310 resultados para Controle de qualidade : Serviço público
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Introduction: The quality of life of dentists has worsened over time, due to increased risks of labor and competitiveness in the labor market. However, there are only few studies about it. Objective: Investigate the perception of quality of life of dentists working in public service. Methods: In order to accomplish that, a cross-sectional study survey was conducted with 52 dentists of the professional permanent staff of the Municipal Health Service. The data were collected through structured questionnaire, validated, self-administered, proposed by the World Health Organization (WHO) in its shortened version, WHOQOL-Bref. Descriptive statistics and multiple regression were conducted, taking 95% as the confidence interval that characterizes the sample and the calculation of scores for each domain. Results: There was predominance of female subjects (76.9%) the majority of them aged 25 to 35 years (48.7%). Most professionals consider their quality of life good (82.7%), and were satisfied with their health (71.2%). Considering the measures of central tendency and dispersion, the physical domain (13.8) and Environment (13.8) had the lowest mean scores. All areas affected equally poor quality of life of research participants. The facets that showed the lowest values were the physical environment with 39.71 points and 53.92 points to financial resources. Conclusion: The majority of professionals were satisfied with their health and considered their quality of life good.
Resumo:
OBJETIVO: Avaliar o perfil dos fumantes que procuraram serviço público de cessação do tabagismo. MÉTODOS: Foram avaliados retrospectivamente os dados coletados durante a avaliação para a admissão no programa de cessação do tabagismo do Ambulatório de Tabagismo da Faculdade de Medicina de Botucatu/Universidade Estadual Paulista, na cidade de Botucatu (SP) entre abril de 2003 e abril de 2007. Variáveis demográficas, uso prévio de abordagem comportamental e/ou farmacológica e/ou tratamentos alternativos para o tabagismo, grau de dependência à nicotina e comorbidades foram avaliados em 387 fumantes. RESULTADOS: em nossa casuística, 63% dos tabagistas eram do sexo feminino. A idade média dos sujeitos foi de 50 ± 25 anos. Mais da metade dos fumantes (61%) não tinha cursado o ensino médio, e 66% tinham renda mensal menor que dois salários mínimos. O grau de dependência foi elevado/muito elevado em 59%, médio em 17% e baixo/muito baixo em 24%. Embora 95% dos pacientes apresentavam comorbidades, apenas 35% foram encaminhados ao programa por um médico. Mais da metade (68%) tinha feito pelo menos uma tentativa de cessação, 83% sem um programa de tratamento estruturado. CONCLUSÕES: Os tabagistas que procuraram assistência para cessar o tabagismo apresentaram desvantagem social, dependência à nicotina alta e tentativas anteriores de cessação sem tratamento estruturado. Portanto, a intervenção para o controle do tabagismo deve contemplar as características gerais dos fumantes nos serviços públicos para que seja eficaz.
Resumo:
Contexto: Estudos recentes indicam que a concentração elevada de homocisteína é um fator de risco importante e prevalente para doença vascular aterosclerótica coronariana, cerebral e periférica. Objetivo: Tendo em vista a escassez de informações relacionadas à hiper-homocisteinemia em doença arterial periférica (DAP) no Brasil e as peculiaridades de nossa população, o objetivo deste estudo foi avaliar a frequência de hiper-homocisteinemia em amostra dessa população em um ensaio clínico com indivíduos portadores e não portadores de DAP atendidos em um serviço público brasileiro. Métodos: Foi realizado um estudo ensaio clínico caso-controle com 40 indivíduos portadores de DAP confirmada por Doppler ultrassom (grupo DAP) em comparação com 20 indivíduos voluntários sem DAP (grupo-controle). Resultados: A DAP predominante foi a isquemia crônica de membros (75%). As concentrações plasmáticas medianas de homocisteína de jejum foram significantemente maiores no grupo DAP do que no grupo-controle (16,7 versus 12,9 µmol/L, p = 0,001), tanto nos homens (18,9 versus 14,0 µmol/L, p = 0,005) quanto nas mulheres (13,9 versus 11,2 µmol/L, p = 0,025). Quanto à proporção de indivíduos com hiper-homocisteinemia, observou-se tendência a uma maior frequência no grupo DAP (60%) em relação ao grupo-controle (30%) (p = 0,054). Nos indivíduos com idade inferior a 60 anos foram encontrados valores medianos de homocisteína significantemente mais elevados no grupo DAP (p = 0,041). Conclusões: A hiper-homocisteinemia é um fator de risco importante e foi encontrada em 60% dos indivíduos portadores de DAP atendidos em um serviço público no Brasil.
