minutiflora (0,24%), P. maximum (o,24%) e P. purpureum (0,20%). - A eficiência de absorção e utilização, do fósforo foi maior para B. humidicola. Seguiram-se em ordem decrescente P. purpureum, P. maximum, D. decumbens , B. decumbens e M. minutiflora.
Resumo:
The electrochemical behavior of metallic chromium in aqueous solutions containing chloride ions at different pH was studied by means of open-circuit potential vs. time measurements, cyclic voltammetry and electrochemical impedance spectroscopy. The composition of the surface oxides was analyzed by XPS. For solutions with pH<3 the formation of a passive layer occurs via a dissolution/precipitation process while for pH>3 the mechanism changes. XPS analysis revealed that Cr2O3 basically constitutes the passive layer.
Resumo:
The demand by high performance materials that have to support severe service conditions at a reasonable cost has been forcing the powder metallurgy to improve constantly. The most recent and more important innovation in the area is the process of powder injection.Powder injection molding (PIM) is a technology capable of producing a new range of components from powders. This advanced technology overcomes the existent limitations in the forming of products with complex geometry. The process presents countless variations which are used in the industry today. Invariably, it consists of mixing the powders and a thermo-plastic binder, injecting the mass in the mold in the wanted form, debinding, sintering and making optional secondary operations, as for example, machinery.The purpose of this work is to review the metal injection molding techniques and apply the low pressure injection molding process to family of parts using metallic powder with 10 mum particle size. This work also comments the design and construction of a low pressure injection machine and injection molds. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
Multilayered nanostructured films have been widely investigated for electrochemical applications as modified electrodes, including the layer-by-layer (LbL) films where properties such as thickness and film architecture can be controlled at the molecular level. In this study, we investigate the electrochemical features of LbL films of poly (o-methoxyaniline; POMA) and tetrasulfonated phthalocyanines containing nickel (NiTsPc) or copper (CuTsPc). The films displayed well-defined electroactivity, with redox pairs at 156 and 347 mV vs SCE, characteristic of POMA, which allowed their use as modified electrodes for detecting dopamine and ascorbic acid at concentrations as low as 10(-5) M.