137 resultados para Conversor estático


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work deals with the development of a switched-mode power supply circuit based on a Buck topology converter with a Boost Rectifier One-Cycle Control with Power Factor Correction developing, thus, a source of direct current for a module of 50 power LEDs that will be used in a lamp for public street lightning. It is presented, at first, some aspects about the most common technologies used in lamps of public street lightning in Brazil and a comparison with the White LED high power, which is the one that presents itself as the most promising among the existing market. Then it is presented the detailed development of the static converter switched PWM, consisting of a Boost rectifier with power factor correction and methodology of control One-Cycle Control associated with a Buck converter controlled by a PI method that operates as a direct current source . At the end of the simulation results of the circuit through the PSIM software are presented to verify the design behavior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar as queixas relatadas por pacientes portadores de deformidades dentofaciais como fatores motivadores na procura do tratamento ortodôntico-cirúrgico. METODOLOGIA: foram verificados 130 prontuários de pacientes em tratamento no CEDEFACE - Araraquara, apresentando um período pós-operatório mínimo de 6 meses e idade média de 30,9 anos. A classificação dos tipos de deformidades foi realizada por meio de análise das telerradiografias e das fotografias, sendo subdivididas em três grupos, de acordo com suas características de perfil facial. As informações referentes às queixas foram colhidas por meio de questionários e divididas em duas categorias: queixa principal e queixas secundárias. em relação à análise estatística, utilizaram-se medidas de tendência central (média e mediana) e de variabilidade (variação e desvio-padrão) para descrever as variáveis numéricas de idade. As variáveis categóricas de gênero, deformidades dentofaciais e queixas foram descritas através da distribuição de freqüências, com nível de significância de 5%. RESULTADOS: observou-se predominância do gênero feminino, na razão de 2:1. Na maioria das vezes, a deformidade requeria tratamento somente na maxila ou somente na mandíbula. No gênero feminino predominaram as deformidades de perfil convexo (46%); no gênero masculino houve predominância de deformidades de perfil côncavo (48,8%). As queixas principais evidenciaram que o anseio estético é predominante, tanto no gênero feminino quanto no masculino. CONCLUSÃO: os anseios de melhora estética foram predominantes em ambos os gêneros. A maioria dos pacientes também apresentou anseio por melhora funcional. Queixas de dor orofacial foram observadas em metade da casuística, sendo a segunda queixa mais relatada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste estudo foi investigar, em mulheres idosas, o efeito agudo do alongamento estático sobre a taxa de desenvolvimento de força pico (TDFP) e contração voluntária máxima (CVM). A amostra foi composta por 10 mulheres idosas (idade 68,5 ± 7,0 anos; peso 70,9 ± 8,1 kg; estatura 159,4 ± 6,0 cm; índice de massa corporal 28,0 ± 3,8 kg/m²). A TDFP e a CVM foram testadas no exercício Leg Press, antes e após as condições controle ou alongamento (três séries de 30 segundos de alongamento estático do quadríceps femoral), em dois dias diferentes (24 horas de intervalo). A TDFP foi determinada como a inclinação mais íngreme da curva, calculada dentro da janela regular de 20 ms (∆Força/∆Tempo), para os primeiros 200 ms após o início da força muscular. A CVM foi determinada como o maior ponto registrado na tentativa. em cada dia, apenas uma condição foi testada e a ordem de emprego para cada condição foi determinada aleatoriamente. A intensidade do alongamento foi determinada pelo limiar de dor muscular. Quatro avaliações pós-condições (pós-tratamento; 10; 20 e 30 minutos) foram realizadas para acompanhar o comportamento da força muscular. A ANCOVA 2x5, seguida do teste post-hoc de Scheffé, não mostrou interações, condição vs. momento, significativas (P > 0,05) para a TDFP e CVM. em conclusão, séries agudas de alongamento estático para o quadríceps femoral não afetam a capacidade de produzir força muscular rapidamente e máxima de mulheres idosas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors studied the CREEP of 5 amalgam alloys (1 conventional and 4 with high cooper) by the application os static load of 36 MPa in 478 mm specimens, 7 days old. After CREEP test, the samples were included in acrylic resin and Vickers hardness determined by three penetrations for each portion (cervical, medium and occlusal). Samples not submitted to the creep test was used with control. They concluded that no statistic difference was found in creep test but in Vickers test all the studied materials showed different hardness averages. The load application to samples increased the hardness of all the studied materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the design and procedure of a DC-to-AC converter using a ZVS Commutation Cell developed by Barbi and Martins (1991) and applied to the family of DC-to-DC PWM converters. Firstly, we show the cell applied to buck converter. The stages of operation and the main current and voltage equations of the resonant devices are presented. Next, we adapt the converter to the regenerative operation mode. Hence, the full bridge converter at low frequency operation is conected on the DC-to-DC stage (at high frequency) output ends (Seixas, 1993). Commutation of zero voltage for all switches, PWM at constant frequency and neither overvoltage nor additional current stress are observed by digital simulation. The design example and experimental results obtained by prototype rated at 275 V, 1 kW and 40 kHz are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Artes - IA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Artes - IA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)