Resumo:
O profissional de saúde é um ponto-chave para a implementação do Sistema Único de Saúde (SUS). À medida que exerce sua função, o sistema passa do aspecto teórico-conceitual para a prática da atenção. Objetivou-se neste estudo verificar o nível de conhecimento sobre o Sistema Único de Saúde (SUS) dos coordenadores de saúde bucal e cirurgiões-dentistas do serviço público dos 40 municípios da região noroeste do Estado de São Paulo. Utilizou-se um questionário estruturado, autoaplicável, composto de questões referentes aos princípios doutrinários e organizativos do SUS, controle social, financiamento, formação de recursos humanos, atenção e assistência em saúde. Dos entrevistados, 77 (89,5%) não sabiam quem era o responsável pelo planejamento e execução da assistência, 53 (61,6%) não tinham conhecimento de equidade, 46 (53,5%) de fundo de saúde e 45 (52,3%) de controle social. Conclui-se que existe deficiência no conhecimento de determinados assuntos, havendo necessidade de promoção de cursos a respeito da filosofia do SUS.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Qualidade na coleta de dados do feixe de radiação, modelagem por meio do sistema de planejamento de tratamento (SPT) e controle da qualidade do processo envolvido são cruciais à fidedignidade do serviço de radioterapia de forma a contribuir à eficácia do tratamento e segurança do principal ente envolvido no final de toda essa sistemática, o paciente. Para isso foi proposto nesse presente trabalho a coleta de dados do feixe de raios-x de 6MV seguido da introdução desses dados ao SPT para processo de modelagem computacional que teve agregado, a todo esses processos, o controle da qualidade segundo critérios de aceitação
Resumo:
Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Pós-graduação em Odontologia Preventiva e Social - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O objetivo do trabalho foi avaliar diferentes dietas para lagartas de Diatraea saccharalis, com o intuito de obter informações sobre as características biológicas da praga e consequentemente avaliar a qualidade do parasitoide Cotesia flavipes, visando melhorar tecnicamente sua produção massal. Lagartas de 24 horas de idade foram transferidas para tubos (25 lagartas/tubo) contendo dieta artificial com levedura de cerveja e germe de trigo e outra somente com germe de trigo como fonte de proteína. Depois de aproximadamente 15 dias, as lagartas foram retiradas dos tubos e acondicionadas em placas com dieta, sendo observadas lagartas de D. saccharalis não parasitadas e parasitadas para avaliação das características biológicas de D. saccharalis e C. flavipes.nas diferentes dietas. Além da observação das características biológicas de D. saccharalis, foram realizadas medições nas lagartas de 15 dias de idade. Também, massas de pupas de C. flavipes.produzidas em biofábrica foram classificadas em três diferentes tamanhos, sendo pequenas (1,3 a 2,5 cm de comprimento), médias (2,5 a 3,5 cm de comprimento) e grandes (3,5 a 4,0 cm de comprimento). Após a emergência dos adultos foi realizado o parasitismo em lagartas de D. saccharalis, sendo observados o número de machos e fêmeas, tamanho da massa, razão sexual e número de pupas inviáveis. A dieta artificial que contém somente germe de trigo é a mais indicada para criação massal do hospedeiro D. saccharalis para produção em larga escala de C. flavipes. Massas de pupas classificadas como grandes possuem melhor qualidade em criações massais de C. flavipes.
Resumo:
Atualmente, as plantas medicinais movem altos valores financeiros em todo o mundo e representam o tipo de tratamento mais acessível para cerca de 80% da população, principalmente entre os países em desenvolvimento. Entretanto, existe ainda uma falta de conhecimento sobre propriedades químicas, farmacológicas e toxicológicas a fim de assegurar a eficácia e segurança das plantas medicinais. Os critérios de eficácia e segurança de plantas medicinais estão relacionados a qualidade, isto é, as plantas necessitam ser corretamente identificadas, cultivadas e coletadas, devem estar livres de material estranho, partes de outras plantas e contaminações inorgânicas e/ou microbianas. O objetivo deste estudo foi o de elucidar os diferentes processos e padronizações sobre o controle de drogas vegetais, principalmente no Brasil.
Resumo:
OBJETIVO: Avaliação de condições dos equipamentos e dosimetria em setores de tomografia computadorizada utilizando protocolos de cabeça, abdome e coluna lombar em pacientes adultos (em três equipamentos distintos) e pediátricos com até um ano e meio de vida (em um dos equipamentos avaliados). MATERIAIS E MÉTODOS: Foram estimados o índice de dose em tomografia computadorizada e a dose média em cortes múltiplos, em exames com pacientes adultos, em três distintos equipamentos. Ainda foram estimadas as doses na superfície de entrada e as doses absorvidas em exame de cabeça para pacientes adultos e pediátricos em um dos equipamentos avaliados. RESULTADOS: Foram realizados testes de controle de qualidade, mecânicos, demonstrando que os equipamentos satisfazem as especificações de uso estabelecidas pelas normas vigentes. Os resultados da dosimetria mostraram que valores de dose média em cortes múltiplos excederam em até 109,0% os valores de níveis de referência, apresentando consideráveis variações entre os equipamentos avaliados neste estudo. As doses absorvidas obtidas com protocolos pediátricos são inferiores aos de pacientes adultos, apresentando redução de até 51,0% na tireoide. CONCLUSÃO: Neste estudo foram avaliadas as condições de operação de três equipamentos tomográficos, estabelecendo quais parâmetros devem ser trabalhados para a implantação de um programa de controle de qualidade nas instituições onde esta pesquisa foi desenvolvida.